MiniSeq v1.0
Last updated
Last updated
The MiniSeq workflow includes the following functionality.
Preconfigured protocols that support the preparation of small genome, amplicon, targeted enrichment, and RNA sequencing using low library volumes for sequencing.
Automated calculation of sample and buffer volumes.
Automated calculation or display of reagents at every step in the protocol.
Automatic step transition when required.
Automatic placement of samples when necessary.
Automated assignment of QC Pass/Fail, based on user-selected threshold values.
Protocol Type = Sequencing
Next Steps Configuration
Master Step Name = Select Normalization Variation (MiniSeq v1.0)
Step Type = No Outputs
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Column
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Comment
Multiline Text
Instruction Notes
Multiline Text
Read Only
Default = Select a Normalization Variation protocol for each sample.
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Column
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Normalization Variation
Text Dropdown
Required Field
Presets
Standard Normalization
Bead-Based Normalization
AmpliSeq for Illumina Normalization
AmpliSeq Library Equalizer for Illumina Normalization
Default = Standard Normalization
Project
Project Name
Built-in
Protocol Type = Sequencing
Next Steps Configuration
Master Step Name = Create Normalized Library Pool (MiniSeq v1.0)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
Resuspension Buffer (RSB)
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Column
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Final Molarity (nM)
Numeric
Default = 10
Range = 1 To 10
Decimal Places Displayed = 0
Final Volume (uL)
Numeric
Default = 10
Range = 10 To 400
Decimal Places Displayed = 0
Instruction Notes
Multiline Text
Read Only
Default = - Enter in Final Molarity (nM), Final Volume (uL) and Library Molarity (nM) before clicking on calculation button. - Add 10 uL of each 10 nM library to a new microcentrifuge tube.
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Column
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Final Molarity (nM)
Numeric
Derived Sample
Library Molarity (nM)
Numeric
Required Field
Derived Sample
Library (uL)
Numeric
Decimal Places Displayed = 0