RNA Library Prep v1.1
Overview
The RNA Library Prep AmpliSeq for Illumina Comprehensive Panel v3 is part of the AmpliSeq for Illumina Comprehensive Panel protocols that include the following functionality:
- Preconfigured AmpliSeq for Illumina Comprehensive Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of genomic DNA or total RNA using the AmpliSeq for Illumina workflow. 
- Automated calculation of sample and buffer volumes. 
- Automated calculation or display of reagents at every step in the protocol. 
- Automatic step transition when required. 
- Automatic placement of samples when necessary.Automated assignment of QC Pass/Fail, based on user-selected threshold values. 
Protocol 1: RNA Library Prep (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
Protocol Type = Library Prep
Next Steps Configuration

Step 1: Dilute RNA (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
- Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1) 
- Step Type = Standard 
- Derived Sample Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - Desired Concentration (ng/uL) - Numeric - Range = 0 To 1000 - Directions - Multiline Text - Read Only - Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL. 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Derived Sample - Concentration - Numeric - Required Field - Decimal Places Displayed = 2 - Derived Sample - Conc. Units - Text - Required Field - Derived Sample - Input Amount (ng) - Numeric - Decimal Places Displayed = 0 - Derived Sample - Nuclease-free water (uL) - Numeric - Decimal Places Displayed = 2 - Derived Sample - Sample Name - Built-in - Derived Sample - Sample Volume (uL) - Numeric - Decimal Places Displayed = 2 - Derived Sample - Total Volume (uL) - Numeric - Decimal Places Displayed = 2 
 
Step 2: Qubit (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
- Master Step Name = Qubit (AmpliSeq for Illumina v1.1) 
- Step Type = Standard QC 
- Measurement Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - Criteria 1 - Operator - Text - Default = >= - Criteria 1 - Source Data Field - Text - Default = Concentration - Criteria 1 - Threshold Value - Numeric - Criteria 2 - Operator - Text - Default = <= - Criteria 2 - Source Data Field - Text - Default = Concentration - Criteria 2 - Threshold Value - Numeric 
- Step File Placeholders - Log - Automatically attached 
- QC Log File - Automatically attached 
- QC Result File - Automatically attached 
- Upload File - Manually uploaded 
 
- Sample Table - Enable QC Flags = Yes 
- Sample Display Default = Expand 
- Well Sort Order = Row 
- File Column Options - File Column Display = Hide 
- File Attachment Method = Auto 
 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Derived Sample - Concentration - Numeric - Required Field - Decimal Places Displayed = 2 - Derived Sample - Conc. Units - Text - Required Field - Derived Sample - Sample Name - Built-in - Measurement - Concentration - Numeric - Decimal Places Displayed = 2 - Measurement - Conc. Units - Text 
 
Step 3: Dilute RNA (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
- Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1) 
- Step Type = Standard 
- Derived Sample Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - Desired Concentration (ng/uL) - Numeric - Range = 0 To 1000 - Directions - Multiline Text - Read Only - Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL. 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Derived Sample - Concentration - Numeric - Required Field - Decimal Places Displayed = 2 - Derived Sample - Conc. Units - Text - Required Field - Derived Sample - Input Amount (ng) - Numeric - Decimal Places Displayed = 0 - Derived Sample - Nuclease-free water (uL) - Numeric - Decimal Places Displayed = 2 - Derived Sample - Sample Name - Built-in - Derived Sample - Sample Volume (uL) - Numeric - Decimal Places Displayed = 2 - Derived Sample - Total Volume (uL) - Numeric - Decimal Places Displayed = 2 
 
Step 4: Reverse Transcribe (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
- Master Step Name = Reverse Transcribe RNA (AmpliSeq for Illumina v1.1) 
- Step Type = Standard 
- Derived Sample Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
- Reagent Kits - AmpliSeq cDNA Synthesis for Illumina - Supplier = Illumina 
- Catalog Number = 20022654 
- Website = www.illumina.com 
 
 
Automations
Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Placement = Enabled
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
- Placement Pattern = Column 
 
- Destination Containers - 96 well plate 
 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - 5X AmpliSeq cDNA Reaction Mix (uL) - Numeric - Decimal Places Displayed = 1 
 - 10X AmpliSeq RT Enzyme Mix (uL) - Numeric - Decimal Places Displayed = 1 
 - Desired Concentration (ng/uL) - Numeric - Read Only - Nuclease-free water (uL) - Numeric - Decimal Places Displayed = 1 
 - Prep Input Amount (ng) - Numeric - Default = 2 
- Range = 2 To 1000 
 - Prep Input Volume (uL) - Numeric - Decimal Places Displayed = 2 
 - Recommended Prep Input (ng) - Multiline Text - Read Only - Default = Each reaction requires 1-100 ng of DNase-treated total RNA. The recommended input is 10 ng RNA. 
 - Thermal Cycler Program - Text - Read Only - Default = RT 
 - Total Samples - Numeric - Default = 0 
- Decimal Places Displayed = 0 
 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Derived Sample - Concentration - Numeric - Required Field - Decimal Places Displayed = 2 - Derived Sample - Conc. Units - Text - Required Field - Derived Sample - Input Amount (ng) - Numeric - Decimal Places Displayed = 0 - Derived Sample - Sample Name - Built-in - Derived Sample - Total Volume (uL) - Numeric - Decimal Places Displayed = 2 
 
Step 5: Amplify cDNA Targets (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
- Master Step Name = Amplify cDNA Targets (AmpliSeq for Illumina v1.1) 
- Step Type = Standard 
- Derived Sample Generation = Fixed, 2 
- Naming Convention = {InputItemName}_{OutputItemSubsetNumber} 
- Reagent Kits - AmpliSeq Comprehensive Panel v3 for Illumina - Supplier = Illumina 
- Catalog Number = 20019109 
 
- AmpliSeq Library PLUS for Illumina - Supplier = Illumina 
- Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103 
- Website = www.illumina.com 
 
 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - 5X AmpliSeq HiFi Mix (uL) - Numeric - Decimal Places Displayed = 2 - Instructions - Comprehensive Panel v3 - Multiline Text - Default = Add 2 µl 5X AmpliSeq Comprehensive RNA Panel v3 Pool 1 (red cap) to the first well. Add 2 µl 5X AmpliSeq Comprehensive RNA Panel v3 Pool 2 (red cap) to the second well. - Nuclease-free water (uL) - Numeric - Decimal Places Displayed = 2 - Thermal Cycler Program - Text - Default = AMP_RNA 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Project - Project Name - Built-in 
 
Step 6: Partially Digested Amplicons (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
- Master Step Name = Partially Digested Amplicons with Pooling (AmpliSeq for Illumina v1.1) 
- Step Type = Pooling 
- Aliquot Generation = Fixed, 1 
- Naming Convention = {PoolName} 
- Reagent Kits - AmpliSeq Library PLUS for Illumina - Supplier = Illumina 
- Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103 
- Website = www.illumina.com 
 
 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Pooling
- Label Uniqueness = Off 
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
Placement
- Defaults - Well Sort Order = Row 
- Placement Pattern = Column 
 
- Destination Containers - 96 well plate 
 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - Thermal Cycler Program - Text - Default = FUPA 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Queue for Plate Transfer - Text - Default = Transfer Amplicons - Derived Sample - Sample Name - Built-in - Project - Project Name - Built-in 
 
Last updated