RNA Library Prep v1.1

Overview

The RNA Library Prep AmpliSeq for Illumina Immune Repertoire Panel is part of the AmpliSeq for Illumina Immune Repertoire Panel protocols that include the following functionality:

  • Preconfigured AmpliSeq for Illumina Immune Repertoire Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of genomic DNA or total RNA using the AmpliSeq for Illumina workflow.

  • Automated calculation of sample and buffer volumes.

  • Automated calculation or display of reagents at every step in the protocol.

  • Automatic step transition when required.

  • Automatic placement of samples when necessary.

  • Automated assignment of QC Pass/Fail, based on user-selected threshold values.

  • A routing script that allows sequencing of libraries using any Illumina sequencing instrument.

Protocol 1: RNA Library Prep (AmpliSeq for Illumina Immune Repertoire Panel v1.1)

Protocol Type = Library Prep

Next Steps Configuration

Step 1: Dilute RNA (AmpliSeq for Illumina Immune Repertoire Panel v1.1)

  • Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Copy Concentration and Set Sample Volume
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

Calculate Input Amount - RNA
  • Trigger Location = Record Details

  • Trigger Style = Manual button

Copy Desired Concentration
  • Trigger Location = Step

  • Trigger Style = Automatic upon exit

Set Next Step - Advance
  • Trigger Location = Not Used

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

Group of Defaults

Immune Repertoire Panel
  • Directions = If enough RNA is available, dilute to intermediate concentration ~20-1000 ng/uL.

TCR beta-SR Panel
  • Default = If enough RNA is available, dilute to intermediate concentration ~20-1000 ng/uL.

  • Step Data

    • Group of Defaults = Immune Repertoire Panel

    • Master Step Fields

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Desired Concentration (ng/uL)

      Numeric

      Range = 0 To 1000

      Directions

      Multiline Text

      Read Only

      Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL.

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      Concentration

      Numeric

      Required Field

      Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Input Amount (ng)

      Numeric

      Decimal Places Displayed = 0

      Derived Sample

      Nuclease-free water (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Sample Name

      Built-in

      Derived Sample

      Sample Volume (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Total Volume (uL)

      Numeric

      Decimal Places Displayed = 2

Step 2: Qubit (AmpliSeq for Illumina Immune Repertoire Panel v1.1)

  • Master Step Name = Qubit (AmpliSeq for Illumina v1.1)

  • Step Type = Standard QC

  • Measurement Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Assign QC flags (Qubit QC)
  • Trigger Location = Record Details

  • Trigger Style = Manual button

Set Next Step and Copy Concentration
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Criteria 1 - Operator

    Text

    Default = >=

    Criteria 1 - Source Data Field

    Text

    Default = Concentration

    Criteria 1 - Threshold Value

    Numeric

    Criteria 2 - Operator

    Text

    Default = <=

    Criteria 2 - Source Data Field

    Text

    Default = Concentration

    Criteria 2 - Threshold Value

    Numeric

  • Step File Placeholders

    • Log - Automatically attached

    • QC Log File - Automatically attached

    • QC Result File - Automatically attached

    • Upload File - Manually uploaded

  • Sample Table

    • Enable QC Flags = Yes

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • File Column Options

      • File Column Display = Hide

      • File Attachment Method = Auto

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      Concentration

      Numeric

      Required Field

      Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Sample Name

      Built-in

      Measurement

      Concentration

      Numeric

      Decimal Places Displayed = 2

      Measurement

      Conc. Units

      Text

Step 3: Dilute RNA to Final Concentration (AmpliSeq for Illumina Immune Repertoire Panel v1.1)

  • Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Copy Concentration and Set Sample Volume
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

Calculate Input Amount - RNA
  • Trigger Location = Record Details

  • Trigger Style = Manual button

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Copy Desired Concentration
  • Trigger Location = Step

  • Trigger Style = Automatic upon exit

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

Group of Defaults

Immune Repertoire Panel
  • Directions = If enough RNA is available, dilute to intermediate concentration ~20-1000 ng/uL.

TCR beta-SR Panel
  • Default = If enough RNA is available, dilute to intermediate concentration ~20-1000 ng/uL.

  • Step Data

    • Group of Defaults = Immune Repertoire Panel

    • Master Step Fields

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Desired Concentration (ng/uL)

      Numeric

      Range = 0 To 1000

      Directions

      Multiline Text

      Read Only

      Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL.

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      Concentration

      Numeric

      Required Field

      Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Input Amount (ng)

      Numeric

      Decimal Places Displayed = 0

      Derived Sample

      Nuclease-free water (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Sample Name

      Built-in

      Derived Sample

      Sample Volume (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Total Volume (uL)

      Numeric

      Decimal Places Displayed = 2

Step 4: Reverse Transcribe (AmpliSeq for Illumina Immune Repertoire Panel v1.1)

  • Master Step Name = Reverse Transcribe RNA (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

  • Reagent Kits

    • AmpliSeq cDNA Synthesis for Illumina

Automations

Copy Concentration, Total Volume and Input Amount
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

Calculate Input Amount - Immune Repertoire Panel
  • Trigger Location = Record Details

  • Trigger Style = Manual button

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Calculate Input Amount
  • Trigger Location = Not Used

Calculate Input Amount - Focus Panel
  • Trigger Location = Not Used

Calculate Input Amount - Immune Response Panel
  • Trigger Location = Not Used

Calculate Input Amount - Myeloid Panel
  • Trigger Location = Not Used

Calculate Input Amount - TCRbeta-SR
  • Trigger Location = Not Used

Calculate Input Amount - Transcriptome Human Genome Expression Panel
  • Trigger Location = Not Used

Calculate Input Amount- Custom RNA Panel
  • Trigger Location = Not Used

Copy Concentration, Total Volume and Input Amount - Myeloid
  • Trigger Location = Not Used

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Placement = Enabled

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

    • Placement Pattern = Column

  • Destination Containers

    • 96 well plate

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    5X AmpliSeq cDNA Reaction Mix (uL)

    Numeric

    • Decimal Places Displayed = 1

    10X AmpliSeq RT Enzyme Mix (uL)

    Numeric

    • Decimal Places Displayed = 1

    Desired Concentration (ng/uL)

    Numeric

    Read Only

    Nuclease-free water (uL)

    Numeric

    • Decimal Places Displayed = 1

    Prep Input Amount (ng)

    Numeric

    • Default = 2

    • Range = 2 To 1000

    Prep Input Volume (uL)

    Numeric

    • Decimal Places Displayed = 2

    Thermal Cycler Program

    Text

    Read Only

    • Default = RT

    Total Samples

    Numeric

    • Default = 0

    • Decimal Places Displayed = 0

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      Concentration

      Numeric

      Required Field

      Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Input Amount (ng)

      Numeric

      Decimal Places Displayed = 0

      Derived Sample

      Sample Name

      Built-in

      Derived Sample

      Total Volume (uL)

      Numeric

      Decimal Places Displayed = 2

Step 5: Amplify cDNA Targets (AmpliSeq for Illumina Immune Repertoire Panel v1.1)

  • Master Step Name = Amplify cDNA Targets Standard (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

  • Reagent Kits

    • AmpliSeq Immune Repertoire Panel for Illumina

      • Supplier = Illumina

      • Catalog Number = 20024479

    • AmpliSeq Library PLUS for Illumina

      • Supplier = Illumina

      • Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103

Automations

Set Sample Type and Calculate Master Mix - Immune Repertoire Panel
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Copy Desired RNA Conc. & Calculate Master Mix - Custom RNA Pool 1
  • Trigger Location = Not Used

Copy Desired RNA Conc. & Calculate Master Mix - Custom RNA Pool 2
  • Trigger Location = Not Used

Routing cDNA - TCRbeta SR
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Routing Samples - Myeloid Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Routing Samples - TCRbeta SR Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Set Sample Type and Calculate Master Mix - Custom RNA
  • Trigger Location = Not Used

Set Sample Type and Calculate Master Mix - Immune Response Panel
  • Trigger Location = Not Used

Set Sample Type and Calculate Master Mix - TCR beta-SR Panel
  • Trigger Location = Not Used

Set Sample Type and Calculate Master Mix - Myeloid Panel
  • Trigger Location = Not Used

Set Sample Type and Calculate Master Mix - TGx Panel
  • Trigger Location = Not Used

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    5X AmpliSeq HiFi Mix (uL)

    Numeric

    Decimal Places Displayed = 2

    5X AmpliSeq Immune Repertoire Panel (uL)

    Numeric

    Decimal Places Displayed = 1

    Nuclease-free water (uL)

    Numeric

    Decimal Places Displayed = 2

    PCR Cycles

    Text

    Thermal Cycler Program

    Text

    Default = AMP_RNA

    Total Samples

    Numeric

    Default = 0

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Step 6: Partially Digested Amplicons (AmpliSeq for Illumina Immune Repertoire Panel v1.1)

  • Master Step Name = Partially Digested Amplicons (AmpliSeq for Illumina v1.1)

  • Step Type = No Outputs

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Thermal Cycler Program

    Text

    Default = FUPA

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Step 7: Ligate Indexes (AmpliSeq for Illumina Immune Repertoire Panel v1.1)

  • Master Step Name = Ligate Indexes (AmpliSeq for Illumina v1.1)

  • Step Type = Add Labels

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

  • Reagent Kits

    • AmpliSeq Library PLUS for Illumina

      • Supplier = Illumina

      • Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Route AmpliSeq Samples - Immune Repertoire Panel
  • Trigger Location = Step

  • Trigger Style = Automatic upon exit

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - BRCA
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Childhood Cancer Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - CHP v2
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - CP
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Custom DNA Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Focus Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Immune Response Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Myeloid Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples -Transcriptome Human GEx Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Placement = Enabled

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

    • Placement Pattern = Row

  • Destination Containers

    • 96 well plate

Add Labels

  • Label Groups

    • AmpliSeq CD Indexes Set A for Illumina

    • AmpliSeq CD Indexes Set B for Illumina

    • AmpliSeq CD Indexes Set C for Illumina

    • AmpliSeq CD Indexes Set D for Illumina

    • AmpliSeq UD Indexes for Illumina (24 Indexes)

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Thermal Cycler Program

    Text

    Default = LIGATE

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      AmpliSeq Workflow

      Text Dropdown

      Required Field

      Presets

      • Standard Workflow

      • Equalizer Workflow

      Derived Sample

      Sample Name

      Built-in

Last updated

Was this helpful?