RNA Library Prep v1.1

Overview

The RNA Library Prep AmpliSeq for Illumina Immune Response Panel is part of the AmpliSeq for Illumina Immune Response Panel protocols that include the following functionality:

  • Preconfigured AmpliSeq for Illumina Immune Response Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of total RNA using the AmpliSeq for Illumina workflow.

  • Automated calculation of sample and buffer volumes.

  • Automated calculation or display of reagents at every step in the protocol.

  • Automatic step transition when required.

  • Automatic placement of samples when necessary.

  • Automated assignment of QC Pass/Fail, based on user-selected threshold values.

  • There is no extraction protocol in this workflow because the samples are already extracted.

Protocol 1: RNA Library Prep (AmpliSeq for Illumina Immune Response Panel v1.1)

Protocol Type = Library Prep

Next Steps Configuration

Step 1: Dilute RNA (AmpliSeq for Illumina Immune Response Panel v1.1)

  • Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Copy Concentration and Set Sample Volume
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Concentration:: = input.::Concentration:: ; output.::Conc. Units:: = input.::Conc. Units:: ; output.::Sample Volume (uL):: = 5' \
-log {compoundOutputFileLuid0}"
Calculate Input Amount - RNA
  • Trigger Location = Record Details

  • Trigger Style = Manual button

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
        -t true \
        -h false \
        -exp 'output.::Total Volume (uL):: = (output.::Concentration::/step.::Desired Concentration (ng/uL)::) * output.::Sample Volume (uL):: ; \
output.::Nuclease-free water (uL):: = output.::Total Volume (uL):: - output.::Sample Volume (uL):: ; \
output.::Input Amount (ng):: = step.::Desired Concentration (ng/uL):: * output.::Total Volume (uL):: ' \
        -log {compoundOutputFileLuid0}"
Copy Desired Concentration
  • Trigger Location = Step

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Desired Concentration (ng/uL):: = step.::Desired Concentration (ng/uL)::' \
-log {compoundOutputFileLuid0}"
Set Next Step - Advance
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'nextStep = ::ADVANCE::' \
      -log {compoundOutputFileLuid0}"

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Desired Concentration (ng/uL)

    Numeric

    Range = 0 to 1000

    Directions

    Multiline Text

    Read Only

    Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL.

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      Concentration

      Numeric

      Required Field

      Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Input Amount (ng)

      Numeric

      Decimal Places Displayed = 0

      Derived Sample

      Nuclease-free water (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Sample Name

      Built-in

      Derived Sample

      Sample Volume (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Total Volume (uL)

      Numeric

      Decimal Places Displayed = 2

Step 2: Qubit (AmpliSeq for Illumina Immune Response Panel v1.1)

  • Master Step Name = Qubit (AmpliSeq for Illumina v1.1)

  • Step Type = Standard QC

  • Measurement Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Assign QC flags (Qubit QC)
  • Trigger Location = Record Details

  • Trigger Style = Manual button

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {processURI:v2} -u {username} -p {password} script:assignQC -log {compoundOutputFileLuid1} -qcResult {compoundOutputFileLuid2}"
Set Next Step and Copy Concentration
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} script:evaluateDynamicExpression -t false -h false -exp 'nextStep = ::ADVANCE:: ; input.::Concentration:: = output.::Concentration:: ; input.::Conc. Units:: = output.::Conc. Units::' -log {compoundOutputFileLuid0}"

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Criteria 1 - Operator

    Text

    Default = >=

    Criteria 1 - Source Data Field

    Text

    Default = Concentration

    Criteria 1 - Threshold Value

    Numeric

    Criteria 2 - Operator

    Text

    Default = <=

    Criteria 2 - Source Data Field

    Text

    Default = Concentration

    Criteria 2 - Threshold Value

    Numeric

  • Step File Placeholders

    • Log - Automatically attached

    • QC Log File - Automatically attached

    • QC Result File - Automatically attached

    • Upload File - Manually uploaded

  • Sample Table

    • Enable QC Flags = Yes

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • File Column Options

      • File Column Display = Hide

      • File Attachment Method = Auto

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      Concentration

      Numeric

      Required Field

      Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Sample Name

      Built-in

      Measurement

      Concentration

      Numeric

      Decimal Places Displayed = 2

      Measurement

      Conc. Units

      Text

Step 3: Dilute RNA to Final Concentration (AmpliSeq for Illumina Immune Response Panel v1.1)

  • Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Copy Concentration and Set Sample Volume
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Concentration:: = input.::Concentration:: ; output.::Conc. Units:: = input.::Conc. Units:: ; output.::Sample Volume (uL):: = 5' \
-log {compoundOutputFileLuid0}"
Calculate Input Amount - RNA
  • Trigger Location = Record Details

  • Trigger Style = Manual button

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
        -t true \
        -h false \
        -exp 'output.::Total Volume (uL):: = (output.::Concentration::/step.::Desired Concentration (ng/uL)::) * output.::Sample Volume (uL):: ; \
output.::Nuclease-free water (uL):: = output.::Total Volume (uL):: - output.::Sample Volume (uL):: ; \
output.::Input Amount (ng):: = step.::Desired Concentration (ng/uL):: * output.::Total Volume (uL):: ' \
        -log {compoundOutputFileLuid0}"
Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'nextStep = ::ADVANCE::' \
      -log {compoundOutputFileLuid0}"
Copy Desired Concentration
  • Trigger Location = Step

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Desired Concentration (ng/uL):: = step.::Desired Concentration (ng/uL)::' \
-log {compoundOutputFileLuid0}"

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Desired Concentration (ng/uL)

    Numeric

    Range = 0 To 1000

    Directions

    Multiline Text

    Read Only

    Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL.

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      Concentration

      Numeric

      Required Field

      Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Input Amount (ng)

      Numeric

      Decimal Places Displayed = 0

      Derived Sample

      Nuclease-free water (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Sample Name

      Built-in

      Derived Sample

      Sample Volume (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Total Volume (uL)

      Numeric

      Decimal Places Displayed = 2

Step 4: Reverse Transcribe (AmpliSeq for Illumina Immune Response Panel v1.1)

  • Master Step Name = Reverse Transcribe RNA (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

  • Reagent Kits

    • AmpliSeq cDNA Synthesis for Illumina

Automations

Copy Concentration, Total Volume and Input Amount
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \
-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Concentration:: = input.::Concentration:: ; \
output.::Conc. Units:: = input.::Conc. Units:: ; \
output.::Total Volume (uL):: = input.::Total Volume (uL):: ; \
output.::Input Amount (ng):: = input.::Input Amount (ng):: ; \
step.::Desired Concentration (ng/uL):: = input.::Desired Concentration (ng/uL)::' \
-log {compoundOutputFileLuid0}"
Calculate Input Amount - Immune Response Panel
  • Trigger Location = Record Details

  • Trigger Style = Manual button

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t true \
-h false \
-exp 'step.::Prep Input Volume (uL):: = step.::Prep Input Amount (ng):: / step.::Desired Concentration (ng/uL):: ; \
if (step.::Prep Input Volume (uL):: < 7.0) {step.::Nuclease-free water (uL):: = (7.0 - (step.::Prep Input Volume (uL):: + output.::AmpliSeq ERCC RNA Spike-in Volume (uL)::)) * step.::Total Samples::*1.1} else {step.::Nuclease-free water (uL):: = 0} ; \
step.::5X AmpliSeq cDNA Reaction Mix (uL):: = step.::Total Samples:: * 1.1 * 1 ; \
step.::10X AmpliSeq RT Enzyme Mix (uL):: = step.::Total Samples:: * 1.1 * 0.5 ; \
step.::AmpliSeq ERCC RNA Spike-in Mix (uL):: = step.::Total Samples:: * output.::AmpliSeq ERCC RNA Spike-in Volume (uL):: *1.1' \
-log {compoundOutputFileLuid0}"
Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'nextStep = ::ADVANCE::' \
      -log {compoundOutputFileLuid0}"
Calculate Input Amount
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t true \
-h false \
-exp 'step.::Prep Input Volume (uL):: = step.::Prep Input Amount (ng):: / step.::Desired Concentration (ng/uL):: ; \
if (step.::Prep Input Volume (uL):: < 7) {step.::Nuclease-free water (uL):: = (7 - step.::Prep Input Volume (uL)::) * step.::Total Samples::*1.1} else {step.::Nuclease-free water (uL):: = 0} ; \
step.::5X AmpliSeq cDNA Reaction Mix (uL):: = step.::Total Samples:: * 1.1 * 2 ; \
step.::10X AmpliSeq RT Enzyme Mix (uL):: = step.::Total Samples:: * 1.1 * 1' \
-log {compoundOutputFileLuid0}"
Calculate Input Amount - Focus Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t true \
-h false \
-exp 'step.::Prep Input Volume (uL):: = step.::Prep Input Amount (ng):: / step.::Desired Concentration (ng/uL):: ; \
if (step.::Prep Input Volume (uL):: < 7) {step.::Nuclease-free water (uL):: = (7 - step.::Prep Input Volume (uL)::) * step.::Total Samples::*1.1} else {step.::Nuclease-free water (uL):: = 0} ; \
step.::5X AmpliSeq cDNA Reaction Mix (uL):: = step.::Total Samples:: * 1.1 * 2; \
step.::10X AmpliSeq RT Enzyme Mix (uL):: = step.::Total Samples:: * 1.1 * 1' \
-log {compoundOutputFileLuid0}"
Calculate Input Amount - Immune Repertoire Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t true \
-h false \
-exp 'step.::Prep Input Volume (uL):: = step.::Prep Input Amount (ng):: / step.::Desired Concentration (ng/uL):: ; \
if (step.::Prep Input Volume (uL):: < 3.5) {step.::Nuclease-free water (uL):: = (3.5 - step.::Prep Input Volume (uL)::) * step.::Total Samples::*1.1} else {step.::Nuclease-free water (uL):: = 0} ; \
step.::5X AmpliSeq cDNA Reaction Mix (uL):: = step.::Total Samples:: * 1.1 * 1 ; \
step.::10X AmpliSeq RT Enzyme Mix (uL):: = step.::Total Samples:: * 1.1 * 0.5' \
-log {compoundOutputFileLuid0}"
Calculate Input Amount - Myeloid Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t true \
-h false \
-exp 'step.::Prep Input Volume (uL):: = step.::Prep Input Amount (ng):: / step.::Desired Concentration (ng/uL):: ; \
if (step.::Prep Input Volume (uL):: < 3.5) {step.::Nuclease-free water (uL):: = (3.5 - step.::Prep Input Volume (uL)::) * step.::Total Samples::*1.1} else {step.::Nuclease-free water (uL):: = 0} ; \
step.::5X AmpliSeq cDNA Reaction Mix (uL):: = step.::Total Samples:: * 1.1 * 1 ; \
step.::10X AmpliSeq RT Enzyme Mix (uL):: = step.::Total Samples:: * 1.1 * 0.5' \
-log {compoundOutputFileLuid0}"
Calculate Input Amount - TCRbeta-SR
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t true \
-h false \
-exp 'step.::Prep Input Volume (uL):: = step.::Prep Input Amount (ng):: / step.::Desired Concentration (ng/uL):: ; \
if (step.::Prep Input Volume (uL):: < 7) {step.::Nuclease-free water (uL):: = (7 - step.::Prep Input Volume (uL)::) * step.::Total Samples::*1.1} else {step.::Nuclease-free water (uL):: = 0} ; \
step.::5X AmpliSeq cDNA Reaction Mix (uL):: = step.::Total Samples:: * 1.1 * 2 ; \
step.::10X AmpliSeq RT Enzyme Mix (uL):: = step.::Total Samples:: * 1.1 * 1' \
-log {compoundOutputFileLuid0}"
Calculate Input Amount - Transcriptome Human Genome Expression Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t true \
-h false \
-exp 'step.::Prep Input Volume (uL):: = step.::Prep Input Amount (ng):: / step.::Desired Concentration (ng/uL):: ; \
if (step.::Prep Input Volume (uL):: < 3.5) {step.::Nuclease-free water (uL):: = (3.5 - (step.::Prep Input Volume (uL):: + output.::AmpliSeq ERCC RNA Spike-in Volume (uL)::)) * step.::Total Samples::*1.1} else {step.::Nuclease-free water (uL):: = 0} ; \
step.::5X AmpliSeq cDNA Reaction Mix (uL):: = step.::Total Samples:: * 1.1 * 1 ; \
step.::10X AmpliSeq RT Enzyme Mix (uL):: = step.::Total Samples:: * 1.1 * 0.5 ; \
step.::AmpliSeq ERCC RNA Spike-in Mix (uL):: = step.::Total Samples:: * output.::AmpliSeq ERCC RNA Spike-in Volume (uL):: *1.1' \
-log {compoundOutputFileLuid0}"
Calculate Input Amount- Custom RNA Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t true \
-h false \
-exp 'step.::Prep Input Volume (uL):: = step.::Prep Input Amount (ng):: / step.::Desired Concentration (ng/uL):: ; \
if (step.::Prep Input Volume (uL):: < 7) {step.::Nuclease-free water (uL):: = (7 - step.::Prep Input Volume (uL)::) * step.::Total Samples::*1.1} else {step.::Nuclease-free water (uL):: = 0} ; \
step.::5X AmpliSeq cDNA Reaction Mix (uL):: = step.::Total Samples:: * 1.1 * 2; \
step.::10X AmpliSeq RT Enzyme Mix (uL):: = step.::Total Samples:: * 1.1 * 1' \
-log {compoundOutputFileLuid0}"
Copy Concentration, Total Volume and Input Amount - Myeloid
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \
-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Concentration:: = input.::Desired Concentration (ng/uL):: ; \
output.::Conc. Units:: = input.::Conc. Units:: ; \
output.::Total Volume (uL):: = input.::Total Volume (uL):: ; \
output.::Input Amount (ng):: = input.::Input Amount (ng):: ; \
step.::Desired Concentration (ng/uL):: = input.::Desired Concentration (ng/uL)::' \
-log {compoundOutputFileLuid0}"

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Placement = Enabled

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

    • Placement Pattern = Column

  • Destination Containers

    • 96 well plate

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    5X AmpliSeq cDNA Reaction Mix (uL)

    Numeric

    • Decimal Places Displayed = 1

    10X AmpliSeq RT Enzyme Mix (uL)

    Numeric

    • Decimal Places Displayed = 1

    AmpliSeq ERCC RNA Spike-in Mix

    Numeric

    • Default = No

    AmpliSeq ERCC RNA Spike-in Mix (uL)

    Numeric

    • Decimal Places Displayed = 2

    AmpliSeq ERCC RNA Spike-in Mix Lot#

    Numeric

    Desired Concentration (ng/uL)

    Numeric

    Read Only

    Nuclease-free water (uL)

    Numeric

    • Decimal Places Displayed = 1

    Prep Input Amount (ng)

    Numeric

    • Default = 2

    • Range = 2 To 1000

    Prep Input Volume (uL)

    Numeric

    • Decimal Places Displayed = 2

    Recommended Prep Input (ng)

    Multiline Text

    Read Only

    • Default = Each reaction requires 1-100 ng of DNase-treated total RNA. The recommended input is 10 ng RNA.

    Thermal Cycler Program

    Text

    Read Only

    • Default = RT

    Total Samples

    Numeric

    • Default = 0

    • Decimal Places Displayed = 0

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      AmpliSeq ERCC RNA Spike-in Volume (uL)

      Numeric

      • Default = 0

      • Range = 0 To 2

      • Decimal Places Displayed = 2

      Derived Sample

      Concentration

      Numeric

      Required Field

      • Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Input Amount (ng)

      Numeric

      • Decimal Places Displayed = 0

      Derived Sample

      Sample Name

      Built-in

      Derived Sample

      Total Volume (uL)

      Numeric

      • Decimal Places Displayed = 2

Step 5: Amplify cDNA Targets (AmpliSeq for Illumina Immune Response Panel v1.1)

  • Master Step Name = Amplify cDNA Targets Standard (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

  • Reagent Kits

    • AmpliSeq Immune Response Panel for Illumina

    • AmpliSeq Library PLUS for Illumina

      • Supplier = Illumina

      • Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103

Automations

Set Sample Type and Calculate Master Mix - Immune Response Panel
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \
-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Sample Type:: = ::cDNA:: ; \
step.::5X AmpliSeq HiFi Mix (uL):: = 4.0 * step.::Total Samples:: * 1.1 ; \
step.::Nuclease-free water (uL):: = 2.0 * step.::Total Samples:: * 1.1 ; \
step.::5x AmpliSeq Immune Response Panel (uL):: = 2.0 * step.::Total Samples:: * 1.1' \
-log {compoundOutputFileLuid0}"
Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'nextStep = ::ADVANCE::' \
      -log {compoundOutputFileLuid0}"
Copy Desired RNA Conc. & Calculate Master Mix - Custom RNA Pool 1
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Diluted RNA Conc. (ng/uL):: = input.::Desired Final Concentration (ng/uL):: ; \
output.::Master Mix (uL):: = 10 ; \
step.::Total Samples:: = step.::Total Samples:: + 1 ; \
step.::5X AmpliSeq HiFi Mix (uL):: = step.::Total Samples:: *1.1* 4 ; \
step.::5X AmpliSeq Custom RNA Panel (uL):: = step.::Total Samples:: * 1.1 * 4 ; \
output.::RNA Volume (uL):: = 10 / output.::Diluted RNA Conc. (ng/uL):: ; \
if (output.::RNA Volume (uL):: < 10) {output.::Nuclease-free water (uL):: = 20 -(output.::Master Mix (uL):: + output.::RNA Volume (uL)::)}' \
-log {compoundOutputFileLuid0}"
Copy Desired RNA Conc. & Calculate Master Mix - Custom RNA Pool 2
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Diluted RNA Conc. (ng/uL):: = input.::Desired Final Concentration (ng/uL):: ; \
output.::Master Mix (uL):: = 10 ; \
step.::Total Samples:: = step.::Total Samples:: + 1 ; \
step.::5X AmpliSeq HiFi Mix (uL):: = step.::Total Samples:: *1.1* 4.5 ; \
step.::5X AmpliSeq Custom RNA Panel (uL):: = step.::Total Samples:: * 1.1 * 4 ; \
output.::RNA Volume (uL):: = 10 / output.::Diluted RNA Conc. (ng/uL):: ; \
if (output.::RNA Volume (uL):: < 10) {output.::Nuclease-free water (uL):: = 20 -(output.::Master Mix (uL):: + output.::RNA Volume (uL)::)}' \
-log {compoundOutputFileLuid0}"
Routing cDNA - TCRbeta SR
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'Sample Type' \
--FIELD_VALUE 'cDNA' \
--WORKFLOW 'DNA Library Prep AmpliSeq for Illumina TCR beta-SR Panel v1.1' \
--STEP 'Transfer RNA and DNA Amplicons (AmpliSeq for Illumina TCR beta-SR Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Routing Samples - Myeloid Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'Sample Type' \
--FIELD_VALUE 'cDNA' \
--WORKFLOW 'DNA Library Prep AmpliSeq for Illumina Myeloid Panel v1.1' \
--STEP 'Transfer RNA and DNA Amplicons (AmpliSeq for Illumina Myeloid Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' "

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Routing Samples - TCRbeta SR Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'Sample Type' \
--FIELD_VALUE 'cDNA' \
--WORKFLOW 'DNA Library Prep AmpliSeq for Illumina TCR beta-SR Panel v1.1' \
--STEP 'Transfer RNA and DNA Amplicons (AmpliSeq for Illumina TCR beta-SR Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' "

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Set Sample Type and Calculate Master Mix - Custom RNA
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \
-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Sample Type:: = ::cDNA:: ; \
step.::5X AmpliSeq HiFi Mix (uL):: = 4.0 * step.::Total Samples:: * 1.1 ; \
step.::5X AmpliSeq Custom RNA Panel (uL):: = 4.0 * step.::Total Samples:: * 1.1 ; \
step.::Nuclease-free water (uL):: = 2.0 * step.::Total Samples:: * 1.1' \
-log {compoundOutputFileLuid0}"
Set Sample Type and Calculate Master Mix - Immune Repertoire Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \
-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Sample Type:: = ::cDNA:: ; \
step.::5X AmpliSeq HiFi Mix (uL):: = 4.0 * step.::Total Samples:: * 1.1 ; \
step.::5X AmpliSeq Immune Repertoire Panel (uL):: = 4.0 * step.::Total Samples:: * 1.1 ; \
step.::Nuclease-free water (uL):: = 7.0 * step.::Total Samples:: * 1.1' \
-log {compoundOutputFileLuid0}"
Set Sample Type and Calculate Master Mix - Myeloid Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \
-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Sample Type:: = ::cDNA:: ; \
step.::5X AmpliSeq HiFi Mix (uL):: = 4.0 * step.::Total Samples:: * 1.1 ; \
step.::Nuclease-free water (uL):: = 7.0 * step.::Total Samples:: * 1.1' \
-log {compoundOutputFileLuid0}"
Set Sample Type and Calculate Master Mix - TCR beta-SR Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \
-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Sample Type:: = ::cDNA:: ; \
step.::5X AmpliSeq HiFi Mix (uL):: = 4.0 * step.::Total Samples:: * 1.1 ; \
step.::5X AmpliSeq TCR beta-SR Panel (uL):: = 4.0 * step.::Total Samples:: * 1.1 ; \
step.::Nuclease-free water (uL):: = 2.0 * step.::Total Samples:: * 1.1' \
-log {compoundOutputFileLuid0}"
Set Sample Type and Calculate Master Mix - TGx Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \
-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
script:evaluateDynamicExpression \
-t false \
-h false \
-exp 'output.::Sample Type:: = ::cDNA:: ; \
step.::5X AmpliSeq HiFi Mix (uL):: = 4.0 * step.::Total Samples:: * 1.1 ; \
step.::Nuclease-free water (uL):: = 3.0 * step.::Total Samples:: * 1.1' \
-log {compoundOutputFileLuid0}"

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    5X AmpliSeq HiFi Mix (uL)

    Numeric

    Decimal Places Displayed = 2

    AmpliSeq ERCC RNA Companion Panel for Illumina

    Toggle Switch

    Default = No

    AmpliSeq ERCC RNA Companion Panel for Illumina Lot#

    Text

    Nuclease-free water (uL)

    Numeric

    Decimal Places Displayed = 2

    PCR Cycles

    Text

    Thermal Cycler Program

    Text

    Default = AMP_RNA

    Total Samples

    Numeric

    Default = 0

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Step 6: Partially Digested Amplicons (AmpliSeq for Illumina Immune Response Panel v1.1)

  • Master Step Name = Partially Digested Amplicons (AmpliSeq for Illumina v1.1)

  • Step Type = No Outputs

  • Reagent Kits

    • AmpliSeq Library PLUS for Illumina

      • Supplier = Illumina

      • Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'nextStep = ::ADVANCE::' \
      -log {compoundOutputFileLuid0}"

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Thermal Cycler Program

    Text

    Default = FUPA

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Step 7: Ligate Indexes (AmpliSeq for Illumina Immune Response Panel v1.1)

  • Master Step Name = Ligate Indexes (AmpliSeq for Illumina v1.1)

  • Step Type = Add Labels

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

  • Reagent Kits

    • AmpliSeq Library PLUS for Illumina

      • Supplier = Illumina

      • Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'nextStep = ::ADVANCE::' \
      -log {compoundOutputFileLuid0}"
Route AmpliSeq Samples - Immune Response Panel
  • Trigger Location = Step

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Standard Workflow' \
--WORKFLOW 'Standard Workflow AmpliSeq for Illumina Immune Response Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Immune Response Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Equalizer Workflow' \
--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina Immune Response Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Immune Response Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Immune Repertoire Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Standard Workflow' \
--WORKFLOW 'Standard Workflow AmpliSeq for Illumina Immune Repertoire Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Immune Repertoire Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Equalizer Workflow' \
--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina Immune Repertoire Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Immune Repertoire Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - BRCA
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Standard Workflow' \
--WORKFLOW 'Standard Workflow AmpliSeq for Illumina BRCA Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina BRCA Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Equalizer Workflow' \
--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina BRCA Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina BRCA Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Childhood Cancer Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Standard Workflow' \
--WORKFLOW 'Standard Workflow AmpliSeq for Illumina Childhood Cancer Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Childhood Cancer Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Equalizer Workflow' \
--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina Childhood Cancer Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Childhood Cancer Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - CHP v2
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Standard Workflow' \
--WORKFLOW 'Standard Workflow AmpliSeq for Illumina Cancer HotSpot Panel V2 v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Cancer HotSpot Panel V2 v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Equalizer Workflow' \
--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina Cancer HotSpot Panel V2 v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Cancer HotSpot Panel V2 v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - CP
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Standard Workflow' \
--WORKFLOW 'Standard Workflow AmpliSeq for Illumina Comprehensive Panel v3 v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Equalizer Workflow' \
--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina Comprehensive Panel v3 v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Custom DNA Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Standard Workflow' \
--WORKFLOW 'Standard Workflow AmpliSeq for Illumina Custom DNA Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Custom DNA Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Equalizer Workflow' \
--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina Custom DNA Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Custom DNA Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Focus Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Standard Workflow' \
--WORKFLOW 'Standard Workflow AmpliSeq for Illumina Focus Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Focus Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Equalizer Workflow' \
--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina Focus Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Focus Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Myeloid Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Standard Workflow' \
--WORKFLOW 'Standard Workflow AmpliSeq for Illumina Myeloid Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Myeloid Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Equalizer Workflow' \
--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina Myeloid Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Myeloid Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples -Transcriptome Human GEx Panel
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Standard Workflow' \
--WORKFLOW 'Standard Workflow AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS' \
\
--FIELD_NAME 'AmpliSeq Workflow' \
--FIELD_VALUE 'Equalizer Workflow' \
--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.1' \
--STEP 'Clean Up Library (AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.1)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Placement = Enabled

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

    • Placement Pattern = Column

  • Destination Containers

    • 96 well plate

Add Labels

  • Label Groups

    • AmpliSeq CD Indexes Set A for Illumina

    • AmpliSeq CD Indexes Set B for Illumina

    • AmpliSeq CD Indexes Set C for Illumina

    • AmpliSeq CD Indexes Set D for Illumina

    • AmpliSeq UD Indexes for Illumina (24 Indexes)

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Thermal Cycler Program

    Text

    Default = LIGATE

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      AmpliSeq Workflow

      Text Dropdown

      Required Field

      Presets

      • Standard Workflow

      • Equalizer Workflow

      Derived Sample

      Sample Name

      Built-in

Last updated

Was this helpful?