The Standard Workflow AmpliSeq for Illumina BRCA Panel is part of the preconfigured AmpliSeq for Illumina BRCA Panel protocols supporting the preparation of uniquely indexed libraries of genomic DNA using the AmpliSeq for Illumina workflow.
This protocol includes the following:
Preconfigured AmpliSeq for Illumina BRCA Panel protocol that supports the preparation of uniquely indexed libraries of genomic DNA using the AmpliSeq for Illumina workflow.
Automated calculation of sample and buffer volumes.
Automated calculation or display of reagents at every step in the protocol.
Automatic step transition when required.
Automatic placement of samples when necessary.
Automated assignment of QC Pass/Fail, based on user-selected threshold values.
A routing script that allows sequencing of libraries using any Illumina sequencing instrument.
Protocol 1: Standard Workflow (AmpliSeq for Illumina BRCA Panel v1.1)
Protocol Type = Library Prep
Next Steps Configuration
Step 1: Clean Up Library (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Clean Up Library (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Reagent Kits
Automations
Set Next Step - Advance
Trigger Location = Record Details
Trigger Style = Automatic upon exit
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Record Details
Step Data (Master Step Fields)
Step 2: Amplify Library (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Amplify Library (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Reagent Kits
Automations
Count Samples and Calculate Master Mix
Trigger Location = Record Details
Trigger Style = Automatic upon entry
Set Next Step - Advance
Trigger Location = Record Details
Trigger Style = Automatic upon exit
Calculate Total Samples and Calculate Master Mix
Trigger Location = Not Used
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Record Details
Group of Defaults
AmpliSeq for CHS V2
Thermal Cycler Program = AMP
Equalizer Workflow
Thermal Cycler Program = EQUAL
Standard Workflow
Thermal Cycler Program = AMP_7
Step Data
Group of Defaults = Standard Workflow
Master Step Fields
Step 3: Perform Second Clean Up (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Perform Second Clean Up (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Automations
Set Next Step - Advance
Trigger Location = Record Details
Trigger Style = Automatic upon exit
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Record Details
Step Data (Master Step Fields)
Equalizer v1.1
Overview
The Equalizer Workflow AmpliSeq for Illumina BRCA Panel is part of the preconfigured AmpliSeq for Illumina BRCA Panel protocols supporting the preparation of uniquely indexed libraries of genomic DNA using the AmpliSeq for Illumina workflow.
Preconfigured AmpliSeq for Illumina BRCA Panel protocol that supports the preparation of uniquely indexed libraries of genomic DNA using the AmpliSeq for Illumina workflow.
Automated calculation of sample and buffer volumes.
Automated calculation or display of reagents at every step in the protocol.
Automatic step transition when required.
Automatic placement of samples when necessary.
Automated assignment of QC Pass/Fail, based on user-selected threshold values.
A routing script that allows sequencing of libraries using any Illumina sequencing instrument.
Protocol 1: Equalizer Workflow (AmpliSeq for Illumina BRCA Panel v1.1)
Protocol Type = Library Prep
Next Steps Configuration
Step 1: Clean Up Library (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Clean Up Library (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Reagent Kits
Agencourt AMPure XP Beads
Supplier = Thermo
Catalog Number = NC9959336; NC9933872
Automations
Set Next Step - Advance
Trigger Location = Record Details
Trigger Style = Automatic upon exit
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
70% EtOH Prep Date
Date
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Step 2: Amplify Library (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Amplify Library (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Automations
Count Samples and Calculate Master Mix
Trigger Location = Record Details
Trigger Style = Automatic upon entry
Set Next Step - Advance
Trigger Location = Record Details
Trigger Style = Automatic upon exit
Calculate Total Samples and Calculate Master Mix
Trigger Location = Not Used
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Record Details
Group of Defaults
AmpliSeq for CHS V2
Thermal Cycler Program = AMP
Equalizer Workflow
Thermal Cycler Program = EQUAL
Standard Workflow
Thermal Cycler Program = AMP_7
Step Data
Group of Defaults = Equalizer Workflow
Master Step Fields
Field Name
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Step 3: Perform Capture and Clean Up (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Perform Capture and Clean Up (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
AmpliSeq Library Equalizer for Illumina
Supplier = Illumina
Automations
Set Next Step - Advance
Trigger Location = Record Details
Trigger Style = Automatic upon exit
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Record Details
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Step 4: Elute Library (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Elute Library (AmpliSeq for Illumina v1.1)
The Library Prep AmpliSeq for Illumina BRCA Panel is part of the preconfigured AmpliSeq for Illumina BRCA Panel protocols supporting the preparation of uniquely indexed libraries of genomic DNA using the AmpliSeq for Illumina workflow.
This protocol includes the following:
Preconfigured AmpliSeq for Illumina BRCA Panel protocol that supports the preparation of uniquely indexed libraries of genomic DNA using the AmpliSeq for Illumina workflow.
Automated calculation of sample and buffer volumes.
Automated calculation or display of reagents at every step in the protocol.
Automatic step transition when required.
Automatic placement of samples when necessary.
Automated assignment of QC Pass/Fail, based on user-selected threshold values.
A routing script that allows sequencing of libraries using any Illumina sequencing instrument.
Protocol 1: Library Prep (AmpliSeq for Illumina BRCA Panel v1.1)
Protocol Type = Library Prep
Next Steps Configuration
Step 1: Dilute DNA (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Dilute DNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Automations
Copy Concentration and Set Sample Volume
Trigger Location = Record Details
Trigger Style = Automatic upon entry
Calculate Input Amount
Trigger Location = Record Details
Trigger Style = Manual button
Set Next Step - Advance
Trigger Location = Not Used
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Record Details
Step Data (Master Step Fields)
Step 2: Qubit (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Qubit (AmpliSeq for Illumina v1.1)
Step Type = Standard QC
Measurement Generation = Fixed, 1
Automations
Assign QC flags (Qubit QC)
Trigger Location = Record Details
Trigger Style = Manual button
Set Next Step and Copy Concentration
Trigger Location = Record Details
Trigger Style = Automatic upon exit
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Record Details
Step Data (Master Step Fields)
Step 3: Dilute DNA to Final Concentration (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Dilute DNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Automations
Copy Concentration and Set Sample Volume
Trigger Location = Record Details
Trigger Style = Automatic upon entry
Calculate Input Amount
Trigger Location = Record Details
Trigger Style = Manual button
Set Next Step - Advance
Trigger Location = Record Details
Trigger Style = Automatic upon exit
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Record Details
Step Data (Master Step Fields)
Step 4: Amplify Targets (AmpliSeq for Illumina BRCA Panel v1.1)
Master Step Name = Amplify Targets (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Automations
Copy Concentration, Total Volume and Input Amount
Trigger Location = Record Details
Trigger Style = Automatic upon entry
Calculate Prep Input
Trigger Location = Record Details
Trigger Style = Manual button
Set Next Step - Advance
Trigger Location = Record Details
Trigger Style = Automatic upon exit
Calculate Prep Input Volume - AmpliSeq Exome
Trigger Location = Not Used
Copy Concentration, Total Volume and Input Amount - AmpliSeq Exome
Trigger Location = Not Used
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Record Details
Group of Defaults
AmpliSeq CHP V2
Thermal Cycler Program = AMP_CHPV2
BRCA
Recommended Prep Input (ng) = This protocol supports 1-100 ng per pool. The recommended input is 10 ng high-quality DNA per pool.