# Release Notes

Last Updated: December 2024

Release Date: December 2024

These Release Notes describe the key changes to software components for the Clarity LIMS MiSeq i100 Series On Premise Integration Package version 1.0.0.

## Compatibility

Refer to [Compatibility](/clarity-lims/instruments-and-integrations/compatibility.md#miseq-i100-series) under Instruments & Integrations.

## New Features

Features provided with this release of the integration package are as follows.

* Provides integration between the MiSeq i100 Series instrument and on-premise Clarity LIMS.
* Supports creation of planned run with secondary analysis configuration and generation of v2 sample sheet via Illumina Run Manager on instrument.
* Supports automated tracking of the sequencing run and parsing of run metrics for on-premise Clarity LIMS.
* Supports automated tracking of local analysis for analysis status and demultiplexing results.
* New MiSeq i100 Series On-Prem Sequencing v1.0 workflow available from Illumina Preset Protocols v2.10.

## Known Limitations

* Tracks only the analysis configured with the planned run. Does not track analysis requeue or analysis triggered externally with the same planned run.
* The Assign Analysis Configuration Template step does not support pooled libraries.
* The integration does not support --bcl-sampleproject-subdirectories option of BCL Convert.
* The integration does not support pools with samples assigned with Analysis Configuration Templates from different instruments.

## Known Issues

* On the Make Bulk Pool step, the log displays a warning when the Calculate Volume automation is triggered and at least one pool consists of multiple inputs. This issue is caused by the output custom field being reset multiple times at the end of the automation. This issue does not affect the Calculate Volume automation functionality.


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://help.connected.illumina.com/clarity-lims/instruments-and-integrations/miseq-i100/miseqi100-onprem/miseqi100-onprem-v1.0.0/miseqi100-onprem-v1.0.0-release-notes.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.