# Release Notes

Release Date: April 2026

Document Version: 3

These release notes describe the key changes to software components for the Clarity LIMS NextSeq 1000/2000 On-Prem Integration Package v1.1.0.

## Compatibility

Refer to [Compatibility](https://help.connected.illumina.com/clarity-lims/compatibility#nextseq-1000-2000) under Instruments & Integrations.

## New Features

* Merge Reads PF and %PF for Read 1 and Read 2
* Replace cluster density metric with occupancy metric
* Analysis workflow UDF default changed from Generate FastQ to BCL convert

## Defect Repairs

* Events are handled correctly with the correct status
* Bug fixes for log file to reflect actual results
* Clean up unused custom primer UDF
* Accept underscore and hyphen for sample name in sample sheet

## Known Issues

* Sequencing run error triggered by disk space full on instrument causes *RunParameters.xml* to be empty and the run event cannot be processed on Clarity LIMS. This error is unlikely to occur as pre-run checks on the instrument check for sufficient disk space before run is started.

## Limitations

* Does not support analysis requeue.

## Revision History

| **Version** | **Changes**                                                                              |
| ----------- | ---------------------------------------------------------------------------------------- |
| 3           | <ul><li>Updated Compatibility section to reference Compatibility matrix table.</li></ul> |
| 2           | <ul><li>Updated Compatibility section to reference Compatibility matrix table.</li></ul> |
| 1           | <ul><li>Initial release.</li></ul>                                                       |