IPP v2.6

Manual Upgrade

Illumina Preset Protocols (IPP) v2.6 includes changes to some workflows.

This section describes the manual upgrade process from IPP v2.5 to IPP v2.6. If you do not want to upgrade the latest workflow through IPP, then update the workflow configuration manually using the following information.

triangle-exclamation

In Clarity LIMS v6.2, symbolic links for Python 2 and Python 3 have been removed. For existing users upgrading from Clarity LIMS v5.x and v6.x to Clarity LIMS v6.2, Python scripts have to explicitly call Python2 and Python3.

IPP v2.6 supports the following workflows:

  • MiSeq Sequencing v3.2

    • Includes validation to ensure single input in the Denature and Dilute step

  • NovaSeq 6000 v3.8

    • Includes CLPA-enabled automations and scripts in the workflow

  • Illumina COVIDSeq Workflow v1.5

    • Updates the Validate Flowcell Barcode automation in the Load to Flowcell Step of NovaSeq Xp Protocol to support the future flowcell barcode format

    • Updates automation scripts to use Python 3 instead of Python 2

  • CDC Covid 19 RT PCR Workflows

    • Includes the PCR Product LIMSID global field

    • Updates automation scripts to use Python 3 instead of Python 2

  • Infinium HD Methylation Assay Manual v1.2

    • Updates automation scripts to use Python 3 instead of Python 2

  • Infinium HTS Assay Manual v1.2

    • Updates automation scripts to use Python 3 instead of Python 2

  • Infinium LCG Assay Manual v1.2

    • Updates automation scripts to use Python 3 instead of Python 2

  • Infinium XT Assay Manual v1.2

    • Updates automation scripts to use Python 3 instead of Python 2

IPP v2.6 also includes the following workflow changes that do not impact functionality:

  • Routing Automation script update for the various Library Preparation workflows with the following updated workflow versions:

    • Illumina DNA Prep (M) Tagmentation v1.0.6

    • Library Prep Validation v2.3

triangle-exclamation

Users that use Python in their scripts must upgrade to IPP v2.6. For more information, contact Illumina Support.

chevron-rightUpdate MiSeq and NovaSeq 6000 v3 Workflowshashtag

For the MiSeq workflow, refer to . For the NovaSeq 6000 workflow, refer to .

chevron-rightUpdate Automations for Illumina COVIDSeq Workflow v1.4 Workflowhashtag
  1. From Configuration, select the Automation tab.

  2. Under the Step Automation tab, search for the Validate Flowcell Barcode automation.

chevron-rightUpdate CDC Covid 19 RT PCR Workflowshashtag
  1. Create the PCR Product LIMSID global field as follows.

    1. From Configuration, select the Custom Fields tab.

chevron-rightUpdate Infinium Assay Manual Workflowshashtag

This update applies to the following workflows:

  • Infinium HD Methylation Assay Manual v1.2

  • Infinium HTS Assay Manual v1.2

chevron-rightUpdate Existing Library Prep Routing Automation Scripthashtag

This script only needs to be updated if you have the following workflows installed and want to route the artifact to the new MiSeq, NextSeq 500/550, NovaSeq 6000 v3, or NovaSeq 6000Dx workflows:

  • Library Prep Validation

Nextera Mate Pair v1.0.7
  • Nextera Rapid Capture Custom Enrichment v2.0.8

  • Nextera Rapid Capture Custom Enrichment v2.0.8

  • TruSeq ChIP-Seq v1.0.7

  • TruSeq Custom Amplicon (TSCA) v1.0.7

  • TruSeq DNA Exome v2.0.7

  • TruSeq DNA PCR-Free v2.0.7

  • TruSeq Methyl Capture EPIC v2.0.8

  • TruSeq Nano DNA v1.0.7

  • TruSeq RNA Access v2.0.7

  • TruSeq Small RNA v1.0.7

  • TruSeq Stranded mRNA v2.1.7

  • TruSight Tumor 170 v2.0.7

  • Workflow and step renaming to standardize the naming format within workflows for the following:

    • NextSeq 500/550 Sequencing v1.1

    • NovaSeqDx v1.2

    • AmpliSeq Illumina BRCA Panel

      • Equalizer Workflow AmpliSeq for Illumina BRCA Panel v1.1

      • Library Prep AmpliSeq for Illumina BRCA Panel v1.1

      • Standard Workflow AmpliSeq for Illumina BRCA Panel v1.1

    • AmpliSeq Illumina Cancer HotSpot Panel V2

      • Library Prep AmpliSeq for Illumina Cancer HotSpot Panel V2 v1.1

      • Standard Workflow AmpliSeq for Illumina Cancer HotSpot Panel V2 v1.1

    • AmpliSeq Illumina Childhood Cancer Panel

      • DNA Library Prep AmpliSeq for Illumina Childhood Cancer Panel v1.1

      • Equalizer Workflow AmpliSeq for Illumina Childhood Cancer Panel v1.1

    • AmpliSeq Illumina Comprehensive Cancer Panel

      • Equalizer Workflow AmpliSeq for Illumina Comprehensive Cancer Panel v1.1

      • Library Prep AmpliSeq for Illumina Comprehensive Cancer Panel v1.1

    • AmpliSeq Illumina Comprehensive Panel v3

      • DNA Library Prep AmpliSeq for Illumina Comprehensive Panel v3 v1.1

      • Equalizer Workflow AmpliSeq for Illumina Comprehensive Panel v3 v1.1

    • AmpliSeq Illumina Custom DNA Panel

      • Equalizer Workflow AmpliSeq for Illumina Custom DNA Panel v1.1

      • Library Prep AmpliSeq for Illumina Custom DNA Panel v1.1

    • AmpliSeq Illumina Focus Panel

      • DNA Library Prep AmpliSeq for Illumina Focus Panel v1.1

      • Equalizer Workflow AmpliSeq for Illumina Focus Panel v1.1

    • AmpliSeq Illumina Immune Repertoire Panel

      • Equalizer Workflow AmpliSeq for Illumina Immune Repertoire Panel v1.1

      • RNA Library Prep AmpliSeq for Illumina Immune Repertoire Panel v1.1

    • AmpliSeq Illumina Immune Response Panel

      • Equalizer Workflow AmpliSeq for Illumina Immune Response Panel v1.1

      • RNA Library Prep AmpliSeq for Illumina Immune Response Panel v1.1

    • AmpliSeq Illumina Myeloid Panel

      • DNA Library Prep AmpliSeq for Illumina Myeloid Panel v1.1

      • Equalizer Workflow AmpliSeq for Illumina Myeloid Panel v1.1

    • AmpliSeq Illumina TCR beta-SR Panel

      • DNA Library Prep AmpliSeq for Illumina TCR beta-SR Panel v1.1

      • RNA Library Prep AmpliSeq for Illumina TCR beta-SR Panel v1.1

    • AmpliSeq Illumina Transcriptome Human Gene Expression Panel

      • Equalizer Workflow AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.1

      • RNA Library Prep AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.1

  • Update the existing command line as follows.

    Changes to the existing command line are in red.

    bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \ -exp 'if ((input.::Flowcell Type:: == ::SP:: && !output.container.name.matches(::[A-Z0-9]{5}DR[A-Z0-9]{2}::)) { fail(::Invalid Flowcell Barcode. Please verify and try again.::) }; if (input.::Flowcell Type:: == ::S1:: && !output.container.name.matches(::[A-Z0-9]{5}DR[A-Z0-9]{2}::))) { fail(::Invalid Flowcell Barcode. Please verify and try again.::) }; if (input.::Flowcell Type:: == ::S2:: && !output.container.name.matches(::[A-Z0-9]{5}DM[A-Z0-9]{2}::))) { fail(::Invalid Flowcell Barcode. Please verify and try again.::) }; if (input.::Flowcell Type:: == ::S4:: && !output.container.name.matches(::[A-Z0-9]{5}DS[A-Z0-9]{2}::))) { fail(::Invalid Flowcell Barcode. Please verify and try again.::) }; output.::Flowcell Type:: = input.::Flowcell Type::; output.::Loading Workflow Type:: = input.::Loading Workflow Type::'\ -log {compoundOutputFileLuid1}"

  • Select Save.

  • From Configuration, select the Automation tab.

  • Under the Step Automation tab, search for the CovidSEQ: Parse TSV Run Report automation.

  • Update the existing command line from python to python3 as follows.

    Changes to the existing command line are in red.

    /usr/bin/python3/opt/gls/clarity/extensions/conf/covid/parseCovidSeqRunReport.py -u {username} -p {password} -s {stepURI} -f {compoundOutputFileLuid1} -g {compoundOutputFileLuid3}

  • Select Save.

  • Under the Global Fields tab, create a new Submitted Sample field with the following attributes:

    • Name: PCR Product LIMSID

    • Field Type: Text

    • Required Field: No

    • Read Only: No

  • Update the automation as follows.

    1. From Configuration, select the Automation tab.

    2. Under the Step Automation tab, search for the auto placement for 7500 Covid-19 assay automation.

    3. Update the existing command line from python to python3 as follows.

      Changes to the existing command line are in red.

      /usr/bin/python3/opt/gls/clarity/extensions/conf/covid/autoPlaceCovid7500.py -u {username} -p {password} -s {stepURI}

  • Select Save.

  • Infinium LCG Assay Manual v1.2

  • Infinium XT Assay Manual v1.2

  • Update the workflows as follows.

    1. From Configuration, select the Automation tab.

    2. Under the Step Automation tab, search for the Validate BeadChip Barcode automation.

    3. Update the existing command line from python to python3 as follows.

      Changes to the existing command line are in red.

      /usr/bin/python3/opt/gls/clarity/extensions/conf/infinium/verifyBeadChipIDs.py -u {username} -p {password} -s {stepURI}

    4. Select Save.

    Illumina DNA Prep (M) Tagmentation
  • Nextera Mate Pair

  • Nextera Rapid Capture Custom Enrichment

  • Nextera XT DNA

  • TruSeq ChIP-Seq

  • TruSeq DNA Exome

  • TruSeq DNA PCR-Free

  • TruSeq Custom Amplicon (TSCA)

  • TruSeq Methyl Capture EPIC

  • TruSeq Nano DNA

  • TruSeq Small RNA

  • TruSeq Stranded mRNA

  • TruSeq RNA Access

  • TruSeq RNA Exome

  • TruSight Tumor 170

  • Updated the script as follows.

    1. From Configuration, select the Automation tab.

    2. Under the Step Automation tab, search for the Routing script - Normalize Libraries automation for Normalize Libraries 1, Normalize Libraries 2, Normalize Libraries 3, or the Normalize Libraries (TruSight Tumor 170 v2.0.6) master step.

      For Library Prep Validation, this automation is named Routing Script & Register Step Completed.

    3. From the command line, search for --FIELD VALUE 'MiSeq' and update the WORKFLOW and STEP value from v3.1 to v3.2.

      ℹ This update is required if the user wants to route to the MiSeq Sequencing v3.2 workflow that can be installed from IPP v2.6.

    4. Search for --FIELD VALUE 'NextSeq' and update the WORKFLOW and STEP value from v1.0 to v1.1.

      ℹ This update is required if the user wants to route to the NextSeq 500/550 Sequencing v1.1 workflow that can be installed from IPP v2.6.

    5. Search for --FIELD VALUE 'NovaSeq 3.0' and update the WORKFLOW and STEP value from v3.7 to v3.8.

      ℹ This update is required if the user wants to route to the NovaSeq 6000 v3.8 workflow that can be installed from IPP v2.6.

    6. Search for --FIELD VALUE 'NovaSeqDx' and update the WORKFLOW and STEP value from v1.1 to v1.2.

      ℹ This update is required if the user wants to route to the NovaSeq 6000Dx v1.2 workflow that can be installed from IPP v2.6.

    MiSeq Integration v8.2 Manual Upgrade
    NovaSeq 6000 Integration v3.6.0 Manual Upgrade
    RNA Library Prep AmpliSeq for Illumina Childhood Cancer Panel v1.1
  • Standard Workflow AmpliSeq for Illumina Childhood Cancer Panel v1.1

  • Standard Workflow AmpliSeq for Illumina Comprehensive Cancer Panel v1.1
    RNA Library Prep AmpliSeq for Illumina Comprehensive Panel v3 v1.1
  • Standard Workflow AmpliSeq for Illumina Comprehensive Panel v3 v1.1

  • Standard Workflow AmpliSeq for Illumina Custom DNA Panel v1.1
    RNA Library Prep AmpliSeq for Illumina Focus Panel v1.1
  • Standard Workflow AmpliSeq for Illumina Focus Panel v1.1

  • Standard Workflow AmpliSeq for Illumina Immune Repertoire Panel v1.1
    Standard Workflow AmpliSeq for Illumina Immune Response Panel v1.1
    RNA Library Prep AmpliSeq for Illumina Myeloid Panel v1.1
  • Standard Workflow AmpliSeq for Illumina Myeloid Panel v1.1

  • Standard Workflow AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.1

    Release Notes

    Last Updated: November 2024

    Release Date: September 2023

    Document Version: 2

    These release notes describe the key changes to Illumina Preset Protocols (IPP) v2.6.

    hashtag
    Compatibility

    Refer to under Instruments & Integrations.

    hashtag
    New Features

    • Updated the non-IGA Python2 scripts to Python3. Symbolic links for Python 2 and 3 are removed from Clarity LIMS v6.2. All Python scripts are run under Python 3. If you have customized Python2 or 3 scripts in your existing workflows, then you must run them using the appropriate versions of Python (ie, Python2 or Python3).

    • Updated third-party dependency libraries.

    • Enabled the NovaSeq 6000 v3.8 workflow with CLPA.

    hashtag
    Defects Fixed

    • Fixed the MiSeq sample sheet so that it now displays the pool name when the pool contains only one sample instead of the sample name. It also displays the well and plate information for submitted samples instead of for libraries.

    • Added missing PCR Product LIMSID custom field for CDC COVID-19 RT-PCR v1.0 workflow.

    • Fixed the bclfastq_reverse complement template so that it now uses the correct column name for the HIDE command.

    hashtag
    Known Issues

    None

    hashtag
    Revision History

    Renamed the following protocol and workflow in AmpliSeq-Illumina-Immune-Repertoire-Panel:
    • Standard Workflow (AmpliSeq for Illumina Response Panel v1.0) protocol to Standard Workflow (AmpliSeq for Illumina Repertoire Panel v1.0)

    • Standard Workflow AmpliSeq for Illumina Immune Response Panel v1.0 workflow to Standard Workflow AmpliSeq for Illumina Immune Repertoire Panel v1.0

  • Fixed workflow and step versions that were out of sync in the Nextera Rapid Capture Custom Enrichment workflow.

  • Fixed the Validate Flowcell Barcode automation (in the Load to Flowcell step of the NovaSeq Xp Protocol in the COIVDSeq workflow) so that it now accepts only uppercase alphanumeric characters in the first five positions of the barcode.

  • Fixed the non-IGA workflows so that they now show the Hide File Column Display and Manual File Attachment Method options under the File Column Options. The workflows previously showed the Hide File Column Display and Auto File Attachment Method options.

  • Version

    Changes

    2

    • Updated Compatibility section to reference Compatibility matrix table.

    1

    • Initial release.

    Compatibility

    Installation and User Configuration

    The Illumina Preset Protocols (IPP) v2.6 support the integration of Clarity LIMS with established lab protocols.

    The integration provides preconfigured workflows that map to lab protocols and steps, and support Illumina library prep kits, reagent kits, assays, and instruments.

    This guide provides instructions and describes the components installed in the default configuration of IPP.

    hashtag
    Installation Components

    IPP Integration v2.6 is distributed as the BaseSpaceLIMS-Illumina-Preset-Protocols RPM package. The RPM package installs the following components:

    • The illumina-preset-protocols-installer.sh script for configuration slices.

    • Templates for the following uses:

      • Sample sheet generation

    chevron-rightSample Sheet Generation Templateshashtag
    • BCL2FASTQ_Reverse_Complement_Samplesheet.csv

    • BCL2FASTQ_Samplesheet.csv

    chevron-rightSample Placement Pattern Templateshashtag
    • Hybrid Pattern_96 well plate_8x1 HD BeadChip.tsv

    • Hybrid Pattern_96 well plate_8x1 LCG BeadChip.tsv

    chevron-rightCovid-Related Templateshashtag
    • 7900sds_container_setup_template.txt

    • covid_report_results.csv

    chevron-rightIllumina Genomics Architecture (IGA) Templateshashtag
    • BatchingInputFile_template.csv

    • CaptureWashInputFile_template.csv

    chevron-rightPython Scripts for Automation Supporthashtag
    • autoPlaceCovid7500.py

    • clarityapiutil.py

    chevron-rightPython Scripts for IGA Automation Supporthashtag
    • glsapiutil:

      • glsapiutil.py

    chevron-rightClarity LIMS Product Analytics Automation Scripthashtag
    • unified-product-analytics-automation.jar

    chevron-rightConfiguration Sliceshashtag

    The following configuration slices are included in IPP Integration v2.6:

    • Illumina_Instruments, including:

    chevron-rightInstruments and Workflowshashtag

    IPP Integration v2.6 contains workflows that are used to integrate the following instruments:

    • iScan

    • iSeq

    hashtag
    Protocols and Configuration Slices

    IPP Integration v2.6 provides protocols that contain configuration slices. These configuration slices are used to install other workflows and protocols.

    hashtag
    QC_Protocols

    QC_Protocols configuration component contains the qc-protocols base slice. This configuration does not contain any workflows, but it does provide the following protocols that are used by other workflows:

    • DNA Initial QC

    • Library Validation QC

    • RNA Initial QC

    The following table shows the components that are installed with the QC_Protocols configuration.

    Components Installed with QC_Protocols

    hashtag
    AmpliSeq_for_Illumina_Protocols

    The following table shows the AmpliSeq_for_Illumina_Protocols configuration slices and the workflows that are installed with IPP Integration v2.6.

    AmpliSeq_for_Illumina_Protocols Configuration Slices and Workflows

    hashtag
    Additional Configuration Slices

    The following table shows additional configuration slices and workflows that are installed with IPP Integration v2.6.

    Additional Configuration Slices and Workflows

    hashtag
    IPP Integration v2.6 Package Installation

    The BaseSpaceLIMS-Ilumina-Preset-Protocols RPM package provides instructions for locating and running the /opt/gls/clarity/config/illumina-preset-protocols-installer.sh bash script that launches the IPP configuration installer.

    The RPM package automatically installs template files that are used with Template File Generator (TFG) and Sample Placement Helper. These template files are accessible after the applicable configuration is installed. The files are installed at the following locations:

    • /opt/gls/clarity/extensions/conf/driverfiletemplates

    • /opt/gls/clarity/extensions/conf/infinium/placementpatterns

    • /opt/gls/clarity/extensions/conf/covid

    The RPM package automatically installs the CLPA automation that is used for the CLPA integration. This automation is installed at the following location:

    If this is a new Clarity LIMS installation, you must install the QC_Protocols before the preconfigured workflows. The base configuration is included in the standard installation process.

    After you have selected a workflow, the installer validates the import of that workflow and provides Warning/Error details in STDOUT. This process allows you to proceed with the import or cancel it.

    chevron-rightPrerequisiteshashtag

    Before installing the RPM package, make sure that the following software is installed:

    • Clarity LIMS v6.2 or later

    • NGS-Package v5.23.0 or later

    chevron-rightRPM Installationhashtag
    1. On the server used for the IPP RPM installation, log in as the root user.

    2. Use the yum command to install the RPM. The command line is as follows.

      The --enablerepo piece of the command line must be included to enable the repo. The Illumina Support team provides the repo file and the appropriate name to use.

    hashtag
    Installer Parameters and Operations

    The IPP Integration v2.6 installer uses parameters and operations to assist with the configuration installation.

    You must run the installer as the glsjboss user. The following table describes the parameters that are available for use with the installer.

    IPP Installer Parameters

    hashtag
    List Operation

    Run the installer with the list operation for a list of all configuration installation options in a two-column format. The first column shows the IPP workflow identifier (or Id) that the installer uses when running the install operation. The second column shows the name of the configuration associated with the identifier.

    As the glsjboss user, run the following command to view the list of IPP workflows:

    hashtag
    Install Operation

    Use the install operation to install the configuration slices. Specify both the name of the parent item and the name of the configuration slice, separated by a period, as follows:

    For example, to install the qc-protocols slice, run the following command:

    hashtag
    All Operation

    The all operation is a special option that is available at the top level and parent item level.

    • At the top level, use the operation to install every configuration package from IPP Integration v2.6. To use the all operation at this level, run the following command:

    • At the parent item level, use the operation to install the workflows associated with a specific parent item. For example, run the following command to install the workflows associated with the AmpliSeq_for_Illumina_Protocols parent item:

    circle-info

    There is no all option available for QC_Protocols and Targeted_Amplicon_Protocols as they each contain only one configuration slice. Including all in the install command for these items generates an error.

    hashtag
    Headless Mode

    Headless mode allows the install operation to complete without prompting for input. Use this mode if you want to automate the installation. When running the installation in headless mode, the process still runs through the validation phase before importing the configuration. However, if a conflict is found, the configuration causing the conflict is skipped automatically.

    hashtag
    Installation Validation

    The IPP installer validates the configuration import. If conflicts are found during the validation, a warning message displays. This message provides the following options:

    • f/Import anyway

    • s/Skip this workflow

    • a/Abort

    The f/Import anyway option runs the import command of the config slicer tool. It also allows the tool to handle conflicts. This option does not run the config slicer tool in importAndOverwrite mode.

    The s/Skip this workflow option does not import workflows where conflicts were found, but continues to import the other selected slices.

    The a/Abort option aborts all import operations. The conflicts found are captured in the log files and can be reviewed.

    hashtag
    Track and Log the Installation

    The IPP installer tracks the installation process in the installhistory table and generates log files that can be reviewed after the installation is complete.

    chevron-rightViewing the installhistory Tablehashtag

    After installation is complete, a record is stored in the installhistory table in the database.

    To view the installation record, use the following command:

    If a configuration slice is installed multiple times, there are multiple entries in the record. This scenario can happen during an upgrade or if there are attempts to resolve conflicts during installation. The log shows the following information for each slice:

    chevron-rightViewing the Log Fileshashtag

    After the configuration package is installed, the following log files are available:

    • ipp-installer.log

    • configslicer.log

    Sample placement pattern
  • Covid testing setup and reporting

  • Illumina Genomics Architecture (IGA)

  • Automation scripts, including scripts to support IGA and Clarity LIMS Product Analytics (CLPA) automation.

  • Configuration slices.

  • Workflows for applicable instrument integrations.

  • genomeStudio_Genotyping_SampleSheet_driver_file.csv
  • genomeStudio_Methylation_SampleSheet_driver_file.csv

  • iSeq_Samplesheet.csv

  • iSeqManual_Samplesheet.csv

  • miniSeq_Samplesheet.csv

  • MiSeqSamplesheetv3.csv

  • NextSeq1K2K_Pool1.csv

  • NextSeq1K2K_Pool2.csv

  • NextSeq1K2K_Pool3.csv

  • NovaSeq_BCL2FASTQ_Samplesheet.csv

  • NovaSeq_BCL2FASTQ_Samplesheet_v2.csv

  • NovaSeq_BCL2FASTQ_Reverse_Complement_Samplesheet.csv

  • NovaSeq_Standard_Bulk_Pool1.csv

  • NovaSeq_Standard_Bulk_Pool2.csv

  • NovaSeq_Standard_Bulk_Pool3.csv

  • NovaSeq_Xp_Bulk_Pool.csv

  • NovaSeq_Xp_Bulk_Pool2.csv

  • NovaSeq_Xp_Working_Pool.csv

  • NovaSeq_Xp_Working_Pool2.csv

  • NovaSeqDx_BCL2FASTQ_Samplesheet.csv

  • NovaSeqXSeries_Bulk_Pool1.csv

  • NovaSeqXSeries_Bulk_Pool2.csv

  • NovaSeqXSeries_Dilute_Denature_Calculate_Volumes.csv

  • Hybrid Pattern_96 well plate_12x1 HD BeadChip.tsv
  • Hybrid Pattern_96 well plate_24x1 HD BeadChip.tsv

  • Hybrid Pattern_96 well plate_24x1 HTS BeadChip.tsv

  • Hybrid Pattern_96 well plate_24x1 HTS BeadChip Multichannel.tsv

  • Hybrid Pattern_96 well plate_24x4 XT BeadChip.tsv

  • ExtractionInputFile_template.csv
  • LibInputFile_NFE_template_withoffsets.csv

  • LibInputFile_NFPF_template_withoffsets.csv

  • LoadToFlowcell_NovaSeqXp_Incomplete_template.csv

  • LoadToFlowcell_NovaSeqXp_ManifestForConsolidation_template.csv

  • LoadToFlowcell_NovaSeqXp_template.csv

  • LoadToLibTubeFile_NovaSeqStd_template.csv

  • MakeBPFile_NovaSeq_template.csv

  • PlatingInputFile_template.csv

  • parseCovidSeqRunReport.py
  • verifyBeadChipIDs.py

  • glsapiutil3.py

  • hamilton_fast_prep:

    • 01_A_CFP_Batching_defaultContainerCheck.py

    • 01_CFP_Batching_confirmPlateID.py

    • 01_CFP_Batching_confirmPlateIDAndStoreInstrumentID.py

    • 02_ReagentParsing.py

    • 03_checkHamiltonFileNameBarcode.py

    • 04_A_checkIndexPlateBarcodeWithCategory.py

    • 04_B_autoAssignIndexesFromIndexPlanning.py

    • 05_reusedIndexPlateWarning.py

    • countSamples.py

    • countSamplesInPools.py

    • validate_sample_placement.py

  • iga_helpers:

    • clarityUIFileHelper.py

    • pop_up_msg.py

    • printCurrentWorkflow.py

  • iga_novaseq:

    • 01_NovaSeqStd_confirmPlateIDAndStoreInstrumentID_OptionalFile.py

    • 02_NovaSeqStd_confirmPlateIDAndStoreInstrumentID_OptionalFile_DiluteDenature.py

    • 03_NovaSeqXp_confirmBPPPlateAndStoreInstrumentID.py

    • 03_NovaSeqXp_consolidateBulkPoolFiles.py

    • 04_NovaSeqXp_completeAndConsolidateWPPZipFile.py

    • NovaSeq_automated_warning.py

    • NovaSeq_pooling_warning.py

    • validate_floorcell_container.py

    • validate_flowcell_pools.py

    • validate_multiple_destination_plates.py

  • illumina-cobalt-samplesheet-converter:

    • ss_converter

    • converter.py

    • errors.py

    • v1_builder_plugins.py

    • v1_v2_handler.py

    • v2_converter_plugins.py

  • index_correct

    • apply_correction_factors.py

  • make_bpp:

    • apply_multiple_bulk_pools.py

    • calculate_sample_volume.py

  • utils:

    • common.py

    • igaapiutil.py

  • iScan-v1.0
  • iSeq-100-v1.0

  • Library-Prep-Validation-v2.3

  • miniSeq-v1.0

  • miseq-v3.2

  • NextSeq1k2k-v2.3

  • nextseq550-v1.1

  • novaseq-v3.8

  • novaseqdx-v1.2

  • NovaSeqXSeries-v1.0

  • QC_Protocols

    • qc-protocols

  • Ampliseq_for_Illumina_Protocols, including:

    • AmpliSeq-Illumina-BRCA-Panel-v1.1

    • AmpliSeq-Illumina-Cancer-HotSpot-Panel-V2-v1.1

    • AmpliSeq-Illumina-Childhood-Cancer-Panel-v1.1

    • AmpliSeq-Illumina-Comprehensive-Cancer-Panel-v1.1

    • AmpliSeq-Illumina-Comprehensive-Panel-v3-v1.1

    • AmpliSeq-Illumina-Custom-DNA-Panel-v1.1

    • AmpliSeq-Illumina-Focus-Panel-v1.1

    • AmpliSeq-Illumina-Immune-Repertoire-Panel-v1.1

    • AmpliSeq-Illumina-Immune-Response-Panel-v1.1

    • AmpliSeq-Illumina-Myeloid-Panel-v1.1

    • AmpliSeq-Illumina-TCR-beta-SR-Panel-v1.1

    • AmpliSeq-Illumina-Transcriptome-Human-Gene-Expression-Panel-v1.1

  • Covid, including:

    • CDC-COVID-19-RT-PCR-v1.1

    • Illumina-COVIDSeq-Workflow-v1.5

    • Respiratory-Virus-Panel-v1.0

  • DNA_Protocols, including:

    • ILASS-TruSight-Whole-Genome-Assay-v1.2

    • Illumina-DNA-PCR-Free-Library-Prep-Manual-v1.0

    • Illumina-DNA-Prep-M-Tagmentation-v1.0

    • Nextera-Mate-Pair-v1.0

    • Nextera-XT-v2.0

    • TruSeq-DNA-PCR-Free-v2.0

    • TruSeq-Nano-DNA-v1.0

  • IGA, including:

    • IGA_Library_Prep_Automated_v2.1

    • IGA_NovaSeq_Sequencing_v2.2

  • Infinium_Array, including:

    • Genome-Studio-v1.0

    • ILASS-Infinium-Genotyping-Assay-v1.0

    • Infinium-HD-Methylation-Assay-Manual-v1.2

    • Infinium-HTS-Assay-Manual-v1.2

    • Infinium-LCG-Assay-Manual-v1.2

    • Infinium-XT-Assay-Manual-v1.2

  • Methylation_Protocols, including:

    • TruSeq-ChIP-Seq-v1.0

    • TruSeq-Methyl-Capture-EPIC-v2.0

  • RNA_Protocols, including:

    • Illumina-Stranded-mRNA-Prep-Ligation-v1.0

    • Illumina-Stranded-Total-RNA-Prep-Ligation-with-Ribo-Zero-Plus-v1.0

    • TruSeq-Small-RNA-v1.0

    • TruSeq-Stranded-mRNA-v2.1

  • Targeted_Amplicon_Protocols

    • TruSeq-Custom-Amplicon-v1.0

  • Targeted_Enrichment_Protocols, including:

    • Illumina-DNA-Prep-with-Enrichment-S-Tagmentation-v1.1

    • Illumina-RNA-Prep-with-Enrichment-L-Tagmentation-v1.0

    • Nextera-Rapid-Capture-Custom-Enrichment-v2.0

    • TruSeq-DNA-Exome-v2.0

    • TruSeq-RNA-Exome-v1.0

  • TruSight_Oncology_Protocols, including:

    • TruSight-Oncology-500-ctDNA-v1.1

    • TruSight-Oncology-500-HT-v1.1

    • TruSight-Oncology-500-v1.1

    • TruSight-Tumor-170-v2.0

  • MiSeq

  • MiniSeq

  • NextSeq 500/550

  • NextSeq 1000/2000

  • NovaSeq 6000

  • NovaSeq 6000Dx

  • NovaSeq X Series

  • The following workflows are included in the integration:

    • iScan v1.0

    • iSeq 100 v1.0

    • Library Prep Validation v2.3.1 (includes the applicable library prep workflows for each integration)

    • MiniSeq v1.0

    • MiSeq Sequencing v3.2

    • NextSeq 500/550 Sequencing v1.1

    • NovaSeq 6000 v3.8

    • NextSeq 1000/2000 Sequencing v2.3

    • NovaSeqDx v1.2

    • NovaSeq X Series Sequencing v1.0

    These workflows require ClarityLIMS-NGS-Package v5.23.0 or later so that the Template File Generator tool can be used.

    • Application

    • Pooling

    • Progress

    Container custom fields

    • Container Name

    • LIMS ID (Container)

    • Well

    Project custom fields

    • Project Name

    Derived sample custom fields

    • A260/280 ratio

    • Conc. Units

    • Concentration

    Measurement custom fields

    • 28s/18s ratio

    • A260

    • A260/230 ratio

    • DNA Library Prep AmpliSeq for Illumina Focus Panel v1.1

    • Equalizer AmpliSeq for Illumina Focus Panel v1.1

    • RNA Library Prep AmpliSeq for Focus Panel v1.1

    AmpliSeq-Illumina-Immune-Repertoire-Panel-v1.1

    • Equalizer AmpliSeq for Illumina Immune Repertoire Panel v1.1

    • RNA Library Prep AmpliSeq for Illumina Immune Repertoire Panel v1.1

    • Standard Workflow AmpliSeq for Illumina Immune Response Panel v1.1

    AmpliSeq-Illumina-Immune-Response-Panel-v1.1

    • Equalizer Workflow AmpliSeq for Illumina Immune Response Panel v1.1

    • RNA Library Prep AmpliSeq for Illumina Immune Response Panel v1.1

    • Standard Workflow AmpliSeq for Illumina Immune Response Panel v1.1

    AmpliSeq-Illumina-Myeloid-Panel-v1.1

    • DNA Library Prep AmpliSeq for Illumina Myeloid Panel v1.1

    • Equalizer Workflow AmpliSeq for Illumina Myeloid Panel v1.1

    • RNA Library Prep AmpliSeq for Illumina Myeloid Panel v1.1

    AmpliSeq-Illumina-TCR-beta-SR-Panel-v1.1

    • DNA Library Prep AmpliSeq for Illumina TCR beta-SR Panel v1.1

    • RNA Library Prep AmpliSeq for Illumina TCR beta-SR Panel v1.1

    AmpliSeq-Illumina-Transcriptome-Human-Gene-Expression-Panel-v1.1

    • Equalizer Workflow AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.1

    • RNA Library Prep AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.1

    • Standard Workflow AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.1

    • TruSeq Custom Amplicon v1.0.7

    Targeted_Enrichment_Protocols

    • Illumina DNA Prep with Enrichment (S) Tagmentation v1.1

    • Illumina RNA Prep with Enrichment (L) Tagmentation v1.0

    • Nextera Rapid Capture Custom Enrichment v2.0.8

    TruSight_Oncology_Protocols

    • TruSight Oncology 500 ctDNA v1.1

    • TruSight Oncology 500 HT v1.1

    • TruSight Oncology 500 v1.1

    SecretUtil v1.2. For more information, refer to Guide to Secret Management in the Clarity LIMS (Clarity & LabLink Reference Guide) documentation.

  • When you are prompted to proceed with the RPM package installation, enter y to confirm.

  • For information on running the installer and supported commands, parameters, and options, refer to Installer Parameters and Operations.

    Product — The name of the slice (e.g., IPP - LIMS 5 - TruSight_Oncology_Protocols.TruSight-Oncology-500-HT-v1.0).
  • Version — The version of the configuration slice that was installed (e.g., 2.0.0.25).

  • InstallDate — The time stamp for when the slice was installed. The date displays first (in YYYY-MM-DD format), followed by the time (in HH:MM:SS format)

  • omxprops.log

    The ipp-installer.log file captures the output of the IPP installer tool. The name and location of this file can be changed with the command line options described previously. The default location is as follows:

    The configslicer.log and omxprops.log files are raw outputs from their respective tools. These files contain more detail than the ipp-installer.log file. For example, if a conflict is identified in the ipp-installer.log file, the configslicer.log file shows the specific entry causing the conflict. Some workflow selections, such as the MiSeq and NextSeq integration workflows, import database properties in addition to a configuration slice.

    By default, only the ipp-installer.log file is generated in the following directory:

    When the -l operation is specified during installation, all three log files are available in the current working directory.

    Component

    Items Installed

    Protocols

    • DNA Initial QC 5.1.2

    • Library Validation QC 5.1.2

    • RNA Initial QC 5.1.2

    Master Steps

    • Add Multiple Reagents

    • Adenylate ends & Ligate Adapters (TruSeq DNA) 5.1

    • Pool Samples

    • Aggregate QC (DNA) 5.1.2

    • Aggregate QC (Library Validation) 5.1.2

    • Aggregate QC (RNA) 5.1.2

    • Bioanalyzer QC (DNA) 5.1.2

    • Bioanalyzer QC (RNA) 5.1.2

    • CaliperGX QC 5.1.2

    • NanoDrop QC (DNA) 5.1.2

    • NanoDrop QC (RNA) 5.1.2

    • PicoGreen QC (DNA) 5.1.2

    • PicoGreen QC (RNA) 5.1.2

    • Qubit QC (DNA) 5.1.2

    • Qubit QC (RNA) 5.1.2

    • Tapestation QC (DNA) 5.1.2

    • Tapestation QC (RNA) 5.1.2

    • qPCR QC 5.1.2

    Container types

    • 384 well plate

    • 96 well plate

    • BioAnalyzer DNA 1000 Chip

    • BioAnalyzer DNA High Sensitivity Chip

    • BioAnalyzer RNA Nano Chip

    • BioAnalyzer RNA Pico Chip

    • Tube

    Label groups/reagent categories

    • TruSeq Custom Amplicon Adapters (A7-A5)

    • TruSeq DNA LT Adapters (AD series)

    • TruSeq Stranded mRNA LT Adapters (AR series)

    • TruSeq HT Adapters (D7-D5)

    • Nextera Enrichment & Rapid Capture Adapters (N7-E5)

    • Nextera DNA Adapters (N7-N5, S7-S5)

    • NoIndex

    • TruSeq Small RNA Adapters (RPI series)

    Reagent kits

    • TruSeq DNA PCR-Free Kit - Adapter Plate Box

    • TruSeq DNA PCR-Free Kit - Core Reagents Box

    • TruSeq DNA PCR-Free Kit - SP Beads Box

    Controls

    • Endogenous Positive Control

    • Exogenous Positive Control

    • No Amplification Control

    • No Reverse Transcriptase Control

    • No Template Control

    • PhiX v3

    Configuration Slice

    Workflows

    AmpliSeq-Illumina-BRCA-Panel-v1.1

    • Equalizer Workflow AmpliSeq for Illumina BRCA Panel v1.1

    • Library Prep AmpliSeq for Illumina BRCA Panel v1.1

    • Standard Workflow AmpliSeq for Illumina BRCA Panel v1.1

    AmpliSeq-Illumina-Cancer-HotSpot-Panel-V2-v1.1

    • Library Prep AmpliSeq for Illumina Cancer HotSpot Panel V2 v1.1

    • Standard Workflow AmpliSeq for Illumina Cancer HotSpot Panel V2 v1.1

    AmpliSeq-Illumina-Childhood-Cancer-Panel-v1.1

    • DNA Library Prep AmpliSeq for Illumina Childhood Cancer Panel v1.1

    • Equalizer Workflow AmpliSeq for Illumina Childhood Cancer Panel v1.1

    • RNA Library Prep AmpliSeq for Illumina Childhood Cancer Panel v1.1

    • Standard Workflow AmpliSeq for Illumina Childhood Cancer Panel v1.1

    AmpliSeq-Illumina-Comprehensive-Cancer-Panel-v1.1

    • Equalizer Workflow AmpliSeq for Illumina Comprehensive Cancer Panel v1.1

    • Library Prep AmpliSeq for Illumina Comprehensive Cancer Panel v1.1

    • Standard Workflow AmpliSeq for Illumina Comprehensive Cancer Panel v1.1

    AmpliSeq-Illumina-Comprehensive-Panel-v3-v1.1

    • DNA Library Prep AmpliSeq for Illumina Comprehensive Panel v3 v1.1

    • Equalizer Workflow AmpliSeq for Illumina Comprehensive Panel v3 v1.1

    • RNA Library Prep AmpliSeq for Illumina Comprehensive Panel v3 v1.1

    • Standard Workflow AmpliSeq for Illumina Comprehensive Panel v3 v1.1

    AmpliSeq-Illumina-Custom-DNA-Panel-v1.1

    • Equalizer Workflow AmpliSeq for Illumina Custom DNA Panel v1.1

    • Library Prep AmpliSeq for Illumina Custom DNA Panel v1.1

    • Standard Workflow AmpliSeq for Illumina Custom DNA Panel v1.1

    Configuration Slice

    Workflows

    Covid

    • CDC COVID-19 RT PCR v1.1

      • Qiagen EZ1 Advanced XL CDC COVID-19 RT-PCR v1.1

      • Qiagen QIAamp DSP Viral RNA Mini Kit CDC COVID-19 RT-PCR v1.1

      • Roche MagNA Pure 96 CDC COVID-19 RT-PCR v1.1

      • Roche MagNA Pure Compact CDC COVID-19 RT-PCR v1.1

      • Roche MagNA Pure LC CDC COVID-19 RT-PCR v1.1

      • Sort Specimens to Extraction CDC COVID-19 RT-PCR v1.1

      • bioMerieux EMAG Instrument CDC COVID-19 RT-PCR v1.1

      • bioMerieux NucliSENS easyMAG Instrument CDC COVID-19 RT-PCR v1.1

    • Illumina COVIDSeq Workflow v1.5

    • Respiratory Virus Panel v1.0

    DNA_Protocols

    • ILASS TruSight Whole Genome Assay v1.2

    • Illumina DNA PCR-Free Library Prep Manual v1.0.2

    • Illumina DNA Prep (M) Tagmentation v1.0.6

    • Nextera Mate Pair v1.0.7

    • Nextera XT DNA v2.0.7

    • TruSeq DNA PCR-Free v2.0.7

    • TruSeq Nano DNA v1.0.7

    IGA

    • Illumina Genomics Architecture - Library Prep Automated v2.1

      • Sample Selection (IGA v2.1)

      • Sample Plating (IGA v2.1)

      • Blood Extraction (IGA v2.1)

      • Saliva Extraction (IGA v2.1)

      • Illumina DNA PCR-Free (IGA v2.1)

      • Illumina DNA with Enrichment (IGA v2.1)

      • Sequencing Platform Selection (IGA v2.1)

    • Illumina Genomics Architecture - NovaSeq Sequencing v2.1

      • Run Format (IGA v2.1)

      • NovaSeq Standard (IGA v2.1)

    ℹ IGA workflows require additional installation steps. For assistance, contact Illumina Technical Support. Note also that Illumina Genomics Architecture - NovaSeq Sequencing v2.1 workflow is not the same workflow as NovaSeq 6000 v3.8.

    Infinium_Array

    • GenomeStudio v1.0

    • ILASS Infinium Genotyping Assay v1.0

    • ILASS Infinium Genotyping with PGx v1.0

    • Infinium HD Methylation Assay Manual v1.2

    • Infinium HTS Assay Manual v1.2

    • Infinium LCG Assay Manual v1.2

    • Infinium XT Assay Manual v1.2

    Methylation_Protocols

    • TruSeq ChIP-Seq v1.0.7

    • TruSeq Methyl Capture EPIC v2.0.8

    RNA_Protocols

    • Illumina Stranded mRNA Prep Ligation v1.0

    • Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus v1.0

    • TruSeq Small RNA v1.0.7

    • TruSeq Stranded mRNA v2.1.7

    Parameter

    Description

    Example Command

    --operation, -o

    Specifies the run mode for the installer. Supported modes are as follows:

    • help

    • list

    • install

    --headless, -h

    Run the installer in headless mode. Used for the install operation only.

    --log, -l

    Sets the log file name and destination. The default value is ipp-installer.log.

    Sample custom fields

    AmpliSeq-Illumina-Focus-Panel-v1.1

    Targeted_Amplicon_Protocols

    /opt/gls/clarity/extensions/unified-product-analytics/automation
    bash /opt/gls/clarity/config/illumina-preset-protocols-installer.sh -o list
    bash /opt/gls/clarity/config/illumina-preset-protocols-installer.sh --headless -o install QC_Protocols.qc-protocols
    bash /opt/gls/clarity/config/illumina-preset-protocols-installer.sh -l ipp-installer.log
    /opt/gls/clarity/config/illumina-preset-protocols-installer.sh -o list
    /opt/gls/clarity/config/illumina-preset-protocols-installer.sh -o install Parent_Item_name.slice_name
    /opt/gls/clarity/config/illumina-preset-protocols-installer.sh -o install QC_Protocols.qc-protocols
    bash /opt/gls/clarity/config/illumina-preset-protocols-installer.sh -o install all
    bash /opt/gls/clarity/config/illumina-preset-protocols-installer.sh -o install AmpliSeq_for_Illumina_Protocols.all
    java -jar /opt/gls/clarity/tools/propertytool/omxprops-ConfigTool.jar getInstallHistory
    yum install BaseSpaceLIMS-Illumina-Preset-Protocols --enablerepo=<< repo name info from support >>
    /opt/gls/clarity/logs/illumina-preset-protocols/{IPP version}/{Time-based Digits}/
    /opt/gls/clarity/logs/illumina-preset-protocols/{IPP version}/{Time-based Digits}/
    NovaSeq Xp (IGA v2.1)
  • AUTOMATED - NovaSeq Run (IGA v2.1)

  • Reference Genome
  • Sample Buffer

  • Sample Conc.

  • Units

  • Volume (ul)

  • Read Length

  • Sample Type

  • Sequencing Coverage

  • Sequencing Method

  • Sample Name
  • Waiting

  • Workflow

  • A260/280 ratio
  • BA Sample Name

  • Conc. Units

  • Concentration

  • MW Units

  • Molarity Units

  • Number of Peaks found

  • Number of Regions found

  • Peak 1% Integrated Area

  • Peak 1 Conc.

  • Peak 1 MW

  • Peak 1 Molarity

  • Peak 1 Size - bp

  • Peak 2% Integrated Area

  • Peak 2 Conc.

  • Peak 2 MW

  • Peak 2 Molarity

  • Peak 2 Size - bp

  • Peak 3% Integrated Area

  • Peak 3 Conc.

  • Peak 3 MW

  • Peak 3 Molarity

  • Peak 3 Size - bp

  • Peak 4% Integrated Area

  • Peak 4 Conc.

  • Peak 4 MW

  • Peak 4 Molarity

  • Peak 4 Size - bp

  • Peak 5% Integrated Area

  • Peak 5 Conc.

  • Peak 5 MW

  • Peak 5 Molarity

  • Peak 5 Size - bp

  • RIN

  • RNA Area

  • Region 1% of Total

  • Region 1 Average Size - bp

  • Region 1 Conc.

  • Region 1 Molarity

  • Region 2% of Total

  • Region 2 Average Size - bp

  • Region 2 Conc.

  • Region 2 Molarity

  • Region 3% of Total

  • Region 3 Average Size - bp

  • Region 3 Conc.

  • Region 3 Molarity

  • Region 4% of Total

  • Region 4 Average Size - bp

  • Region 4 Conc.

  • Region 4 Molarity

  • Region 5% of Total

  • Region 5 Average Size - bp

  • Region 5 Conc.

  • Region 5 Molarity

  • Sample Comment

  • Size (bp)

  • Standard Workflow AmpliSeq for Illumina Focus Panel v1.1
    Standard Workflow AmpliSeq for Illumina Myeloid Panel v1.1
    TruSeq DNA Exome v2.0.7
  • TruSeq RNA

    • TruSeq RNA Access v2.0.7

    • TruSeq RNA Exome v1.0.5

  • TruSight Tumor 170 v2.0.7