iLASS Infinium Genotyping Assay v1.1
Protocol 1: Target Prep (ILASS Infinium Genotyping Assay v1.1)
Protocol Type = Sample Prep
Next Steps Configuration
Step 1: Make WGA (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Make WGA (ILASS Infinium Genotyping Assay v1.1)
Derived Sample Generation = Fixed, 1
Placement = Enabled
Sample Grouping = Group by Containers
Placement Pattern = Same Shape
Step Data (Master Step Fields)
Step 2: Amplify WGA (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Amplify WGA (ILASS Infinium Genotyping Assay v1.1)
Set Next Step - Advance v1.0
Trigger Location = Record Details
Trigger Style = Manual button
Step Data (Master Step Fields)
Step 3: Fragment DNA (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Fragment DNA (ILASS Infinium Genotyping Assay v1.1)
Step Data (Master Step Fields)
Step 4: Precipitate DNA (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Precipitate DNA (ILASS Infinium Genotyping Assay v1.1)
Step Data (Master Step Fields)
Step 5: Resuspend DNA (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Resuspend DNA (ILASS Infinium Genotyping Assay v1.1)
Step Data (Master Step Fields)
Protocol 2: BeadChip Processing (ILASS Infinium Genotyping Assay v1.1)
Protocol Type = Sample Prep
Next Steps Configuration
Step 1: Prepare Hyb Chamber (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Prepare Hyb Chamber (ILASS Infinium Genotyping Assay v1.1)
Set Next Step - Advance v1.0
Trigger Location = Record Details
Trigger Style = Manual button
Step Data (Master Step Fields)
Step 2: Hybridize DNA to the BeadChip (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Hybridize DNA to the BeadChip (ILASS Infinium Genotyping Assay v1.1)
Derived Sample Generation = Fixed, 1
Placement = Enabled
Sample Grouping = Group by Containers
Step Data (Master Step Fields)
Step 3: Wash BeadChips (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Wash BeadChips (ILASS Infinium Genotyping Assay v1.1)
Set Next Step - Advance v1.0
Trigger Location = Record Details
Trigger Style = Manual button
Step Data (Master Step Fields)
Step 4: Extend and Stain BeadChips (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Extend and Stain BeadChips (ILASS Infinium Genotyping Assay v1.1)
Step Data (Master Step Fields)
Step 5: Wash and Coat BeadChips (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Wash and Coat BeadChips (ILASS Infinium Genotyping Assay v1.1)
Set Next Step - Advance v1.0
Trigger Location = Record Details
Trigger Style = Manual button
Step Data (Master Step Fields)
Protocol 3: Infinium Array Imaging on iScan (ILASS Infinium Genotyping Assay v1.1)
Protocol Type = Other
Next Steps Configuration
Step 1: Image Infinium BeadChip on iScan (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Image Infinium BeadChip on iScan (ILASS Infinium Genotyping Assay v1.1)
Derived Sample Generation = Fixed, 1
Step Data (Master Step Fields)
Protocol 4: Infinium Analysis (ILASS Infinium Genotyping Assay v1.1)
Protocol Type = Sample Prep
Next Steps Configuration
Step 1: Invoke Infinium Analysis (ILASS Infinium Genotyping Assay v1.1)
Master Step Name = Invoke Infinium Analysis (ILASS Infinium Genotyping Assay v1.1)
Derived Sample Generation = Fixed, 1
Start Analysis v1.0
Trigger Location = Record Details
Trigger Style = Manual button
Step Data (Master Step Fields)