The following Types of Analysis are currently supported by DRAGEN Array:
DRAGEN Array – Genotyping
DRAGEN Array – PGx – CNV calling
DRAGEN Array – PGx – Star allele annotation
DRAGEN Array - Methylation QC
These products/beadchips have been verified to be compatible with the following analyses and versions of DRAGEN Array:
Product | DRAGEN Array Version(s) | Analysis | Genome(s) |
---|---|---|---|
Item | Description |
---|---|
Item | Description |
---|---|
Item | Description |
---|---|
Item | Description |
---|---|
BovineSNP50_v3_A
v1.0, v1.1
DRAGEN Array – Genotyping
UMD3
GDA-8v1-0_D
v1.0, v1.1
DRAGEN Array – Genotyping
GRCh37, GRCh38
GDA_PGx-8v1-0_20042614_E
v1.0, v1.1
DRAGEN Array – Genotyping
GRCh37, GRCh38
GDA_PGx-8v1-0_20042614_E
v1.0, v1.1
DRAGEN Array – PGx - CNV calling
GRCh37, GRCh38
GDA_PGx-8v1-0_20042614_E
v1.0
DRAGEN Array – PGx - Star allele annotate
GRCh38
GDA_PGx-8v1-0_20042614_G
v1.1
DRAGEN Array – Genotyping
GRCh38
GDA_PGx-8v1-0_20042614_G
v1.1
DRAGEN Array – PGx - CNV Calling
GRCh38
GDA_PGx-8v1-0_20042614_G
v1.1
DRAGEN Array – PGx - Star allele annotate
GRCh38
GSA-24v3-0_A
v1.0, v1.1
DRAGEN Array – Genotyping
GRCh37, GRCh38
GSA-PGx-48v4-0_20079540_E
v1.1
DRAGEN Array – Genotyping
GRCh38
GSA-PGx-48v4-0_20079540_E
v1.1
DRAGEN Array – PGx - CNV Calling
GRCh38
GSA-PGx-48v4-0_20079540_E
v1.1
DRAGEN Array – PGx - Star allele annotate
GRCh38
GCRA-PGx-24v1-0_20084467_C
v1.1
DRAGEN Array – Genotyping
GRCh38
GCRA-PGx-24v1-0_20084467_C
v1.1
DRAGEN Array – PGx - CNV Calling
GRCh38
GCRA-PGx-24v1-0_20084467_C
v1.1
DRAGEN Array – PGx - Star allele annotate
GRCh38
PRSbooster_20083382_A
v1.0, v1.1
DRAGEN Array – Genotyping
GRCh37
EPIC-8v1-0_B5
v1.0
DRAGEN Array – Methylation - QC
GRCh38
EPIC-8v2-0_A2
v1.0
DRAGEN Array – Methylation - QC
GRCh38
MSA-48v1-0_20102838_A1
v1.0
DRAGEN Array – Methylation - QC
GRCh38
Summary
Provides genotyping results for any human Infinium genotyping array.
Variant types detected
SNV
Indel
Sample minimum
1 sample
Arrays supported
Any human Infinium genotyping array including custom and semi-custom to create a SNV VCF output. Illumina provides Genome FASTA Files required to map to the reference genome for human, genome build 37 and 38. DRAGEN Array Cloud offers additional output formats including Locus Summary and Final Report which are applicable for Infinium arrays for human and non-human species.
Related Local Commands
Genotype Call
Genotype GTC-to-VCF
Related Cloud Specifics
Select Type of Analysis DRAGEN Array - Genotyping from the dropdown. Max 1152 samples are supported.
Inputs
• IDAT(s)
• Manifest Files [may be pre-setup on cloud]
• Cluster File [may be pre-setup on cloud]
• Genome FASTA Files [pre-setup on cloud]
• Sample Sheet [optional on cloud and local]
Outputs
Per sample:
• SNV VCF File [optional on cloud and local]
• TBI Index File [optional on cloud and local]
Per analysis batch:
• Final Report [cloud only]
• Locus Summary [cloud only]
Cost
Local: No cost download from Illumina Support Site.
Cloud: iCredits to analyze and store data as needed.
Summary
Provides CNV calling on 7 target PGx genes across 10 target regions, plus genotyping outputs.
Variant types detected
SNV
Indel
CNV
Sample minimum
Minimum of 24 samples with 22 passing QC defined as Log R Dev < 0.2. 96 samples are recommended for best results.
Arrays supported
Check Product & Analysis Compatibility here Product & Analysis Compatibility
See Pharmacogenomic Analysis for semi-custom arrays for further detail.
Related Local Commands
Genotype Call
Genotype GTC-to-VCF [optional]
Copy-number Call
Related Cloud Specifics
Select Type of Analysis DRAGEN Array - PGx – CNV calling from the dropdown. Max 384 samples are supported.
Inputs
• IDAT(s)
• Manifest Files [may be pre-setup on cloud]
• Cluster File [may be pre-setup on cloud]
• Genome FASTA Files [pre-setup on cloud]
• CN Model File [pre-setup on cloud]
• Sample Sheet [optional on cloud and local]
Outputs
Per sample:
• SNV VCF File [optional on local]
• TBI Index File [optional on local]
• BedGraph File [optional on local]
Per analysis batch:
Cost
Local: No cost download from Illumina Support Site.
Cloud: iCredits to analyze and store data as needed.
Summary
Provides PGx annotation on over 50 genes, plus PGx CNV and genotyping outputs
Variant types detected
SNV
Indel
CNV
Star allele diplotype
Sample minimum
Minimum of 24 samples with 22 passing QC defined as Log R Dev < 0.2. 96 samples are recommended for best results.
Arrays supported
Check Product & Analysis Compatibility here Product & Analysis Compatibility
See Pharmacogenomic Analysis for semi-custom arrays for further detail.
Related Local Commands
Genotype call
Genotype GTC-to-VCF [optional]
Copy-number call
Star-allele call
Star-allele annotate
Related Cloud Specifics
Select Type of Analysis DRAGEN Array - PGx – Star Allele Annotation from the dropdown. Max 384 samples are supported.
Inputs
• IDAT(s)
• Manifest Files [may be pre-setup on cloud]
• Cluster File [may be pre-setup on cloud]
• Genome FASTA Files [pre-setup on cloud]
• CN Model File [pre-setup on cloud]
• PGx Database File [pre-setup on cloud]
• Sample Sheet [optional on cloud and local]
Outputs
Per sample:
• SNV VCF File [optional on local]
• TBI Index File [optional on local]
• BedGraph File [optional on local]
Per analysis batch:
Cost
Local: Per sample analysis.
Cloud: Per sample analysis. iCredits to store data as needed.
Visit the Illumina Product Page to learn more.
Summary
Provides methylation QC for Infinium methylation arrays.
Variant types detected
N/A
Sample minimum
1 sample
Arrays supported
Recommended thresholds and all built-in control probes are available for Methylation Screening Array (MSA) and MethylationEPIC (v1 & v2) originating from iScan. In non-human and custom arrays, availability of built-in QC probes may vary, and failure thresholds must be defined by the user.
Related Local Commands
Not available on DRAGEN Array Local.
Related Cloud Specifics
Select Type of Analysis DRAGEN Array – Methylation – QC from the dropdown. Adjust customizable thresholds as desired. Further detail can be found in Additional information for DRAGEN Array Methylation QC. A maximum of 1152 samples are supported, with known limitations when sample sheet is used.
Inputs
• IDAT(s) [from iScan instrument] • Manifest Files [may be pre-setup on cloud] • IDAT Sample Sheet [optional on cloud]
Outputs
Cost
Cloud: iCredits to analyze and store data as needed.