# Other scRNA prep

A DRAGEN recipe, like this one, is a predefined set of analysis parameters and workflow settings tailored to a specific type of genomic analysis. For clarity, some default parameters are explicitly included and annotated with comments.

```
  
/opt/dragen/$VERSION/bin/dragen         #DRAGEN install path 
--ref-dir $REF_DIR                      #path to DRAGEN linear hashtable 
--output-directory $OUTPUT 
--intermediate-results-dir $PATH        #e.g. SSD /staging 
--output-file-prefix $PREFIX 
# Inputs 
--fastq-list $PATH                      #see 'Input Options' for FQ, BAM or CRAM 
--fastq-list-sample-id $STRING 
# Mapper 
--enable-rna true 
--annotation-file $GTF                  #GTF or GFF3 format 
--enable-map-align true                 #required for RNA/scRNA 
--enable-map-align-output true          #optionally save the output BAM 
--enable-sort true                      #default=true 
# Other Single Cell Prep 
--enable-single-cell-rna true 
--umi-source qname                      #default='qname' 
--scrna-barcode-position $BARCODE_POS   #see notes 
--scrna-umi-position $UMI_POS           #see notes 
--scrna-barcode-sequence-list $PATH 
--single-cell-threshold ratio           #['fixed', 'ratio', inflection'] 
--single-cell-threshold-filterby umi    #['umi', 'read'] 
```

## Notes and additional options

### Hashtable

For DRAGEN RNA/scRNA runs, it is recommended to use the linear hashtable.

See: [Product Files](https://support.illumina.com/sequencing/sequencing_software/dragen-bio-it-platform/product_files.html)

### Input options

DRAGEN input sources include: fastq list, fastq, bam, or cram. For BCL input, first create FASTQs using [BCL conversion](/dragen/dragen-v4.5/product-guides/dragen-v4.5/bcl-conversion.md).

FQ list Input

```
--fastq-list $PATH 
--fastq-list-sample-id $STRING 
```

FQ Input

```
--fastq-file1 $PATH 
--fastq-file2 $PATH 
--RGSM $STRING 
--RGID $STRING 
```

BAM Input

```
--bam-input $PATH 
```

CRAM Input

```
--cram-input $PATH 
```

### Mapping and Aligning

| Option                           | Description                                                    |
| -------------------------------- | -------------------------------------------------------------- |
| `--enable-map-align true`        | For RNA/scRNA pipelines, map-align should always be turned on. |
| `--enable-map-align-output true` | Optionally save the output BAM (default=false).                |

### Other single-cell RNA Prep options

To change the barcode or binning index positions, use `--scrna-barcode-position` and `--scrna-umi-position`. These settings should be provided in the form `<startPos>_<endPos>` for each barcode. Connect multiple barcode sequence positions with a '+'.

For example, a library with the cell-barcode split into three blocks of 9 bp separated by fixed linker sequences and an 8 bp BI would be set using: `--scrna-barcode-position 0_8+21_29+43_51`, and `--scrna-umi-position 52_59`.

The following table lists some optional settings:

| Option                          | Description                                                                                                                              |
| ------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------- |
| `--enable-single-cell-rna true` | Option to enable single-cell rna mode.                                                                                                   |
| `--scrna-barcode-position`      | See example above or refer to [scRNA](/dragen/dragen-v4.5/product-guides/dragen-v4.5/dragen-single-cell-pipeline/dragen-scrna-other.md). |
| `--scrna-umi-position`          | See example above or refer to [scRNA](/dragen/dragen-v4.5/product-guides/dragen-v4.5/dragen-single-cell-pipeline/dragen-scrna-other.md). |
| `--single-cell-threshold`       | Cell filtering can be set to \['fixed', 'ratio', or 'inflection'].                                                                       |
| `--scrna-barcode-sequence-list` | A known barcode sequence list can be optionally provided.                                                                                |
| `--umi-source`                  | Optionally override the default barcode/BI source, valid option include \['read1', 'read2', 'qname', 'fastq'].                           |

For more details on single-cell RNA options, refer to the [DRAGEN Single-Cell RNA User Guide](/dragen/dragen-v4.5/product-guides/dragen-v4.5/dragen-single-cell-pipeline/dragen-scrna-other.md).


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://help.connected.illumina.com/dragen/dragen-v4.5/product-guides/dragen-v4.5/dragen-recipes/other-scrna-prep.md?ask=<question>
```