For the complete documentation index, see llms.txt. This page is also available as Markdown.

Auto-Launch of DRAGEN TSO 500 Analysis on BioInsight Platform Core

Auto-launch Prerequisites and Workflow

*The BaseSpace Sequence Hub setting for run monitoring and storage must be selected on the instrument to use DRAGEN TSO 500 analysis auto-launch. For information on preparing your instrument for DRAGEN TSO 500 auto-launch, refer to the documentation for your instrument.

  1. Use BaseSpace Sequence Hub Run Planning tool or the sample sheet templates provided on the support page to create and export a sample sheet.

    1. If BaseSpace Run Planning tool is not available in your region, use the sample sheet template.

  2. Import the sample sheet to the instrument and start the sequencing run. Refer to Platform Core Auto-launch Sample Sheet Requirements for sample sheet guidance.

    1. Data is uploaded to BaseSpace Sequence Hub and then pushed to Platform Core. You can monitor the run in BaseSpace Sequence Hub.

    2. Analysis auto launches in Platform Core when sequencing and the upload completes. You can monitor the status of the analysis in BaseSpace Sequence Hub or Platform Core

    3. If necessary, you can requeue the analysis via BaseSpace Sequence Hub.

  3. View the analysis output results in either BaseSpace Sequence Hub or Platform Core.

BaseSpace Sequence Hub Requirements for Platform Core Auto-Launch

BaseSpace Run Planning tool is a multi-step workflow that generates a manual launch or auto-launch capable sample sheet for export and requires the following additional settings:

  • Access to BaseSpace Sequence Hub.

  • Platform Core Run Storage is enabled under BaseSpace Sequence Hub settings.

Refer to the BaseSpace Sequence Hub support site page for information on setting up a BaseSpace Sequence Hub project.

Requeue Analysis

You can requeue analysis of a run via the run's Summary page in BaseSpace Sequence Hub.

Refer to the BaseSpace Sequence Hub support site page for more information on requeuing an analysis.

Minimum Storage Requirements on Platform Core

Sequencing System
Minimum Disk Space (Gb)

NextSeq 500/550/550Dx (RUO) HO flow cell

350

NovaSeq 6000/6000Dx (RUO) SP Flow Cell

500

NovaSeq 6000/6000Dx (RUO) S1 Flow Cell

1100

NovaSeq 6000/6000Dx (RUO) S2 Flow Cell

2500

NovaSeq 6000/6000Dx (RUO) S4 Flow Cell

4300

NovaSeq X 1.5B

2000

NovaSeq X 10B

4300

NovaSeq X 25B

8400

NextSeq 1000/2000

350

Refer to the Software Registration page for information on how to manage accounts and subscriptions.

Guided Examples

Please review these guided examples of using DRAGEN TSO 500 Analysis Software with auto-launch on Platform Core:

Last updated

Was this helpful?