Infinium LCG Assay Manual v1.2
Last updated
Last updated
The Infinium LCG Assay Manual workflow includes the following functionality.
Preconfigured protocols to prepare 96 DNA samples for use with 8x1 LCG BeadChip products.
Automated calculation of sample and buffer volumes.
Automatic placement of samples when necessary.
Automatic step transition when required.
Automatic calculation or display of reagents at every step in the protocol.
Protocol Type = Sample Prep
Next Steps Configuration
Master Step Name = Select Infinium Kit-Infinium LCG v1.2
Step Type = No Outputs
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Waiting | Built-in | ||
Project | Project Name | Built-in |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Infinium LCG Kits | Text Dropdown | Required Field | Presets
|
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Collapse
Well Sort Order = Row
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in | ||
Project | Project Name | Built-in |
Master Step Name = Quantify DNA-Infinium PicoGreen v1.2
Step Type = Standard QC
Measurement Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
1X TE
Lambda DNA
PicoGreen dsDNA quantification reagent
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in | ||
Project | Project Name | Built-in |
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement Pattern = Row
Destination Containers
96 well plate
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
1X TE (mL) | Numeric | Read Only | |
1X TE for A1 (uL) | Numeric | Read Only | |
Lambda serial dilution instruction notes | Multiline Text | Read Only |
|
No. of QDNA Plates | Numeric Dropdown |
| |
PicoGreen (uL) | Numeric | Read Only | |
Sample QDNA Plate instruction notes | Multiline Text | Read Only |
|
Standard QDNA Plate instruction notes | Multiline Text | Read Only |
|
Stock Lambda DNA (ng/uL) | Numeric | ||
Stock Lambda DNA for A1 (uL) | Numeric | Read Only |
Step File Placeholders
Log - Automatically attached
Results File - Manually uploaded
Sample Table
Enable QC Flags = Yes
Sample Display Default = Collapse
Well Sort Order = Row
File Column Options
File Column Display = Show
File Attachment Method = Manual
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in |
Master Step Name = Amplify DNA-Infinium LCG v1.2
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
MA1-Infinium
Supplier = Illumina
Website = www.illumina.com
MSM-Infinium
Supplier = Illumina
Website = www.illumina.com
NaOH
RPM-Infinium
Supplier = Illumina
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Waiting | Built-in | ||
Project | Project Name | Built-in |
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Column
Placement Pattern = Same Shape
Destination Containers
96 well plate
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Comment | Multiline Text | ||
Instruction Notes | Multiline Text | Read Only | Default = Add 20 µl MA1 to each well of the MSA3 plate. Transfer 4 µl DNA sample from the DNA plate to the corresponding wells of the plate Add 4 µl 0.1N NaOH in to each sample well of the plate Add 68 μl RPM in to each sample well of the plate. Add 75 μl MSM in to each sample well of the plate Vortex at 1600 rpm for 1 minute, and then pulse centrifuge at 280 × g. |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Collapse
Well Sort Order = Row
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in | ||
Project | Project Name | Built-in |
Master Step Name = Incubate DNA-Infinium v1.2
Step Type = No Outputs
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Waiting | Built-in | ||
Project | Project Name | Built-in |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Comment | Multiline Text | ||
Instruction Notes | Multiline Text | Read Only | Default = Incubate the plate in the Illumina Hybridization Oven for 20–24 hours at 37°C. |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Collapse
Well Sort Order = Row
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Sample_Plate | Text | ||
Derived Sample | Sample_Well | Text |
Master Step Name = Fragment DNA-Infinium v1.2
Step Type = No Outputs
Reagent Kits
FMS-Infinium
Supplier = Illumina
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Waiting | Built-in | ||
Project | Project Name | Built-in |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Comment | Multiline Text | ||
Instruction Notes (HD Methylation & LCG) | Multiline Text | Read Only | Default = Add 50 μl FMS to each well of the plate. |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Collapse
Well Sort Order = Column
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Sample_Plate | Text | ||
Derived Sample | Sample_Well | Text |
Master Step Name = Precipitate DNA-Infinium v1.2
Step Type = No Outputs
Reagent Kits
100% 2-propanol
PM1-Infinium
Supplier = Illumina
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Column
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
100% 2-propanol Prep Date | Date | ||
Blue Pellet Presence | Toggle Switch | Default = None Set | |
Comment | Multiline Text | ||
Instruction Notes (HD Methylation & LCG) | Multiline Text | Read Only | Default = Add 100 μl PM1 to each well of the plate. Add 300 μl 100% 2-propanol to each well of the plate. |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Collapse
Well Sort Order = Column
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Sample_Plate | Text | ||
Derived Sample | Sample_Well | Text |
Master Step Name = Resuspend DNA-Infinium v1.2
Step Type = No Outputs
Reagent Kits
RA1-Infinium
Supplier = Illumina
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Column
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Comment | Multiline Text | ||
Instruction Notes (HD Methylation & LCG) | Multiline Text | Read Only | Default = Add 46 µl RA1 to each well of the plate |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Collapse
Well Sort Order = Column
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Sample_Plate | Text | ||
Derived Sample | Sample_Well | Text |
Protocol Type = Sample Prep
Next Steps Configuration
Master Step Name = Hybridize DNA to BeadChip-Infinium v1.2
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
PB2-Infinium
Supplier = Illumina
Website = www.illumina.com
XC4-Infinium
Supplier = Illumina
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only |
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement Pattern = Row
Destination Containers
8x1 LCG BeadChip
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Comment | Multiline Text | ||
LCG Instruction Notes | Multiline Text | Read Only | Default = Transfer 35 µl each sample from the plate to the appropriate section of the BeadChip. |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Collapse
Well Sort Order = Row
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Sample_Plate | Text | ||
Derived Sample | Sample_Well | Text |
Master Step Name = Wash BeadChip-Infinium v1.2
Step Type = No Outputs
Reagent Kits
PB1-Infinium
Supplier = Illumina
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample_Plate | Text | ||
Derived Sample | Sample_Well | Text |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Comment | Multiline Text | ||
Instruction Notes | Multiline Text | Read Only | Default = Fill two wash dish with 200ml PB1 each and labelled Wash 1 and Wash2 |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Collapse
Well Sort Order = Row
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | BeadChip Barcode | Text | Read Only | |
Derived Sample | BeadChip Position | Text | Read Only | |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Sample_Plate | Text | ||
Derived Sample | Sample_Well | Text |
Master Step Name = Extend and Stain BeadChip-Infinium v1.2
Step Type = No Outputs
Reagent Kits
70% EtOH
ATM-Infinium
Supplier = Illumina
Website = www.illumina.com
EML-Infinium
Supplier = Illumina
Website = www.illumina.com
LX1-Infinium
Supplier = Illumina
Website = www.illumina.com
LX2-Infinium
Supplier = Illumina
Website = www.illumina.com
PB1-Infinium
Supplier = Illumina
Website = www.illumina.com
RA1-Infinium
Supplier = Illumina
Website = www.illumina.com
SML-Infinium
Supplier = Illumina
Website = www.illumina.com
XC3-Infinium
Supplier = Illumina
Website = www.illumina.com
XC4-Infinium
Supplier = Illumina
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample_Plate | Text | ||
Derived Sample | Sample_Well | Text |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Comment | Multiline Text | ||
Extend Instruction Notes | Multiline Text | Read Only | Default = Without allowing pipette tips to touch BeadChip surfaces, fill the reservoir of each flow-through chamber as follows: 150 µl RA1. Incubate for 30 seconds. Repeat 5 times. 225 µl LX1. Incubate for 10 minutes.Repeat once. 225 µl LX2. Incubate for 10 minutes. Repeat once. 300 µl EML. Incubate for 15 minutes. 250 µl 95% formamide/1 mM EDTA. Incubate for 1 minute. Repeat twice.Incubate 5 minutes. Set the the chamber rack temperature to the temperature indicated on the SML tube. 250 µl XC3. Incubate for 1 minute. Repeat twice. |
Stain Instruction Notes | Multiline Text | Read Only | Default = Fill the reservoir of each flow-through chamber as follows: 250 µl SML. Incubate for 10 minutes. 250 µl XC3. Incubate for 1 minute. Repeat twice. Wait 5 minutes. 250 µl ATM. Incubate for 10 minutes. 250 µl XC3. Incubate for 1 minute. Repeat twice. Wait 5 minutes. g 250 µl SML. Incubate for 10 minutes. 250 µl XC3. Incubate for 1 minute. Repeat twice. Wait 5 minutes. 250 µl ATM. Incubate for 10 minutes. 250 µl XC3. Incubate for 1 minute. Repeat twice. Wait 5 minutes. 250 µl SML. Incubate for 10 minutes. 250 µl XC3. Incubate for 1 minute. Repeat twice. Wait 5 minutes. |
Wash and Coat Beadships Instruction Notes | Multiline Text | Read Only | Default = Add 310 ml PB1 to the PB1 wash dish. Add 310 ml XC4 to the XC4 wash dish |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Collapse
Well Sort Order = Row
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | Array Instrument | Text | Default = iScan | |
Derived Sample | BeadChip Barcode | Text | Read Only | |
Derived Sample | BeadChip Position | Text | Read Only | |
Derived Sample | DNA Plate Barcode | Text | Read Only | |
Derived Sample | Infinium Kit Name | Text | Read Only | |
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Sample_Plate | Text | ||
Derived Sample | Sample_Well | Text |