Upgrading a configuration package/manifest file for compatibility with Config Slicer v3.0.x
If running Config Slicer v3.0.x against a configuration package or manifest file that was generated with a pre-3.0 version of Config Slicer, an error message displays.
Scenario 1: Out-of-Date Configuration Package
In this scenario the error message will resemble the following:
Copy
SOLUTION:
Upgrade the configuration package file by running upgrade-config-slice.jar against it.
This jar file should be located in the same directory as Config Slicer (/tools/config-slicer).
The upgrade script will save an upgraded copy of the configuration package file (to the same directory), which can be inspected and imported.
Example:
Copy
To upgrade a manifest file at the same time, simply add it to the script as a second argument:
Copy
Scenario 2: Out-of-Date Manifest File with no Corresponding Configuration Package
In this scenario the error message resembles the following:
Copy
SOLUTION:
This upgrade process is a little more involved:
Extract the list of process types from the manifest file .
Format them as parameters to Config Slicer's custom manifest generation for process types.
For example, assuming we extracted the process types Process Type 1 and Process Type 2 in step 1, the following command would be used:
Copy
Run the custom manifest generation.
Take the list of analyte UDFs and ResultFile UDTs from the manifest file that was generated and add them to the old manifest file .
Add the following line of text to the top of the old manifest file:
Copy