LogoLogo
Illumina KnowledgeIllumina SupportSign In
Clarity LIMS Software
  • Home
Clarity LIMS Software
  • Announcements
  • Clarity LIMS
    • Clarity & LabLink
  • API and Database
    • API Portal
      • REST
        • REST General Concepts
        • REST Web Services
        • HTTP Response Codes and Errors
        • XML UTF-8 Character Encoding
        • Requesting API Version Information
        • Viewing Paginated List Resources
        • Filtering List Resources
        • Working with User-Defined Fields (UDF) and Types (UDT)
        • Traversing a Genealogy
        • Working with Batch Resources
      • Getting Started with API
        • Understanding API Terminology (LIMS v5 and later)
        • API-Based URIs (LIMS v4 and later)
        • Development Prerequisites
        • Structure of REST Resources
        • The Life Cycle of a Sample: Stages Versus Steps
        • Integrating Scripts
      • Automation
        • Automation Triggers and Command Line Calls
        • Automation Execution Environment
        • Supported Command Line Interpreters
        • Automation Channels
        • Error Handling
        • Automation Tokens
          • Derived Sample Automation Tokens
          • Step Automation Tokens
          • Project Automation Tokens
        • Automation Testing
        • Troubleshooting Automation
      • Tips and Tricks
        • Accessing Step UDFs from a different Step
        • Obfuscating Sensitive Data in Scripts
        • Integrating Clarity LIMS with Upstream Sample Accessioning Systems
        • Creating Samples and Projects via the API
        • Displaying Files From an Earlier Step
        • Transitioning Output Artifacts into the Next Step
        • Determining the Workflow(s) to Which a Sample is Assigned
        • Standardizing Sample Naming via the API
        • Copying UDF Values from Source to Destination
        • Updating Preset Value of a Step UDF through API
        • Automating BCL Conversion
        • Finding QC Flags in Aggregate QC (Library Validation) via REST API
        • Setting the Value of a QC Flag on an Artifact
        • Creating Notifications When Files are Added via LabLink
        • Remote HTTP Filestore Setup
      • Cookbook
        • Get Started with the Cookbook
          • Tips and Troubleshooting
          • Obtain and Use the REST API Utility Classes
        • Work with EPP/Automation and Files
          • Automation Trigger Configuration
          • Process Execution with EPP/Automation Support
        • Work with Submitted Samples
          • Adding Samples to the System
          • Renaming Samples
          • Assigning Samples to Workflows
          • Updating Sample Information
          • Show the Relationship Between Samples and Analyte Artifacts (Derived Samples)
        • Work with Containers
          • Add an Empty Container to the System
          • Find the Contents of a Well Location in a Container
          • Filter Containers by Name
        • Work with Derived Sample Automations
          • Remove Samples from Workflows
          • Requeue Samples
          • Rearray Samples
        • Work with Process/Step Outputs
          • Update UDF/Custom Field Values for a Derived Sample Output
          • Rename Derived Samples Using the API
          • Find the Container Location of a Derived Sample
          • Traverse a Pooled and Demultiplexed Sample History/Genealogy
          • View the Inputs and Outputs of a Process/Step
        • Work with Projects and Accounts
          • Remove Information from a Project
          • Add a New Project to the System with UDF/Custom Field Value
          • Get a Project Name
          • Find an Account Registered in the System
          • Update Contact (User and Client) Information
        • Work with Multiplexing
          • Find the Index Sequence for a Reagent Label
          • Demultiplexing
          • Pool Samples with Reagent Labels
          • Apply Reagent Labels with REST
          • Apply Reagent Labels When Samples are Imported
          • Apply Reagent Labels by Adding Reagents to Samples
        • Working with User Defined Fields/Custom Fields
          • About UDFs/Custom Fields and UDTs
          • Performing Post-Step Calculations with Custom Fields/UDFs
        • Work with Processes/Steps
          • Filter Processes by Date and Type
          • Find Terminal Processes/Steps
          • Run a Process/Step
          • Update UDF/Custom Field Information for a Process/Step
          • Work with the Steps Pooling Endpoint
        • Work with Batch Resources
          • Introduction to Batch Resources
          • Update UDF/Custom Field Information with Batch Operations
          • Retrieve Multiple Entities with a Single API Interaction
          • Select the Optimal Batch Size
        • Work with Files
          • Attach a File with REST and Python
          • Attach Files Located Outside the Default File Storage Repository
          • Attach a File to a File Placeholder with REST
        • Work with Controls
          • Automated Removal of Controls from a Workflow
      • Application Examples
        • Python API Library (glsapiutil.py) Location
        • Scripts That Help Automate Steps
          • Route Artifacts Based Off a Template File
          • Invoking bcl2fastq from BCL Conversion and Demultiplexing Step
          • Email Notifications
          • Finishing the Current Step and Starting the Next
          • Adding Downstream Samples to Additional Workflows
          • Advancing/Completing a Protocol Step via the API
          • Setting a Default Next Action
          • Automatic Placement of Samples Based on Input Plate Map (Multiple Plates)
          • Automatic Placement of Samples Based on Input Plate Map
          • Publishing Files to LabLink
          • Automatic Pooling Based on a Sample UDF/Custom Field
          • Completing a Step Programmatically
          • Automatic Sample Placement into Existing Containers
          • Routing Output Artifacts to Specific Workflows/Stages
          • Creating Multiple Containers / Types for Placement
          • Starting a Protocol Step via the API
          • Setting Quality Control Flags
          • Applying Indexing Patterns to Containers Automatically
          • Assignment of Sample Next Steps Based On a UDF
          • Parsing Metadata into UDFs (BCL Conversion and Demultiplexing)
        • Scripts That Validate Step Contents
          • Validating Process/Step Level UDFs
          • Checking That Containers Are Named Appropriately
          • Checking for Index Clashes Based on Index Sequence
          • Validating Illumina TruSeq Index Adapter Combinations
        • Scripts Triggered Outside of Workflows/Steps
          • Repurposing a Process to Upload Indexes
          • Adding Users in Bulk
          • Moving Reagent Kits & Lots to New Clarity LIMS Server
          • Programatically Importing the Sample Submission Excel File
          • Generating an MS Excel Sample Submission Spreadsheet
          • Assigning Samples to New Workflows
        • Miscellaneous Scripts
          • Illumina LIMS Integration
          • Generating a Hierarchical Sample History
          • Protocol-based Permissions
          • Self-Incremental Counters
          • Generic CSV Parser Template (Python)
          • Renaming Samples to Add an Internal ID
          • Creating Custom Sample Sheets
          • Copying Output UDFs to Submitted Samples
          • Parsing Sequencing Meta-Data into Clarity LIMS
          • Submit to a Compute Cluster via PBS
          • Downloading a File and PDF Image Extraction
        • Resources and References
          • Understanding LIMS ID Prefixes
          • Container States
          • Useful Tools
          • Unsupported Artifact Types
          • Unsupported Process Types
          • Suggested Reading
          • API Training Videos
  • Illumina Preset Protocols
    • IPP v2.10
      • Release Notes
      • Installation and User Configuration
      • Manual Upgrade
    • IPP v2.9
      • Release Notes
      • Installation and User Configuration
    • IPP v2.8
      • Release Notes
      • Installation and User Configuration
      • Manual Upgrade
    • IPP v2.7
      • Release Notes
      • Installation and User Configuration
    • IPP v2.6
      • Release Notes
      • Installation and User Configuration
      • Manual Upgrade
  • Sample Prep
    • QC and Sample Prep
      • DNA Initial QC 5.1.2
      • RNA Initial QC 5.1.2
      • Library Validation QC 5.1.2
  • Library Prep
    • AmpliSeq for Illumina
      • BRCA Panel
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Cancer HotSpot Panel v2
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Childhood Cancer Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Comprehensive Cancer Panel
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Comprehensive Panel v3
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Custom DNA Panel
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Focus Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Immune Repertoire Panel
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Immune Response Panel
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Myeloid Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • TCR beta-SR Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
      • Transcriptome Human Gene Expression Panel
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
    • Library Prep Validation
    • Nextera
      • Nextera Mate Pair v1.0
      • Nextera Rapid Capture Custom Enrichment v2.0
      • Nextera XT v2.0
    • Targeted Enrichment
      • Illumina DNA Prep with Enrichment (S) Tagmentation v1.2
      • Illumina RNA Prep with Enrichment (L) Tagmentation v1.1
    • TruSeq
      • TruSeq ChIP-Seq v1.0
      • TruSeq Custom Amplicon v1.0
      • TruSeq DNA Exome v2.0
      • TruSeq DNA PCR-Free v2.0
      • TruSeq Methyl Capture EPIC v2.0
      • TruSeq Nano DNA v1.0
      • TruSeq RNA Access v2.0
      • TruSeq RNA Exome v1.0
      • TruSeq Small RNA v1.0
      • TruSeq Stranded mRNA v2.0
    • TruSight
      • TruSight Oncology 500 ctDNA v1.1
      • TruSight Oncology 500 HT v1.1
      • TruSight Oncology 500 v1.1
      • TruSight Tumor 170 v2.0
    • Other DNA Protocols
      • Illumina DNA PCR-Free Library Prep Manual v1.1
      • Illumina DNA Prep (M) Tagmentation v1.0
    • Other RNA Protocols
      • Illumina Stranded mRNA Prep Ligation 1.1
      • Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus v1.1
  • iLASS & Infinium Arrays
    • iLASS
      • iLASS Infinium Genotyping v1.1
        • iLASS Infinium Batch DNA v1.1
        • iLASS Infinium Genotyping Assay v1.1
        • iLASS Infinium Genotyping with PGx Assay v1.1
      • iLASS Infinium Genotyping v1.0
        • iLASS Infinium Genotyping Assay v1.0
        • iLASS Infinium Genotyping with PGx Assay v1.0
    • Infinium Arrays
      • Infinium HD Methylation Assay Manual v1.2
      • Infinium HTS Assay Manual v1.2
      • Infinium LCG Assay Manual v1.2
      • Infinium XT Assay Manual v1.2
      • GenomeStudio v1.0
  • Applications
    • IGA
      • IGA v2.1
        • IGA Library Prep Automated v2.1
        • IGA NovaSeq Sequencing v2.1
    • Viral Pathogen Protocols
      • CDC COVID-19 RT-PCR
        • Sort Specimens to Extraction v1.1
        • Qiagen QIAamp DSP Viral RNA Mini Kit v1.1
        • Qiagen EZ1 Advanced XL v1.1
        • Roche MagNA Pure LC v1.1
        • Roche MagNA Pure Compact v1.1
        • Roche MagNA Pure 96 v1.1
        • bioMerieux NucliSENS easyMAG Instrument v1.1
        • bioMerieux EMAG Instrument v1.1
        • Real-Time RT-PCR Prep v1.1
      • Illumina COVIDSeq v1.6
      • Respiratory Virus Panel v1.0
  • Instruments & Integrations
    • Compatibility
    • Integration Properties
      • Integration Properties Details
    • Clarity LIMS Product Analytics
      • Supported Workflows
      • Workflow Customization
      • Clarity LIMS Product Analytics v1.4.0
        • Configuration
      • Clarity LIMS Product Analytics v1.3.1
        • Configuration
      • Clarity LIMS Product Analytics v1.3.0
        • Configuration
      • Clarity LIMS Product Analytics v1.2.0
        • Configuration
    • Illumina Run Manager
      • Illumina Run Manager v1.0.0
        • Installation and User Interaction
    • iScan
      • iScan System
      • iScan v1.2.0
        • Release Notes
        • BeadChip Accessioning, Imaging, and Analysis
      • iScan v1.1.0
        • Release Notes
        • BeadChip Accessioning, Imaging, and Analysis
      • iScan System v1.0
    • iSeq 100 Run Setup v1.0
    • MiniSeq v1.0
    • MiSeq
      • MiSeq v8.3.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • MiSeq v8.2.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
    • MiSeq i100 (On-Prem)
      • MiSeq i100 On-Prem v1.0.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • MiSeq i100 (Hosted)
      • MiSeq i100 v1.0.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • MiSeqDx
      • MiSeqDx Sample Sheet Generation (v1.11.0 and later)
      • MiSeqDx v1.11.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • MiSeqDx v1.10.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Sample Sheet Generation
        • Manual Upgrade
    • Next Generation Sequencing Package
      • Release Notes
        • NGS Extensions v5.25.0
        • NGS Extensions v5.24.0
        • NGS Extensions v5.23.0
      • Accession Kit Lots
      • Auto-Placement of Reagent Indexes
      • Compute Replicate Average
      • Copy UDFs
      • Initialize Artifact UDFs
      • Label Non-Labeled Outputs
      • Linear Regression Calculation
      • Normalization Buffer Volumes
      • Process Summary Report
      • Routing Script
      • Set UDF
      • Validate Complete Plate
      • Validate Sample Count
      • Validate Unique Indexes
    • NextSeq 500/550
      • NextSeq 500/550 v2.5.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
      • NextSeq 500/550 v2.4.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NextSeq 500/550 v2.3.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NextSeq 1000/2000 (Hosted)
      • NextSeq 1000/2000 v2.5.1
        • Release Notes
      • NextSeq 1000/2000 v2.5.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
      • NextSeq 1000/2000 v2.4.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NextSeq 1000/2000 (On-Prem)
      • NextSeq 1000/2000 On-Prem v1.0.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq 6000 (API-based)
      • NovaSeq 6000 API-based v3.7.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NovaSeq 6000 API-based v3.6.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
    • NovaSeq 6000 (File-based)
      • NovaSeq 6000 File-based v2.6.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NovaSeq 6000 File-based v2.5.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq 6000Dx (API-based)
      • NovaSeq 6000Dx API-based v1.3.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NovaSeq 6000Dx API-based v1.2.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq X Series (Hosted)
      • NovaSeq X Series v1.3.0
        • Release Notes
        • Configuration
        • Manual Upgrade
      • NovaSeq X Series v1.2.1
        • Release Notes
      • NovaSeq X Series v1.2.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
      • NovaSeq X Series v1.1.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq X Series (On-Prem)
      • NovaSeq X Series On-Prem v1.0.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • References
      • Configure Multiple Identical netPathPrefixSearch Values
      • Configure Support for Samples Having Duplicate Names with Different Indexes
      • Illumina Instrument Sample Sheets
      • Terminology
  • Integration Toolkits
    • Lab Instrument Toolkit
      • Template File Generator
        • Creating Template Files
        • Template File Contents
        • Template File Generator Troubleshooting
      • Add Blank Lines
      • Convert CSV to Excel
      • Parse CSV
      • Name Matching XML Parser
      • Sample Placement Helper
    • Lab Logic Toolkit
      • Working with Lab Logic Toolkit
        • Data Collection Entities
        • Failing a Script
        • Mapping Field Types
        • Non-UDF/Custom Field Properties
        • Setting QC Flags
        • Setting Next Actions
        • Specifying Custom Fields
        • Working with Submitted Samples
        • Working with Containers
      • Lab Logic Toolkit Script Examples
        • Comparing Stop/Start Dates and Times with LLTK
      • Lab Logic Toolkit FAQ
  • Known Issues
    • Integration
      • Sample Sheet Generation Issue and CLPA Issues When Samples Have Been Assigned QC Flag Prior to Entering Steps
  • Security Bulletin
    • Investigation of OpenSSH vulnerability with Clarity LIMS
  • Resources
    • Third Party Software Information
  • Others
    • Revision History
Powered by GitBook
On this page
  • Prerequisites and Assumptions
  • Workflows, Protocols, and Steps
  • Library Prep Validation v2.3.4 Workflow
  • NovaSeqDx v1.2 Workflow
  • Validation Workflow
  • Protocol 1: Run Format (NovaSeqDx v1.2)
  • Step 1. Define Run Format (NovaSeqDx v1.2)
  • Protocol 2: NovaSeqDx Standard (NovaSeqDx v1.2)
  • Step 1: Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2)
  • Step 2: Dilute and Denature (NovaSeqDx v1.2)
  • Protocol 3: NovaSeqDx Xp (NovaSeqDx v1.2)
  • Step 1: Make Bulk Pool for NovaSeqDx Xp (NovaSeqDx v1.2)
  • Step 2: Dilute, Denature & ExAmp (NovaSeqDx v1.2)
  • Step 3: Load to Flowcell (NovaSeqDx v1.2)
  • Protocol 4: AUTOMATED - NovaSeqDx Run (NovaSeqDx v1.2)
  • Step 1: AUTOMATED - NovaSeqDx Run (NovaSeqDx v1.2)
  • Sample Sheet Generation
  • NovaSeq 6000Dx Run
  • Components Installed
  • NovaSeq 6000Dx Integration RPM Components
  • Properties
  • Reagent Categories/Label Groups
  • Reagent Kits
  • Container Types
  • NVOS Configuration
  • Routing Script Requirements
  • Configure autoComplete Properties
  • Enable/Disable autoComplete Properties
  • autoComplete Properties
  • Rules and Constraints

Was this helpful?

Export as PDF
  1. Instruments & Integrations
  2. NovaSeq 6000Dx (API-based)
  3. NovaSeq 6000Dx API-based v1.3.0

Configuration

PreviousInstallationNextUser Interaction, Validation and Troubleshooting

Last updated 4 months ago

Was this helpful?

Illumina NovaSeqDx Integration Package v1.3.0 supports the integration of Clarity LIMS to Illumina NovaSeq 6000Dx instruments.

For instructions on user interaction for each step, validating and troubleshooting Illumina NovaSeqDx Integration Package v1.3.0, refer to .

The configuration provided in this integration has been established to support NovaSeq 6000Dx lab processes. Any configuration changes to protocols or workflows—including renaming protocols, steps, and fields—could break the process.

Prerequisites and Assumptions

Samples enter the NovaSeqDx v1.2 workflow as normalized libraries. It is assumed that the following steps have completed before samples are assigned to the workflow:

  • Samples have been accessioned into the Clarity LIMS.

  • Samples have been run through QC and library prep.

  • Samples have been normalized, and the value is captured in a field called Normalized Molarity (nM).

For more information on sample accessioning, refer to the following sections of the Getting Started section of the :

  • Sample Accessioning

  • Using Sample Lists to Upload and Modify Samples

You can assign samples to workflows automatically, using a routing script, or manually—from the Projects & Samples dashboard. Refer to Assign and Process Samples in the .

Workflows, Protocols, and Steps

The Illumina NovaSeq 6000Dx Integration Package v1.3.0 includes the following workflows:

  • NovaSeqDx v1.2

  • Library Prep Validation v2.3.4 (optional, but recommended for validation purposes)

The following describes the protocols and steps included in these workflows.

Library Prep Validation v2.3.4 Workflow

Protocol: Library Prep Validation v2.3.4

Purpose:

  • Included for validation purposes only, this protocol models the library prep steps required to advance samples to the Run Format (NovaSeqDx v1.2) protocol.

  • The protocol contains a single step - Library Prep Validation v2.3.4. After this step, a routing script sends the samples to the first step of the NovaSeqDx v1.2 workflow - Define Run Format (NovaSeqDx v1.2).

Steps:

  1. Library Prep Validation v2.3.4

NovaSeqDx v1.2 Workflow

Protocol 1: Run Format (NovaSeqDx v1.2)

Purpose:

  • Allows for the assignment of per sample values for the following properties:

    • NovaSeqDx Run Mode: Select either RUO or DX.

    • Loading Workflow Type: Select either NovaSeq Standard or NovaSeq Xp.

    • Normalized Molarity (nM): Enter a value for each sample.

    • Flowcell Type: Select from options SP, S1, S2, or S4.

    • Final Loading Concentration (pM): Select from options 225 (PCR-free workflows) or 400 (Nano workflows), or enter a different value.

  • Compares the Normalized Molarity value of each sample with the Minimum Molarity value.

  • Validates user selection on NovaSeqDx Run Mode, Loading Workflow Type and Flowcell Type.

  • Routing script sends samples to the NovaSeqDx Standard or NovaSeqDx Xp protocol, according to the selected Loading Workflow Type.

  • Samples with Normalized Molarity less than Minimum Molarity are removed from the workflow.

Steps:

  1. Define Run Format (NovaSeqDx v1.2)

Protocol 2: NovaSeqDx Standard (NovaSeqDx v1.2)

Purpose:

  • Samples are pooled and added to the library tube in preparation for the NovaSeq 6000Dx run. The run setup information is validated and a sample sheet is generated.

  • Routing script sends the library tube to the AUTOMATED - NovaSeqDx Run (NovaSeqDx v1.2) protocol.

Steps:

  1. Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2)

  2. Dilute and Denature (NovaSeqDx v1.2)

Protocol 3: NovaSeqDx Xp (NovaSeqDx v1.2)

Purpose:

  • Samples are pooled and added to lanes on the NovaSeq 6000Dx flow cell. The option selected in the Define Run Format (NovaSeqDx v1.2) step determines the flow cell type. The run setup information is validated and a sample sheet is generated.

  • Routing script sends flow cell to the AUTOMATED - NovaSeqDx Run (NovaSeqDx v1.2) protocol.

Steps:

  1. Make Bulk Pool for NovaSeqDx Xp (NovaSeqDx v1.2)

  2. Dilute, Denature & ExAmp (NovaSeqDx v1.2)

  3. Load to Flowcell (NovaSeqDx v1.2)

Protocol 4: AUTOMATED - NovaSeqDx Run (NovaSeqDx v1.2)

Purpose:

  • All samples complete the workflow by going through this protocol.

  • This protocol contains one fully automated step.

⚠ Do not add samples to the Ice Bucket or start the step. The integration starts the step automatically.

Steps:

  1. AUTOMATED - NovaSeqDx Run (NovaSeqDx v1.2)

Validation Workflow

Protocol 1: Run Format (NovaSeqDx v1.2)

This protocol sets the Loading Workflow Type and allows the choice of the appropriate Flowcell Type and Final Loading Concentration (pM). After the protocol, a routing script sends the normalized libraries to either the NovaSeqDx Standard (NovaSeqDx v1.2) or the NovaSeqDx Xp (NovaSeqDx v1.2) protocol.

This protocol contains one step: Define Run Format (NovaSeqDx v1.2).

Step 1. Define Run Format (NovaSeqDx v1.2)

  • Step input: Normalized Template Plate (NTP, normalized libraries)

  • Step output: None

Set Next Steps Automation

Automatically triggered on exit of the Record Details screen, this automation completes the following actions:

  • Sets the next step for samples to REMOVE:

    nextStep = ::REMOVE::
  • Checks NovaSeqDx Run Mode, Loading Workflow Type, and Flowcell Type. Only the NovaSeq Standard with the S2/S4 flow cell is supported for the NovaSeqDx Run Mode:

    if (input.::NovaSeqDx Run Mode:: == ::DX::) {
        if (input.::Loading Workflow Type:: == ::NovaSeq Xp::) {
            fail(::Invalid option selected. NovaSeq Standard shall be selected for DX mode.::);
        };
        if (input.::Flowcell Type:: == ::SP:: || input.::Flowcell Type:: == ::S1::) {
            fail(::Invalid option selected. Only S2 or S4 flowcell shall be selected for DX mode.::);
        };
    };
  • Calculates the Minimum Molarity with the following formula:

    input.::Minimum Molarity (nM):: = (5 * input.::Final Loading Concentration (pM)::)/1000
  • Checks Normalized Molarity value. For samples with no Normalized Molarity value (e.g., empty value, not including 0), generates an error message informing that the field cannot be empty:

    if (!input.hasValue(::Normalized Molarity (nM)::)) {
        fail(::The Normalized Molarity cannot be empty.::) ;
    }
  • Compares the Normalized Molarity value of each sample with the Minimum Molarity value. If the Normalized Molarity value is lower than the Minimum Molarity value, this sets the Loading Workflow Type of the sample to [Remove from workflow]. The automation also records a message in the Warning field for the sample:

    else if (input.::Normalized Molarity (nM):: < input.::Minimum Molarity (nM)::) {
        input.::Warning:: = ::The Normalized Molarity is too low.::;
        input.::Loading Workflow Type:: = ::[Remove from workflow]::;
    } else {
        input.::Warning:: = ::n/a::
    }

    At this point, the following options are available:

    • Correct the NovaSeqDx Run Mode and Normalized Molarity value on the Record Details screen. Edit the Loading Workflow Type field and set it to NovaSeq Standard or NovaSeq Xp, as applicable.

    • Complete the protocol without correcting the Normalized Molarity value. In this case, those samples are removed from the workflow.

Routing Script Automation

Automatically triggered on exit of the step, this automation invokes the changeWorkflow script, which routes step inputs appropriately.

  • Samples with Loading Workflow Type field value = NovaSeq Standard are routed to the NovaSeqDx v1.2 workflow. Then, the samples are queued for the Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2) step.

  • Samples with Loading Workflow Type field value = NovaSeq Xp are routed to the NovaSeqDx v1.2 workflow. Then, the samples are queued for the Make Bulk Pool for NovaSeqDx Xp (NovaSeqDx v1.2) step.

Default automation command line is as follows.

bash -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar
-u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \
\
--FIELD_NAME 'Loading Workflow Type' \
--FIELD_VALUE 'NovaSeq Standard' \
--WORKFLOW 'NovaSeqDx v1.2' \
--STEP 'Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2)' \
--INPUTS_OR_OUTPUTS 'INPUTS' \
\
--FIELD_NAME 'Loading Workflow Type' \
--FIELD_VALUE 'NovaSeq Xp' \
--WORKFLOW 'NovaSeqDx v1.2' \
--STEP 'Make Bulk Pool for NovaSeqDx Xp (NovaSeqDx v1.2)' \
--INPUTS_OR_OUTPUTS 'INPUTS'"

Master Step Fields

There are four fields defined on the Define Run Format (NovaSeqDx v1.2) master step.

The following table lists field configuration details.

Define Run Format (NovaSeqDx v1.2) Master Step Field Configuration

Field Name

Field Type

Options

Additional Options and Dropdown Items

Comment

Multiline Text

None

Flowcell Type

Text Dropdown

  • Required Field

  • Custom Entries

Presets

  • SP

  • S1

  • S2

  • S4

Instruction

Text

  • Read Only

Default

  • Add Flowcell Type, Loading Workflow Type, and NovaSeqDx Run Mode

Loading Workflow Type

Text Dropdown

  • Required Field

Presets

  • NovaSeq Standard

  • NovaSeq Xp

Global Fields

The following table lists the global custom fields that are configured to display on the Define Run Format (NovaSeqDx v1.2) step.

Global Field Configuration (Derived Sample)

Field Name

Field Type

Options

Additional Options and Dropdown Items

Adjusted Per Sample Volume (ul)

Numeric

  • Read Only

  • Decimal places displayed = 2

Final Loading Concentration (pM)

Numeric Dropdown

  • Required Field

  • Custom Entries

  • Presets

    • 225

    • 400

  • Decimal places displayed = 0

Flowcell Type

Text Dropdown

  • Required Field

  • Presets

    • SP

    • S1

    • S2

    • S4

Loading Workflow Type

Text Dropdown

  • Required Field

  • Presets

    • NovaSeq Standard

    • NovaSeq Xp

    • [Remove from workflow]

Minimum Molarity (nM)

Numeric

  • Decimal places displayed = 2

Normalized Molarity (nM)

Numeric

  • Decimal places displayed = 2

NovaSeqDx Run Mode

Text Dropdown

  • Required Field

  • Presets

    • DX

    • RUO

Per Sample Volume (ul)

Numeric

  • Read Only

  • Decimal places displayed = 2

Warning

Text Dropdown

  • Read Only

  • Custom Entries

  • Presets

    • The Normalized Molarity (nM) is too low.

    • n/a

Protocol 2: NovaSeqDx Standard (NovaSeqDx v1.2)

Samples are routed to this protocol when their Loading Workflow Type value is set to NovaSeq Standard. Samples are pooled and added to a library tube in preparation for the NovaSeqDx Run.

At the end of this protocol, a routing script sends the library tube to the AUTOMATED - NovaSeqDx Run (NovaSeqDx v1.2) protocol.

This protocol contains the following two steps:

  • Step 1: Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2)

  • Step 2: Dilute and Denature (NovaSeqDx v1.2)

Step 1: Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2)

In this step, libraries are placed manually into a single pool. Resuspension buffer and reagents are added.

Create only one pool per step.

  • Step input: NTP (normalized libraries)

  • Step output: Bulk pool

Validate Unique Indexes automation is not used. The Clarity LIMS configuration for pooling handles this functionality.

Validate Single NovaSeqDx Run Mode Automation

The Validate Single NovaSeqDx Run Mode automation is triggered on entry of the step. The following automation checks that all input samples have the same NovaSeqDx Run Mode assigned:

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar \
script:validate_same_analyte_udf_value_for_all_inputs \
-i {stepURI:v2} \
-u {username} \
-p {password} \
-l {compoundOutputFileLuid1} \
-f 'NovaSeqDx Run Mode'"
Validate Inputs Flowcell Type and Single Pool Automation

Automatically triggered on exit of the Pooling screen, this automation completes the following actions:

  • Checks that all samples in the pool have the same Flowcell Type assigned to them.

  • Checks that only one pool has been created.

  • Changes the value of error and logging messages to reference the type of pool passed as bulk pool.

/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar \
script:validate_flowcell_for_input_pools \
-i {stepURI:v2} \
-u {username} \
-p {password} \
-l {compoundOutputFileLuid1} \
-validateSingleOutput true \
-poolType bulk"
Calculate Volumes Automation

Automatically triggered when you select the Calculate Volumes button on the Record Details screen, this automation completes the following actions:

  • Calculates the number of samples in the pool.

    step.::Number of Samples in Pool:: = step.::Number of Samples in Pool:: + 1
  • Sets the value of the Bulk Pool Volume (ul), and PhiX Volume (ul) field based on the selected Flowcell Type.

    step.::PhiX Volume (ul):: = !step.hasValue(::% PhiX (2.5nM) Spike-In::) ? 0 : step.::% PhiX (2.5nM) Spike-In::;
    if (input.::Flowcell Type:: == ::SP::) {
        step.::Bulk Pool Volume (ul):: = step.::Number of Flowcells to Sequence:: * 100;
        step.::PhiX Volume (ul):: *= 0.6
    };
    if (input.::Flowcell Type:: == ::S1::) {
        step.::Bulk Pool Volume (ul):: = step.::Number of Flowcells to Sequence:: * 100;
        step.::PhiX Volume (ul):: *= 0.6
    };
    if (input.::Flowcell Type:: == ::S2::) {
        step.::Bulk Pool Volume (ul):: = step.::Number of Flowcells to Sequence:: * 150;
        step.::PhiX Volume (ul):: *= 0.9
    };
    if (input.::Flowcell Type:: == ::S4::) {
        step.::Bulk Pool Volume (ul):: = step.::Number of Flowcells to Sequence:: * 310;
        step.::PhiX Volume (ul):: *= 1.9
    };
    if (step.::PhiX Volume (ul):: == 0) {
        step.::PhiX Volume (ul):: = ::::
    };
  • Calculates the Per Sample Volume (ul) to be added to the pool.

    input.::Per Sample Volume (ul):: = ( ( (input.::Final Loading Concentration (pM):: * 5 / 1000) / input.::Normalized Molarity (nM):: ) * step.::Bulk Pool Volume (ul):: ) / step.::Number of Samples in Pool::

    ⚠ For accurate pipetting of each sample in a pool for sequencing, the Per Sample Volume (ul) value must be equal to or higher than the Minimum Per Sample Volume (ul). The default value (set at 5) can be edited.

    Assuming the default Minimum Per Sample Volume (ul) value of 5, this automation completes the following steps for a given batch:

    1. If the smallest Per Sample Volume (ul) value is less than 5, automatically assigns a value of 5 to the Adjusted Per Sample Volume (ul) field of the sample.

    2. Adjusts the Adjusted Per Sample Volume (ul) field value for all other samples in the batch, based on the ratio used to increase the lowest value to 5.

  • Calculates the Total Sample Volume (ul) field value.

    step.::Total Sample Volume (ul):: = step.::Total Sample Volume (ul):: + input.::Adjusted Per Sample Volume (ul)::
  • If the Total Sample Volume is less than the Bulk Pool Volume, this automation calculates the RSB Volume (ul) field value.

    if (step.::Total Sample Volume (ul):: >= step.::Bulk Pool Volume (ul)::) {
        output.::RSB Volume (ul):: = 0
    }
    else {
        output.::RSB Volume (ul):: = step.::Bulk Pool Volume (ul):: - step.::Total Sample Volume (ul)::
    } ;
  • Copies the Flowcell Type and Loading Workflow Type values from the step inputs to the step outputs.

    output.::Flowcell Type:: = input.::Flowcell Type:: ;
    output.::Loading Workflow Type:: = input.::Loading Workflow Type:: ;
  • Sets the Volume of Pool to Denature (ul) value a calculates the NaOH Volume (ul) and Tris-HCl Volume (ul) values based on the Flowcell Type.

    if ( input.::Flowcell Type:: == ::SP:: ) {
        output.::Volume of Pool to Denature (ul):: = 100 ;
        output.::NaOH Volume (ul):: = 25 ;
        output.::Tris-HCl Volume (ul):: = 25
    } ;
    if ( input.::Flowcell Type:: == ::S1:: ) {
        output.::Volume of Pool to Denature (ul):: = 100 ;
        output.::NaOH Volume (ul):: = 25 ;
        output.::Tris-HCl Volume (ul):: = 25
    } ;
    if ( input.::Flowcell Type:: == ::S2:: ) {
        output.::Volume of Pool to Denature (ul):: = 150 ;
        output.::NaOH Volume (ul):: = 37 ;
        output.::Tris-HCl Volume (ul):: = 38
    } ;
    if ( input.::Flowcell Type:: == ::S4:: ) {
        output.::Volume of Pool to Denature (ul):: = 310 ;
        output.::NaOH Volume (ul):: = 77;
        output.::Tris-HCl Volume (ul):: = 78
    }
  • Uses the NovaSeq_Standard_Bulk_Pool1.csv, NovaSeq_Standard_Bulk_Pool2.csv, and NovaSeq_Standard_Bulk_Pool3.csv template files to generate a single CSV file containing information about the pool and the samples it contains. The generated file is available for download in the Files section of the Record Details milestone in the Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2) step.

    && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/DriverFileGenerator.jar -i {stepURI:v2} -u {username} -p {password} -l {compoundOutputFileLuid1} \
    script:driver_file_generator \
    -t /opt/gls/clarity/extensions/conf/driverfiletemplates/NovaSeq_Standard_Bulk_Pool1.csv \
    -o 1.csv \
    script:driver_file_generator \
    -t /opt/gls/clarity/extensions/conf/driverfiletemplates/NovaSeq_Standard_Bulk_Pool2.csv \
    -o 2.csv \
    script:driver_file_generator \
    -t /opt/gls/clarity/extensions/conf/driverfiletemplates/NovaSeq_Standard_Bulk_Pool3.csv \
    -o 3.csv \
    && cat 1.csv 2.csv 3.csv > {compoundOutputFileLuid0}.csv
  • Resets the Total Sample Volume (ul) and Number of Samples in Pool field values so that the automation is idempotent.

    step.::Number of Samples in Pool:: = step.::Number of Samples in Pool:: - 1;
    step.::Total Sample Volume (ul):: = step.::Total Sample Volume (ul):: - input.::Adjusted Per Sample Volume (ul)::
Set Next Step Automation

Automatically triggered on exit of the Record Details screen, the following automation sets the next step for samples to ADVANCE, advancing them to the Dilute and Denature (NovaSeqDx v1.2) step in the protocol:

nextStep = ::ADVANCE::

The following automation copies the NovaSeqDx Run Mode values from the step inputs to the step outputs:

output.::NovaSeqDx Run Mode:: = input.::NovaSeqDx Run Mode::

Master Step Fields

The following fields are defined on the Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2) step.

Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2) Master Step Field Configuration

Field Name

Field Type

Options

Additional Options and Dropdown Items

% PhiX (2.5 nM) Spike-In

Numeric

  • Range = 0–100

Bulk Pool Volume (ul)

ℹ For calculation purposes, not displayed

Numeric

  • Decimal places displayed = 2

Number of Flowcells to Sequence

Numeric

Required Field

  • Range = 1–10

  • Decimal places displayed = 0

Minimum Per Sample Volume (ul)

Numeric

Required Field

  • Decimal places displayed = 2

  • Default

    • 5

Number of Samples in Pool

ℹ For calculation purposes, not displayed

Numeric

  • Decimal places displayed = 0

  • Default

    • 0

PhiX Volume (ul)

ℹ For calculation purposes, not displayed

Numeric

  • Decimal places displayed = 2

Total Sample Volume (ul)

ℹ For calculation purposes, not displayed

Numeric

  • Decimal places displayed = 2

  • Default

    • 0

Global Fields

The following table lists the global custom fields that are configured to display on the Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2) step.

Global Custom Fields Configuration (Derived Sample)

Field Name

Field Type

Options

Additional Options and Dropdown Items

Flowcell Type

Text Dropdown

Required Field

Presets

  • SP

  • S1

  • S2

  • S4

Loading Workflow Type

Text Dropdown

Required Field

Presets

  • NovaSeq Standard

  • NovaSeq Xp

  • [Remove from workflow]

NaOH Volume (ul)

Numeric

Read Only

Decimal places displayed = 2

RSB Volume (ul)

Numeric

Read Only

Decimal places displayed = 2

Tris-HCl Volume (ul)

Numeric

Read Only

Decimal places displayed = 2

Volume of Pool to Denature (ul)

ℹ Used in Make Bulk Pool for NovaSeqDx Standard (NovaSeqDx v1.2) step only. Displays on Record Details screen and in the generated CSV file.

Numeric

Read Only

  • Decimal places displayed = 0

Step 2: Dilute and Denature (NovaSeqDx v1.2)

In this step, the addition of NaOH, Tris-HCl, and Resuspension Buffer (RSB) denatures and dilutes pooled samples. Manually place the pooled samples into the library tube for the NovaSeqDx Run.

In addition, this step validates the run setup information and generates the sample sheet file.

  • Step input: Bulk pool

  • Step output: Library tube

Validate Single Input Automation

Automatically triggered at the beginning of the step, this automation checks that there is only one container input to the step.

script:validateSampleCount -min 1 -max 1
Validate Library Tube Barcode Automation

Automatically triggered on exit of the Placement screen, this automation completes the following actions:

  • Validates the library tube barcode to ensure it conforms to the following barcode masks:

    • DX mode: DX[0-9]{7}-[A-Z]{3}

    • RUO mode: [A-Z]{2}[0-9]{7}-[A-Z]{3}

    if ((input.::NovaSeqDx Run Mode:: == ::DX:: && !output.container.name.matches(::^DX[0-9]{7}-[A-Z]{3}$::)) || (input.::NovaSeqDx Run Mode:: == ::RUO:: && !output.container.name.matches(::[A-Z]{2}[0-9]{7}-[A-Z]{3}::))) {
        fail(::Invalid Library Tube Barcode. Please verify and try again.::)
    }
  • Copies Flowcell Type and Loading Workflow Type field values from step inputs to outputs:

    output.::Flowcell Type:: = input.::Flowcell Type:: ;
    output.::Loading Workflow Type:: = input.::Loading Workflow Type::
Validate Run Setup and Generate Sample Sheet Automation

Triggered by a button on the Record Details screen, this automation completes the following actions:

ℹ The script definition portion of Validate Run Setup has been moved into the Validation Script custom field due to the 4000 character limit. If modification is required on Validate Run Setup script, perform the changes directly on the Validation Script custom field default value.

  • Copies the Flowcell Type from the step input to the Run Mode field (hidden):

    step.::Run Mode:: = input.::Flowcell Type::
    • Experiment Name only contains alphanumeric, dash, or underscore characters. Spaces are not permitted.

    • When Workflow Type = No Index, both Index Read 1 and Index Read 2 must be zero.

    • When Workflow Type = Single Index, Index Read 1 must be greater than zero, and Index Read 2 must be zero.

    • When Workflow Type = Dual Index, both Index Read 1 and Index Read 2 must be greater than zero.

    if(!step.::Experiment Name::.matches(::[a-zA-Z0-9-_]+::)) {
        fail(::Experiment Name contains prohibited characters. Allowed characters are: a-z, A-Z, 0-9, -, and _::)
    };
    if (step.::Workflow Type:: == ::No Index::) {
        if (step.::Index Read 1:: != 0 || step.::Index Read 2:: != 0) {
            fail(::Index Read 1 and Index Read 2 must be 0 if No Index is selected.::)
        }
    } else if (step.::Workflow Type:: == ::Single Index::) {
        if (step.::Index Read 1:: == 0 || step.::Index Read 2:: != 0) {
            fail(::Index Read 1 must be greater than 0 and Index Read 2 must be 0 if Single Index is selected.::)
        }
    } else {
        if (step.::Index Read 1:: == 0 || step.::Index Read 2:: == 0) {
            fail(::Index Read 1 and Index Read 2 must be greater than 0 if Dual Index is selected.::)
        }
    };
  • Checks the Paired End and Read 2 Cycles field values as follows.

    • If Paired End = True, both Read 1 Cycles and Read 2 Cycles must be greater than 0.

    • If Paired End = False, Read 2 Cycles must be zero.

    if (step.::Paired End::.toBoolean()) {
        if (step.::Read 1 Cycles:: == 0 || step.::Read 2 Cycles:: == 0) {
            fail(::Read 1 Cycles and Read 2 Cycles must be greater than 0 if Paired End is True.::)
        }
    } else {
        if (step.::Read 2 Cycles:: != 0) {
            fail(::Read 2 Cycles must be 0 if Paired End is False.::)
        }
    };
  • Checks the Flowcell field value as follows.

    • If Flowcell Type value is not SP, checks that the values of Read 1 Cycles and Read 2 Cycles are each 151 or less. If the value is greater than 151, an error message is generated.

    if (input.::Flowcell Type::!=::SP:: && step.::Read 1 Cycles:: > 151) {
        fail(::Read 1 Cycles must not be larger than 151 if it is not SPrime Flowcell::)
    };
    if (input.::Flowcell Type::!=::SP:: && step.::Read 2 Cycles:: > 151) {
        fail(::Read 2 Cycles must not be larger than 151 if it is not SPrime Flowcell::)
    };
  • Validate Analysis Software Version to ensure it is a valid version string.

    if (step.hasValue(::Analysis Software Version::) && !step.::Analysis Software Version::.matches(::^(\\d+)(\\.\\d+)*$::)) {
        fail(::Analysis Software Version contains prohibited characters. Allowed characters are 0-9 and period. It shall start and end with numbers and separated by single period e.g. 3.8.4::)
    };
  • Validate Override Cycles value to contain only Y, N, I, U, 0-9, and semicolon characters.

    if (step.hasValue(::Override Cycles::) && !step.::Override Cycles::.matches(::[YNIU0-9;]+::)) {
        fail(::Override Cycles ontains prohibited characters. Allowed characters are: Y, N, I, U, 0-9 and ;. Example: N1Y150;I8;I7N1;Y141U10.::)
    };
  • Sets the next step for samples to REMOVE:

    nextStep = ::REMOVE::
  • /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/DriverFileGenerator.jar -i {stepURI:v2} -u {username} -p {password} \
    script:driver_file_generator \
    -t /opt/gls/clarity/extensions/conf/driverfiletemplates/NovaSeqDx_BCL2FASTQ_Samplesheet_v2.csv \
    -o {compoundOutputFileLuid0}.csv \
    -q true \
    -destLIMSID {compoundOutputFileLuid0} \
    -l {compoundOutputFileLuid1}"
Routing Script Automation

Automatically triggered on exit of the step, this automation invokes the changeWorkflow script, which routes step outputs to the NovaSeqDx v1.2 workflow, and queues them for the AUTOMATED - NovaSeqDx Run (NovaSeqDx v1.2) step.

The default automation command line is as follows.

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar
-u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid1} script:changeWorkflow \
--FIELD_NAME 'N/A' \
--FIELD_VALUE 'N/A' \
--WORKFLOW 'NovaSeqDx v1.2' \
--STEP 'AUTOMATED - NovaSeqDx Run (NovaSeqDx v1.2)' \
--INPUTS_OR_OUTPUTS 'OUTPUTS'"

Master Step Fields

The following table lists field configuration details for the fields that are defined on the Dilute and Denature (NovaSeqDx v1.2) step. These fields are required for sample sheet and JSON file generation.

Dilute and Denature (NovaSeqDx v1.2) Master Step Field Configuration

Field Name

Field Type

Options

Additional Options and Dropdown Items

Analysis Software Version

Text

BaseSpace Sequence Hub Configuration

Text Dropdown

  • Required Field

  • Presets

    • Not Used

    • Run Monitoring Only

    • Run Monitoring and Storage