RNA Library Prep v1.1
Last updated
Last updated
Protocol Type = Library Prep
Next Steps Configuration
Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Waiting | Built-in | ||
Project | Project Name | Built-in |
Group of Defaults
Step Data
Group of Defaults = Immune Repertoire Panel
Master Step Fields
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Desired Concentration (ng/uL) | Numeric | Range = 0 To 1000 | |
Directions | Multiline Text | Read Only | Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL. |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | Concentration | Numeric | Required Field | Decimal Places Displayed = 2 |
Derived Sample | Conc. Units | Text | Required Field | |
Derived Sample | Desired Concentration (ng/uL) | Numeric | ||
Derived Sample | Input Amount (ng) | Numeric | Decimal Places Displayed = 0 | |
Derived Sample | Nuclease-free water (uL) | Numeric | Decimal Places Displayed = 2 | |
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Sample Volume (uL) | Numeric | Decimal Places Displayed = 2 | |
Derived Sample | Total Volume (uL) | Numeric | Decimal Places Displayed = 2 |
Master Step Name = Qubit (AmpliSeq for Illumina v1.1)
Step Type = Standard QC
Measurement Generation = Fixed, 1
Naming Convention = {InputItemName}
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Waiting | Built-in | ||
Project | Project Name | Built-in |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Criteria 1 - Operator | Text | Default = >= | |
Criteria 1 - Source Data Field | Text | Default = Concentration | |
Criteria 1 - Threshold Value | Numeric | ||
Criteria 2 - Operator | Text | Default = <= | |
Criteria 2 - Source Data Field | Text | Default = Concentration | |
Criteria 2 - Threshold Value | Numeric |
Step File Placeholders
Log - Automatically attached
QC Log File - Automatically attached
QC Result File - Automatically attached
Upload File - Manually uploaded
Sample Table
Enable QC Flags = Yes
Sample Display Default = Expand
Well Sort Order = Row
File Column Options
File Column Display = Hide
File Attachment Method = Auto
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | Concentration | Numeric | Required Field | Decimal Places Displayed = 2 |
Derived Sample | Conc. Units | Text | Required Field | |
Derived Sample | Sample Name | Built-in | ||
Measurement | Concentration | Numeric | Decimal Places Displayed = 2 | |
Measurement | Conc. Units | Text |
Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Waiting | Built-in | ||
Project | Project Name | Built-in |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Desired Concentration (ng/uL) | Numeric | Range = 0 To 1000 | |
Directions | Multiline Text | Read Only | Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL. |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | Concentration | Numeric | Required Field | Decimal Places Displayed = 2 |
Derived Sample | Conc. Units | Text | Required Field | |
Derived Sample | Input Amount (ng) | Numeric | Decimal Places Displayed = 0 | |
Derived Sample | Nuclease-free water (uL) | Numeric | Decimal Places Displayed = 2 | |
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Sample Volume (uL) | Numeric | Decimal Places Displayed = 2 | |
Derived Sample | Total Volume (uL) | Numeric | Decimal Places Displayed = 2 |
Master Step Name = Reverse Transcribe RNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
AmpliSeq cDNA Synthesis for Illumina
Supplier = Illumina
Catalog Number = 20022654
Website = www.illumina.com
AmpliSeq Focus Panel for RNA
Supplier = Illumina
Catalog Number = 20019164
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Waiting | Built-in | ||
Project | Project Name | Built-in |
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement Pattern = Row
Destination Containers
96 well plate
Group of Defaults
Step Data
Group of Defaults = Focus Panel
Master Step Fields
Field Name | Field Type | Options | Additional Options and Dropdown Items |
5X AmpliSeq cDNA Reaction Mix (uL) | Numeric |
| |
10X AmpliSeq RT Enzyme Mix (uL) | Numeric |
| |
Desired Concentration (ng/uL) | Numeric | Read Only | |
Nuclease-free water (uL) | Numeric |
| |
Prep Input Amount (ng) | Numeric |
| |
Prep Input Volume (uL) | Numeric |
| |
Recommended Prep Input (ng) | Multiline Text | Read Only |
|
Thermal Cycler Program | Text | Read Only |
|
Total Samples | Numeric |
|
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Derived Sample | Concentration | Numeric | Required Field | Decimal Places Displayed = 2 |
Derived Sample | Conc. Units | Text | Required Field | |
Derived Sample | Input Amount (ng) | Numeric | Decimal Places Displayed = 0 | |
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Total Volume (uL) | Numeric | Decimal Places Displayed = 2 |
Master Step Name = Amplify cDNA Targets (AmpliSeq for Illumina Focus Panel v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
AmpliSeq Focus Panel for RNA
Supplier = Illumina
Catalog Number = 20019164
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Waiting | Built-in | ||
Project | Project Name | Built-in |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
5x AmpliSeq Focus Panel (uL) | Numeric | Decimal Places Displayed = 1 | |
5X AmpliSeq HiFi Mix (uL) | Numeric | Decimal Places Displayed = 1 | |
Nuclease-free water (uL) | Numeric | Decimal Places Displayed = 1 | |
PCR Cycles | Numeric | Decimal Places Displayed = 1 | |
Thermal Cycler Program | Text | Default = AMP | |
Total Samples | Numeric | Default = 0 |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Project | Project Name | Built-in |
Master Step Name = Partially Digested Amplicons (AmpliSeq for Illumina Focus Panel v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
AmpliSeq cDNA Synthesis for Illumina
Supplier = Illumina
Catalog Number = 20022654
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Sample Name | Built-in | ||
Derived Sample | Waiting | Built-in | ||
Project | Project Name | Built-in |
Step Data (Master Step Fields)
Field Name | Field Type | Options | Additional Options and Dropdown Items |
Thermal Cycler Program | Text | Default = FUPA |
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Column
Table Columns - Global Fields
Category | Field Name | Field Type | Options | Additional Options and Dropdown Items |
Container | Container Name | Built-in | ||
Container | LIMS ID (Container) | Built-in | ||
Container | Well | Built-in | ||
Derived Sample | Queue for Plate Transfer | Text | Default = Transfer Amplicons | |
Derived Sample | Sample Name | Built-in | ||
Project | Project Name | Built-in |