Common Questions
Q1. My run failed; how can I troubleshoot it?
You can access the "Failed steps details" link to review the ICA Analysis Failed Step Logs:

Q2. Should I trim adapters beforehand?
In the E2E workflow, Truseq Adapter trimming is managed by BCL Convert when using a Run Planner-configured sample sheet (when Illumina miRNA prep is selected). Meanwhile, the DRAGEN miRNA software automatically trims the 3' UMI adapter during its process. If the Truseq Adapter is not trimmed before analysis, it does not affect the actual analysis but alters the final read statistics.
Q3. What are the most common errors?
Sample Names not following Illumina’s name convention
Memory issues at the counting step (fixed during SW verification)
Sample sheet configuration mistakes (best to use BSSH Run Planning)
Q4. Can DRAGEN miRNA be used to analyze TruSeq Small RNA data?
The software was not designed to analyze TruSeq Small RNA and analysis will fail.
Q5. How were reference sequences for small RNAs obtained?
Check the Reference Database page for further information
Q6. What are the software component versions used in DRAGEN miRNA 1.0.0?
Reference database: miRBase v21 and v22 available
Analysis Pipeline Version: 1.0.0
DRAGEN Report Version: 4.5.0-alpha.7
Cutadapt Version: 1.10
Bowtie Version: 1.1.2
Q7. What species will the analysis support?
Supports the following species:
Human
Mouse
Rat
Zebrafish
Nematode
Fruitfly
MiRNA references are based upon the version v21 and v22 of the miRBase, customers can choose between the two versions when running an analysis
Q8. How do I demultiplex my samples?
One can use the BCLConvert app available in BSSH. Check the following page for further information: https://www.illumina.com/products/by-type/informatics-products/basespace-sequence-hub/apps/bcl-convert.html
Last updated
Was this helpful?