LogoLogo
Illumina KnowledgeIllumina SupportSign In
DRAGEN Protein Quantification
  • Home
DRAGEN Protein Quantification
  • Get Started
    • Introduction
    • Prerequisites
      • Illumina Protein Prep Automation System Output Files
  • Run Setup
    • Run Planning with the BSSH Run Planner Tool
    • Sample Sheet Fields
    • Local Sample Sheet Generation Tool
    • Lane Splitting and Multi-Analysis by Project
  • Counting and Normalization
    • Cloud Autolaunch Secondary Analysis
      • Accessing Cloud Results
    • Local Secondary Analysis
    • Normalization Summary
    • QC Summary
    • Interpretation of Results
    • Metrics Appendix
  • Output Files
    • Output Structure
    • DRAGEN Report
    • ADAT Content
  • After Counting and Normalization
    • Using the ADAT
    • Illumina Connected Multiomics Walkthrough
  • References
    • FAQs
    • Documentation Revision History
Powered by GitBook
On this page
  • DRAGEN Protein Quantification Application
  • Setting Up Autolaunch on Sequencing Instrument
  • Manually Kicking Off Secondary Analysis
  • Requeue

Was this helpful?

Export as PDF
  1. Counting and Normalization

Cloud Autolaunch Secondary Analysis

PreviousLane Splitting and Multi-Analysis by ProjectNextAccessing Cloud Results

Last updated 1 month ago

Was this helpful?

DRAGEN Protein Quantification Application

The DRAGEN Protein Quantification application is designed to perform counting and normalization for proteomics data from the Illumina Protein Prep pipeline. It converts data from the binary base call (BCL) files, generated by Illumina NovaSeq 6000 or NovaSeq X Series systems, into the normalized proteomic counts. Upon completion of sequencing, the application is automatically initiated for analysis on BaseSpace Sequence Hub (BSSH) or Illumina Connected Analytics (ICA).

The sections below exemplify how to configure the instrument(s) for autolaunching the secondary analysis, manually initiate an analysis, and requeue an analysis.

Setting Up Autolaunch on Sequencing Instrument

  1. On your instrument, log into your workgroup and select the following run setup options:

    1. Workflow: NovaSeq Standard

    2. Read length: 15, 10, 10, 0

  2. [NovaSeq 6000] Upload the v2 sample sheet generated by the BSSH Run Planner tool to the sequencing instrument.

  3. [NovaSeq X Series] No action is required. The v2 sample sheet automatically displays on the instrument as a planned run.

  4. Select the appropriate Illumina Protein Prep custom recipe for your sequencing instrument and flowcell. During the run, data is uploaded automatically to BSSH. Primary analysis and secondary analysis are completed automatically through autolaunch.

  5. [Optional] Use the BaseSpace Sequence Hub to monitor the run from start to completion.

For additional information on autolaunch, refer to the page.

Manually Kicking Off Secondary Analysis

If manual mode sequencing is performed, or autolaunch is unsuccessful, there is an option to manually upload a completed run folder to BSSH and kick off the autolaunch analysis. To use this method, the samplesheet must be in the uploaded run folder, and be named "SampleSheet.csv".

Requeue

Follow the instructions from the for to BSSH.

Follow the instructions described in .

Cloud Analysis Auto-launch
BSSH CLI documentation
manually uploading the run folder
Requeue Analysis Page (Requeue Analysis in BaseSpace tab)