The default mode of the small variant caller has been optimized to detect germline variants with typical AFs of 0%, 50% or 100%. On the other hand, non-cancer post-zygotic mosaic variants have typical allele frequencies (AFs) lower than 50% and therefore more challenging to find with the default small variant caller. To improve sensitivity of low AF calls, a new machine learning (ML) model trained using read and context evidence from low AF calls is used. This allows the model to identify variants down to approximately 5% AF on 35x WGS and 3% AF on 300x WGS. The mosaic ML model is applied to all calls that are rejected by the germline model and variants detected with the mosaic detection are ideintified by a MOSAIC
flag in the VCF INFO field.
When the mosaic detection is enabled, the hard filter QUAL
threshold for both SNPs and INDELs is lowered to 0.4
in this mode to allow low AF calls to be set as PASS
in the FILTER field. MOSAIC
tagged variants with QUAL
smaller than 3
are filtered with the MosaicHardQUAL
filter.
We provide an optional MosaicLowAF
filtering option to filter MOSAIC
tagged variants with AF
smaller than the AF
threshold. The threshold for this filter can be set with the --vc-mosaic-af-filter-threshold
option.
Furthermore, the output of MOSAIC
tagged calls can be restricted using an optional target BED provided with the --vc-mosaic-target-bed
option.
--vc-enable-mosaic-detection
Set to true to enable mosaic detection with mosaic AF filter threshold set to 0.0
. Set to false to disable mosaic detection. The default is true with mosaic AF filter threshold set to 0.2
.
--vc-mosaic-af-filter-threshold
Set the allele frequency threshold for the application of the MosaicLowAF
filter to mosaic calls. All MOSAIC
tagged variants with AF
smaller than the AF
threshold are filtered with the MosaicLowAF
filter. The default mosaic AF
filter threshold is set to 0.2
when the germline variant caller is enabled. The AF default threshold is set to 0.0
when the mosaic detection mode is enabled with --vc-enable-mosaic-detection=true
.
--vc-mosaic-qual-filter-threshold
Set the QUAL
threshold for the application of the MosaicHardQUAL
filter to mosaic calls. All MOSAIC
tagged variants with QUAL
smaller than the threshold QUAL
are filtered with the MosaicHardQUAL
filter. The default mosaic QUAL
filter threshold is set to 3.0
.
--vc-mosaic-target-bed
Optional target BED file to restrict the output of MOSAIC
tagged variant calls only in the specified regions.
Small variant calling features comparison between default germline small variant caller and mosaic detection mode in DRAGEN 4.2 and DRAGEN 4.3
Tag | Name | Command line options | QUAL threshold | MAPQ0 | Mosaic Detection | Mosaic AF filter threshold |
---|---|---|---|---|---|---|
4.2 | DRAGEN 4.2 default Small Variant Caller | --enable-variant-caller=true | 3 | No | No | N/A |
4.2 HSM | DRAGEN 4.2 High Sensitivity Mode | --enable-variant-caller=true --vc-enable-high-sensitivity-mode=true | 0.4 | Yes | Yes (Alpha) | N/A |
4.3 | DRAGEN 4.3 default Small Variant Caller | --enable-variant-caller=true | 3 | Yes | Yes (Full) | 20% |
4.3 Mosaic | DRAGEN 4.3 Mosaic Detection Mode | --enable-variant-caller=true --vc-enable-mosaic-detection=true | 0.4 | Yes | Yes (Full) | 0% |