LogoLogo
Illumina KnowledgeIllumina SupportSign In
  • Home
  • Get Started
    • Overview
    • Typical user actions
  • Installation (Connected Insights - Local)
    • Overview
    • Prerequisites
    • Install Connected Insights Software
    • Install Illumina Connected Annotations
    • Install License File
    • Sign In to Connected Insights
    • Install Knowledge Bases
    • Installation Status Messages
  • Configuration
    • Overview
    • Automation
    • Custom Actionability Classification
    • Custom Annotations
    • Custom Case Data Definition
    • Disease Configuration
    • Test Definition Setup
    • Variant Flag Groups
    • Variant Filters
    • Preferred Transcripts
    • Pipeline and QC Configuration
    • Reports
      • Templates
      • Customizations
  • APIs
    • Overview
    • Case APIs
    • Ingest Cloud Analysis Data API (Connected Insights - Cloud Only)
    • Report APIs
    • Audit Log APIs
  • Data Upload
    • Overview
    • Data Upload from User Storage (Connected Insights - Cloud and Connected Insights - Local)
    • Data Upload from ICA (Connected Insights - Cloud)
    • Custom Pipeline Configuration
      • VCF Input Requirement
    • Custom Case Data Upload
    • Assertions Upload
  • Case Management
    • Overview
    • Cases List
    • Case Metada Upload
    • Case Details
      • Merge Cases
    • Overview Tab
    • Visualize Tab
    • Lab QC Tab
    • Report Tab
  • Interpretation
    • Overview
    • Variant Grid
    • Modify Variant Grid
    • IGV Visualizations
    • Transcripts
    • Apply Variant Filters
      • Filter by Variant Category
      • Variant Details Filters
      • Variant Quality Filters
      • Functional Impact Filters
      • Disease Association Filters
      • Variant Frequency Filters
      • Flags Filter
      • Filtering Logic
    • View Variant Details
      • Biological Classification
      • Actionability
      • Clinical Trials
      • Oncogenicity Prediction
      • Visualize
      • Variant Overview
      • Gene Overview
      • Cancer Data Sets
      • Computer Predictors
      • Population
    • Interpret a Variant
    • Edit, Remove, and Archive Assertions
  • Reports
    • Overview
  • Usage
    • Overview
  • Administration
    • Overview
    • Administration Console (Connected Insights - Local)
  • Troubleshooting
    • Overview
    • Data Backup (Connected Insights - Local)
    • Software Errors and Corrective Actions
  • Resources and References
    • Overview
    • Acronyms and Terms
    • Release Notes
  • Technical Assistance
    • Overview
Powered by GitBook
On this page
  • Create a Report Template
  • Download Report Template
  • Test Changes After Report Template Customization

Was this helpful?

Export as PDF
  1. Configuration
  2. Reports

Templates

Connected Insights requires you to provide a report template for each test definition to ensure consistency of reports produced across cases. This section summarizes the actions that can be performed with report templates to customize the look and content of PDF reports to your specifications.

  • Create several report templates and use them in more than one test definition.

  • Use the default report template provided by Connected Insights or customize the report as needed. These customizations include: – Changing the logo of the laboratory. – Changing the report name. – Reformatting the page and date. – Removing parts of the report related to the Nothing Reported section. This modification might be needed if the laboratory prefers not to report pertinent negatives. – Adding sample information alongside case and subject information. – Changing text in the Supplemental Information section.

For more information on the customization options, refer to Report Customizations.

Create a Report Template

  1. On the top toolbar, select Configuration, and then select the Test Components tab.

  2. Navigate to Report Templates and select New.

  3. Select Download the template.

  4. Save the base ODT template.

  5. Edit the file with an applicable document editor. The document editor must be able to load v1.3 ODT files. For information on making custom edits to the report, refer to Report Customizations.

  6. Select Upload template to re-upload the template with the recently made changes. Uploaded files must in the ODT format.

  7. Select Confirm Report Creation when the report preview displays. Download the original report in the ODT format at any time. You can also archive and unarchive report templates. Archiving a report template makes it unavailable for use when creating a test definition.

Download Report Template

  1. On the top toolbar, select Configuration, and then select the Test Components tab.

  2. Select Report Templates, and then select Pre-configured Demo Report Template.

  3. After the report loads, select Download as ODT.

Test Changes After Report Template Customization

  1. On the top toolbar, select Configuration, and then select the Test Components tab.

  2. Navigate to Report Templates and select New.

  3. For Create your new report, select Upload template.

  4. Using file explorer, navigate to the template with the changes and select Open.

  5. Review the PDF preview to make sure that the modified report displays as intended.

PreviousReportsNextCustomizations

Last updated 1 year ago

Was this helpful?