LogoLogo
Illumina KnowledgeIllumina SupportSign In
  • Home
  • Welcome
  • Account Management
    • Software Setup
      • FAQ
    • Platform Home
    • Admin Console
      • Workgroups
      • Domain
    • Usage Explorer
  • Custom Design
    • Custom Design Products
  • Lab Management
    • Lab Management Products
  • Run Set Up
    • Run Set Up Products
    • Run Workflows
    • Sample Sheet
      • Sample Sheet Structure
        • Section Requirements
        • BCL Convert Interactive Sample Sheet
      • Intrument Settings
        • NovaSeq X Settings
          • NovaSeq X Sample Sheet Version History
        • NextSeq 1000/2000 Settings
          • NextSeq 1000/2000 Sample Sheet Version History
      • Cloud Analysis Auto-launch Settings
      • Index Orientation Guide
        • i5 Index Orientation Table
      • Resources
        • BCL Convert Parameter Usage
        • Illumina Knowledge Help
    • MiSeq: Run Set Up
  • Analysis
    • Analysis Products
    • Cloud Analysis Auto-launch
    • Sequencer Auto-launch Analyses Compatibility
  • Interpretation
    • Interpretation Products
  • Cross-Product Tutorials
    • NovaSeq X: BCL Convert Auto-launch Analysis in Cloud
    • NovaSeq 6000: BCL Convert Auto-launch Analysis in Cloud
    • NovaSeq 6000Dx: TSO 500 Auto-launch Analysis in Cloud
    • MiSeq: DRAGEN Amplicon and Connected Insights Auto-launch Analysis in Cloud
    • NextSeq 550/550Dx: TSO 500 and Connected Insights Auto-launch Analysis in Cloud
  • Reference
    • Software Release Notes
    • Documentation Revision History
Powered by GitBook
On this page
  • Cloud Orchestrated Cloud Analysis
  • Cloud Orchestrated Local Analysis
  • Locally Orchestrated Local Analysis
  • Manual Run with Sample Sheet Based Local Analysis

Was this helpful?

Export as PDF
  1. Run Set Up

Run Workflows

Cloud Orchestrated Cloud Analysis

The Cloud Orchestrated Cloud Analysis workflow streamlines sequencing run planning and cloud-based secondary analysis using the BaseSpace Sequence Hub Run Planning interface. With Cloud Orchestrated Cloud Analysis, you can plan a sequencing run for a specific instrument platform and configure the associated cloud secondary analysis using the BaseSpace Sequence Hub Run Planning interface. Once the run has been planned, any instrument of that platform can access and kick off the run, provided you log into the instrument using the same workgroup context as the run was planned in.

Sequencing runs using this workflow require you to upload your run data to BaseSpace Sequence Hub so that it can be used to run the associated secondary analysis.

Once the sequencing run is complete and all primary analysis data has been uploaded to BaseSpace Sequence Hub, the secondary analysis is automatically kicked off in the cloud and linked to the run in BaseSpace Sequence Hub.

Current instrument platforms that support Cloud Orchestrated Cloud Analysis:

  • NextSeq 1000 / NextSeq 2000

  • NovaSeq X Series

  • MiSeq i100 Series


Cloud Orchestrated Local Analysis

The Cloud Orchestrated Local Analysis workflow enables you to plan your sequencing run (associated with a specific instrument platform) and the associated on-instrument secondary analysis using the BaseSpace Sequence Hub Run Planning interface. Once the run has been planned, any instrument of that platform can access and kick off the run, provided you log into the instrument using the same workgroup context as the run was planned in.

Sequencing runs using the Cloud Orchestrated Local Analysis workflow require you to send at least run monitoring data to BaseSpace Sequence Hub so that the run planned in the cloud can be kept in sync with the instrument.

Once the sequencing run is complete and all primary analysis data has been generated, the secondary analysis is automatically kicked off on the instrument as specified by the user during run planning.

Current instrument platforms that support Cloud Orchestrated Local Analysis:

  • NextSeq 1000 / NextSeq 2000

  • MiSeq i100 Series


Locally Orchestrated Local Analysis

The Locally Orchestrated Local Analysis workflow enables you to plan a sequencing run and associated on-instrument secondary analysis using the on-instrument Run Planning interface. Once the run has been planned, any user can access and kick off the run upon logging into the instrument.

Once the sequencing run is complete and all primary analysis data has been generated, the secondary analysis is automatically launched on the instrument, as specified by the user during run planning.

Sequencing runs using the Locally Orchestrated Local Analysis workflow enable you to use any level of cloud connectivity and data upload. On NovaSeq X Series or MiSeq i100 Series instruments, you can also optionally upload FastQ and BAM/CRAM files to the cloud if desired.

Current instrument platforms that support Locally Orchestrated Local Analysis:

  • NovaSeq X Series

  • MiSeq i100 Series


Manual Run with Sample Sheet Based Local Analysis

The Sample Sheet Driven Local Analysis workflow leverages DRAGEN on the instrument, relying on a sample sheet to provide the necessary details for orchestrating and executing the analysis directly onboard. In order to use this workflow, select the option when setting up a run to perform local analysis using a sample sheet, and attach the desired sample sheet to your run.

When using this workflow, the DRAGEN analysis is started onboard automatically when the sequencing data is in a ready state to begin analysis.

For optimal results, it is recommended to generate the initial sample sheet using the BaseSpace Sequence Hub Run Planning interface for local analysis. This will ensure proper formatting and acceptable values for all fields.

Current instrument platforms that support Sample Sheet Driven Local Analysis:

  • NextSeq 1000 / NextSeq 2000

  • NovaSeqX Series

  • MiSeq i100 Series

PreviousRun Set Up ProductsNextSample Sheet