DNA Library Prep v1.1
Overview
The DNA Library Prep AmpliSeq for Illumina Comprehensive Panel v3 is part of the AmpliSeq for Illumina Comprehensive Panel protocols that include the following functionality:
Preconfigured AmpliSeq for Illumina Comprehensive Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of genomic DNA or total RNA using the AmpliSeq for Illumina workflow.
Automated calculation of sample and buffer volumes.
Automated calculation or display of reagents at every step in the protocol.
Automatic step transition when required.
Automatic placement of samples when necessary.Automated assignment of QC Pass/Fail, based on user-selected threshold values.
Protocol 1: DNA Library Prep (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
Protocol Type = Library Prep
Next Steps Configuration
Step 1: Dilute DNA (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
Master Step Name = Dilute DNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Automations
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Desired Concentration (ng/uL)
Numeric
Range = 20 To 50
Decimal Places Displayed = 0
Directions
Multiline Text
Read Only
Default = If enough DNA is available, dilute to intermediate concentration of ~20-50 ng/uL.
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Input Amount (ng)
Numeric
Decimal Places Displayed = 0
Derived Sample
Low TE (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Sample Name
Built-in
Derived Sample
Sample Volume (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Total Volume (uL)
Numeric
Decimal Places Displayed = 2
Step 2: Qubit (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
Master Step Name = Qubit (AmpliSeq for Illumina v1.1)
Step Type = Standard QC
Measurement Generation = Fixed, 1
Naming Convention = {InputItemName}
Automations
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Criteria 1 - Operator
Text
Default = >=
Criteria 1 - Source Data Field
Text
Default = Concentration
Criteria 1 - Threshold Value
Numeric
Criteria 2 - Operator
Text
Default = <=
Criteria 2 - Source Data Field
Text
Default = Concentration
Criteria 2 - Threshold Value
Numeric
Step File Placeholders
Log - Automatically attached
QC Log File - Automatically attached
QC Result File - Automatically attached
Upload File - Manually uploaded
Sample Table
Enable QC Flags = Yes
Sample Display Default = Expand
Well Sort Order = Row
File Column Options
File Column Display = Hide
File Attachment Method = Auto
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Sample Name
Built-in
Measurement
Concentration
Numeric
Decimal Places Displayed = 2
Measurement
Conc. Units
Text
Step 3: Dilute DNA Final Concentration (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
Master Step Name = Dilute DNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Automations
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Desired Concentration (ng/uL)
Numeric
Range = 20 To 50
Decimal Places Displayed = 0
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Input Amount (ng)
Numeric
Decimal Places Displayed = 0
Derived Sample
Low TE (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Sample Name
Built-in
Derived Sample
Sample Volume (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Total Volume (uL)
Numeric
Decimal Places Displayed = 2
Step 4: Amplify Targets (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
Master Step Name = Amplify Targets with 2 replicates (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
AmpliSeq Comprehensive Panel v3 for Illumina
Supplier = Illumina
Catalog Number = 20019109
Website = www.illumina.com
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Automations
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Record Details
Group of Defaults
Step Data
Group of Defaults = Comprehensive Panel v3
Master Step Fields
Field Name
Field Type
Options
Additional Options and Dropdown Items
20x AmpliSeq Sample ID Panel For Illumina
Toggle Switch
Default = None Set
20x AmpliSeq Sample ID Panel For Illumina Lot#
Text
PCR Cycles
Numeric
Decimal Places Displayed = 0
Recommended Prep Input (ng)
Multiline Text
Read Only
Default = This protocol supports 1-100 ng per pool. The recommended input is 10 ng high-quality DNA per pool.
Thermal Cycler Program
Text
Default = AMP_DNA
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
5X AmpliSeq HiFi Mix (uL)
Numeric
Decimal Places Displayed = 1
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Input Amount (ng)
Numeric
Decimal Places Displayed = 0
Derived Sample
Nuclease-free water (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Prep Input Amount (ng)
Numeric
Required Field
Range = 2 To 200
Decimal Places Displayed = 0
Derived Sample
Prep Input Volume (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Sample Name
Built-in
Derived Sample
Total Volume (uL)
Numeric
Decimal Places Displayed = 2
Project
Project Name
Built-in
Step 5: Partially Digested Amplicons (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
Master Step Name = Partially Digested Amplicons with Pooling (AmpliSeq for Illumina v1.1)
Step Type = Pooling
Aliquot Generation = Fixed, 1
Naming Convention = {PoolName}
Reagent Kits
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Automations
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Pooling
Label Uniqueness = Off
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement = Enabled
Defaults
Well Sort Order = Row
Placement Pattern = Column
Destination Containers
96 well plate
Record Details
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
Step 6: Transfer RNA and DNA Amplicons (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
Master Step Name = Transfer RNA and DNA Amplicons (AmpliSeq for Illumina)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Automations
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Placement = Enabled
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement Pattern = Column
Destination Containers
96 well plate
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
LIMS ID (Process)
Built-in
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
Step 7: Ligate Indexes (AmpliSeq for Illumina Comprehensive Panel v3 v1.1)
Master Step Name = Ligate Indexes (AmpliSeq for Illumina v1.1)
Step Type = Add Labels
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Automations
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Placement = Enabled
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement Pattern = Column
Destination Containers
96 well plate
Add Labels
Label Groups
AmpliSeq CD Indexes Set A for Illumina
AmpliSeq CD Indexes Set B for Illumina
AmpliSeq CD Indexes Set C for Illumina
AmpliSeq CD Indexes Set D for Illumina
AmpliSeq UD Indexes for Illumina (24 Indexes)
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Thermal Cycler Program
Text
Default = LIGATE
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
AmpliSeq Workflow
Text Dropdown
Required Field
Preset
Standard Workflow
Equalizer Workflow
Derived Sample
Sample Name
Built-in
Last updated