To follow this tutorial, download the 32 .idat files (note that two .idat files are generated for each array) and unzip them on your local computer using 7-zip, WinRAR, or a similar program. The .idat files can be downloaded in a zipped folder using this link - Differential Methylation Analysis data set.
Store the 32 .idat files at C:\Partek Training Data\Methylation or to a directory of your choosing. We recommend creating a dedicated folder for the tutorial
Go to the Workflows drop down list, select Methylation (Figure 1)
Figure 1. Selecting the methylation workflow
Select Microarray Loci Methylation from the Methylation sub-workflows panel (Figure 2)
Figure 2. Selecting the Illumina BeadArray Methylation workflow
That will open Illumina BeadArray Methylation workflow (Figure 3)
Figure 3. Illumina BeadArray Methylation workflow
Select Import Illumina Methylation Data to bring up the Load Methylation Data dialog
Select Import human methylation 450/850 .idat files (Figure 4)
Figure 4. Selecting human methylation 450/850 .idat file type for import
Select OK
Select Browse... to navigate to the folder where you stored the .idat files
All .idat files in the folder will be selected by default (Figure 5).
Figure 5. Selecting .idat files to import
Select Add File(s) > to move the files to the idat Files to Process pane of the Import Illumina iDAT Data dialog (Figure 6)
Figure 6. Confirming selection of .idat files for import
Select Next >
The following dialog (Figure 7) deals with the manifest file, i.e. probe annotation file. If a manifest file is not present locally, it will be downloaded in the Microarray libraries directory automatically. The download will take place in the background, with no particular message on the screen and it may take a few minutes, depending on the internet connection. In the future, you may want to reanalyze a data set using the same version of the manifest file used during the initial analysis, rather than downloading an up-to-date version. To facilitate this, the Manual specify option in the Manifest File section allows you to specify a specific version. For this tutorial, we will leave this on the default settings.
Figure 7. Selecting manifest file and output file
By default the output file destination is set to the file containing your .idat files and the name matches the file folder name. The name and location of the output file can be changed using the Output File panel.
Select Customize to view advanced options for data normalization
In the Algorithm tab of the Advanced Import Options dialog (Figure 8), there are two filtering options and five normalization options available. The filters allow you to exclude probes from the X and Y chromosomes or based on detection p-value. In this tutorial, we have male and female samples, so we will apply the X and Y chromosome Filter. We will also filter probes based on detection p-value to exclude low-quality probes.
Select Exclude X and Y Chromosomes
Analysis of differentially methylated loci in humans and mice often excludes probes on the X and Y chromosomes because of the difficulties caused by the inactivation of one X chromosome in female samples.
Select Exclude probes using detection p-value and leave the default settings of 0.05 and 1 out of 16 samples.
Figure 8. Advanced Import Options offers choice of normalization method and additional data outputs
Select OK to close the Advanced Import Options dialog
Select Import on the Import Illumina iDAT data dialog
The imported and normalized data will appear as a spreadsheet 1 (Methylation Tutorial) (Figure 9)
Figure 9. Viewing the imported methylation data in a spreadsheet
If you need additional assistance, please visit our support page to submit a help ticket or find phone numbers for regional support.
We recommend using the default option for normalization; however, advanced users can select their preferred normalization method. Select the () next to each normalization option for details. If you want to import probe intensity, raw probe intensity, probe signals, raw probe signals, or anti-log probe intensity values, they can be added to the data import using the Outputs tab of the Advanced Import Options dialog. Probe intensities and raw probe intensities can be used for advanced troubleshooting purposes and antilog probe intensities can be used for copy number detection. The Outputs tab of the Advanced Import Options dialog also has an option to create NCBI GEO submission spreadsheets from your imported data. For this tutorial, we do not need to import any of these values or create GEO submission spreadsheets.